Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Voltammetric Determination of Paracetamol with Carbon Paste Electrode Modified with Molecularly Imprinted Electropolymer

Molekul: Jurnal Ilmiah Kimia · Vol. 17 No. 1 (2022) · hlm. 30–38

DOI
10.20884/1.jm.2022.17.1.5595
ISSN
2503-0310, 1907-9761
Terbit
2022-03-13
Penerbit
Universitas Jenderal Soedirman
Bahasa
eng

Abstrak

Paracetamol is a commom analgesic and antipyretic drug which used for reliefing fever and head ache. The determination of paracetamol dose in pharmaceuticals is very important, becauce an overdose can cause fulminating hepatic necrosis and other toxic effects. Therefore, it is necessary to measure the dose of paracetamol for the patient with precision to avoid harm. Many analytical methodologies have been proposed for determination of paracetamol dose. One of the methods was developed in the past two decades. Generally, electroanalytical approach especially voltammetry method is particularly design for determination of paracetamol dose especially in modifying electrode. This study aims to modified carbon paste electrode with molecularly imprinted polymer (MIP). Significant advantages of using MIP are the superior stability, low cost and ease of preparation. The poly (3-aminiophenol) film was prepared by cyclic voltammetry method and 3-aminophenol monomer in supporting electrolyte (HClO4) with and whitout presence of paracetamol molecule. The effect of paracetamol was seen at cyclic voltammogram was founded, where oxidation peak potential of poly (3-aminophenol) shifted to more cathodic potentials from 0.948 to 0.780 V, in presence of paracetamol. The Ipa showed a good linear relationship with concentration in the range 0.01–0.1 mM, and the detection limit was 4,63 μM.

Jaringan kolaborasi para penulis

6 penulis · 10 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Universitas Bali Internasional
  • Universitas Gadjah Mada
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Buchari BuchariBandung Institute of Technology3
Suryo GandasasmitaBandung Institute of Technology3
Adhitasari SuratmanUniversitas Gadjah Mada2
Abdul Haris WatoniBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Voltammetric Determination of Paracetamol with Carbon Paste Electrode Modified with Molecularly Imprinted Electropolymer</dc:title>
	<dc:creator>Aryasa, I Wayan Tanjung</dc:creator>
	<dc:creator>Noviandri, Indra</dc:creator>
	<dc:description xml:lang="en-US">Paracetamol is a commom analgesic and antipyretic drug which used for reliefing fever and head ache. The determination of paracetamol dose in pharmaceuticals is very important, becauce an overdose can cause fulminating hepatic necrosis and other toxic effects. Therefore, it is necessary to measure the dose of paracetamol for the patient with precision to avoid harm. Many analytical methodologies have been proposed for determination of paracetamol dose. One of the methods was developed in the past two decades. Generally, electroanalytical approach especially voltammetry method is particularly design for determination of paracetamol dose especially in modifying electrode. This study aims to modified carbon paste electrode with molecularly imprinted polymer (MIP). Significant advantages of using MIP are the superior stability, low cost and ease of preparation. The poly (3-aminiophenol) film was prepared by cyclic voltammetry method and 3-aminophenol monomer in supporting electrolyte (HClO4) with and whitout presence of paracetamol molecule. The effect of paracetamol was seen at cyclic voltammogram was founded, where oxidation peak potential of poly (3-aminophenol) shifted to more cathodic potentials from 0.948 to 0.780 V, in presence of paracetamol. The Ipa showed a good linear relationship with concentration in the range 0.01–0.1 mM, and the detection limit was 4,63 μM.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2022-03-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/5595</dc:identifier>
	<dc:identifier>10.20884/1.jm.2022.17.1.5595</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 17 No 1 (2022); 30-38</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/5595/2816</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Molekul</dc:rights>
	<dc:rights xml:lang="en-US">http://jos.unsoed.ac.id/index.php/jm/index</dc:rights>
</oai_dc:dc>