Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Gas-Liquid Separator Modified on CV-AAS System for Determination of Total Hg in the Industrial Wastewater Samples

Molekul: Jurnal Ilmiah Kimia · Vol. 17 No. 3 (2022) · hlm. 292–300

DOI
10.20884/1.jm.2022.17.3.5039
ISSN
2503-0310, 1907-9761
Terbit
2022-11-18
Penerbit
Universitas Jenderal Soedirman
Bahasa
eng

Abstrak

The research about the utilization of modified gas-liquid separators in the determination of Hg ions by using the Cold Vapor Atomic Absorption Spectrophotometer (CV-AAS) method has been done. To optimize the measurement results, several parameters that affect the hydride generator have been studied. Some specified essential parameters are the type and concentration of acid, the level of SnCl2 as a reducing agent, sample volume and the analytical performance such as linearity (r), detection limit (LOD) and quantitation limit (LOQ), repeatability (% RSD), and accuracy have been studied. The results of the research showed the gas-liquid separator modified can be used instead of commercial gas- liquid separators. It was showed by the repeatability value as % RSD < 2/3 CV Horwitz values, the LOD was 0.2530 μg/mL, and the LOQ was 0.8432 μg/mL. The accuracy of this method was good shown by a recovery percentage of 101.6%. Based on the result of this research, the modified of gas-liquid separator can be used for the determination https://www.adenomyosisadviceassociation.org/hysterectomy of Hg ions by using the CV-AAS method with valid results

Jaringan kolaborasi para penulis

25 penulis · 98 tautan kepenulisan bersama · 61 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mulawarman University
  • State University of Malang
  • Xiamen University Malaysia
  • University of Technology Malaysia
  • Universiti Teknologi MARA
  • Universitas Islam Negeri Maulana Malik Ibrahim
  • University of Brawijaya
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mukhamad NurhadiMulawarman University4
Sin Yuan LaiXiamen University Malaysia4
Hadi NurUniversity of Technology Malaysia3
Ratna KusumawardaniMulawarman University2
Nabila Nur AgustiMulawarman University2
Wirhanuddin WirhanuddinMulawarman University2
Wirdhaningsih WirdhaningsihMulawarman University2
Saodah OmarUniversiti Teknologi MARA1
Aripriharta AriprihartaState University of Malang1
Mohamad Rodhi FaizState University of Malang1
Muhammad Adib AminState University of Malang1
Muhammad Cahyo BagaskoroState University of Malang1
Suhiro Wongso SusiloState University of Malang1
Anton PrasetyoUniversitas Islam Negeri Maulana Malik Ibrahim1
Nazarudin NazarudinUniversitas Jambi1
Soerja KoesnarpadiMulawarman University1
Yuniar Ponco PranantoUniversity of Brawijaya1
Volkan DegirmenciUniversity of Warwick1
Sumari SumariState University of Malang1
Agung RahmadaniMulawarman University1
Hadi NurState University of Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Gas-Liquid Separator Modified on CV-AAS System for Determination of Total Hg in the Industrial Wastewater Samples</dc:title>
	<dc:creator>Sujito, Sujito</dc:creator>
	<dc:creator>Pasaribu, Subur P</dc:creator>
	<dc:creator>Wirawan, Teguh</dc:creator>
	<dc:creator>Panggabean, Aman Sentosa</dc:creator>
	<dc:description xml:lang="en-US">


The research about the utilization of modified gas-liquid separators in the determination of Hg ions by using the Cold Vapor Atomic Absorption Spectrophotometer (CV-AAS) method has been done. To optimize the measurement results, several parameters that affect the hydride generator have been studied. Some specified essential parameters are the type and concentration of acid, the level of SnCl2 as a reducing agent, sample volume and the analytical performance such as linearity (r), detection limit (LOD) and quantitation limit (LOQ), repeatability (% RSD), and accuracy have been studied. The results of the research showed the gas-liquid separator modified can be used instead of commercial gas- liquid separators. It was showed by the repeatability value as % RSD &amp;lt; 2/3 CV Horwitz values, the LOD was 0.2530 μg/mL, and the LOQ was 0.8432 μg/mL. The accuracy of this method was good shown by a recovery percentage of 101.6%. Based on the result of this research, the modified of gas-liquid separator can be used for the determination https://www.adenomyosisadviceassociation.org/hysterectomy&amp;nbsp;of Hg ions by using the CV-AAS method with valid results


</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2022-11-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/5039</dc:identifier>
	<dc:identifier>10.20884/1.jm.2022.17.3.5039</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 17 No 3 (2022); 292-300</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/5039/3443</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Molekul</dc:rights>
</oai_dc:dc>