Abstrak

ABSTRACT. Analytical method development ensures that an analytical procedure is suitable for the identification and quantification of compounds of interest. This study aimed to develop and validate a simple, cost-effective analytical method for the determination of zerumbone using UV-Vis spectrophotometry. Method validation was conducted according to ICH Q2(R2) guidelines, including tests for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision. Zerumbone exhibited a maximum absorption wavelength (λmax) of 212 nm when dissolved in dimethyl sulfoxide (DMSO). The method demonstrated excellent linearity with a determination coefficient (R2) of 0.9991 across a concentration range of 10-50 μg/mL. Accuracy, evaluated via recovery studies, ranged from 91,00% to 110,45%. Precision testing results in a % RSD of 0.58%. The calculated LOD and LOQ were 1.55 μg/mL and 4.70 μg/mL, respectively. This validated method is simple, rapid, and economical, making it a promising alternative for zerumbone analysis in quality control laboratories. Keywords: Zerumbone, Method Development, UV-Vis Spectrophotometry, Validation, ICH Guidelines.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Islam Negeri Alauddin Makassar
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Development and Validation of Zerumbone Analysis Method Using Ultraviolet-Visible Spectrophotometry</dc:title>
	<dc:creator>Doloking, Haeria</dc:creator>
	<dc:creator>Muhlisuddin, Muhlisuddin</dc:creator>
	<dc:creator>Maddeppungeng, Nurul Muhlisah</dc:creator>
	<dc:description xml:lang="en-US">ABSTRACT. Analytical method development ensures that an analytical procedure is suitable for the identification and quantification of compounds of interest. This study aimed to develop and validate a simple, cost-effective analytical method for the determination of zerumbone using UV-Vis spectrophotometry. Method validation was conducted according to ICH Q2(R2) guidelines, including tests for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision. Zerumbone exhibited a maximum absorption wavelength (λmax) of 212 nm when dissolved in dimethyl sulfoxide (DMSO). The method demonstrated excellent linearity with a determination coefficient (R2) of 0.9991 across a concentration range of 10-50 μg/mL. Accuracy, evaluated via recovery studies, ranged from 91,00% to 110,45%. Precision testing results in a % RSD of 0.58%. The calculated LOD and LOQ were 1.55 μg/mL and 4.70 μg/mL, respectively. This validated method is simple, rapid, and economical, making it a promising alternative for zerumbone analysis in quality control laboratories.
&amp;nbsp;
Keywords: Zerumbone, Method Development, UV-Vis Spectrophotometry, Validation, ICH Guidelines.
&amp;nbsp;</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2025-11-24</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/15690</dc:identifier>
	<dc:identifier>10.20884/1.jm.2025.20.3.15690</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 20 No 3 (2025); 505-510</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/15690/7526</dc:relation>
</oai_dc:dc>