Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Electrochemistry Response of Platinum Powder Composite as Electrode for Sensor Capsaicin

Molekul: Jurnal Ilmiah Kimia · Vol. 20 No. 2 (2025) · hlm. 373–381

DOI
10.20884/1.jm.2025.20.2.15943
ISSN
2503-0310, 1907-9761
Terbit
2025-07-24
Penerbit
Universitas Jenderal Soedirman
Bahasa
eng

Abstrak

ABSTRACT. So far, the concentration of capsaicin in food has been determined using the tongue. Several analytical methods were developed to determine the concentration of capsaicin, but they have many drawbacks such as being expensive, long analysis time, requiring hazardous chemicals, and being difficult to operate. This research aims to prepare a material that has high stability and excellent electrocatalytic activity to determine capsaicin concentration. The research was conducted by preparing powdered platinum electrodes mixed with polyvinyl chloride (PVC). The mixture of the two materials is added with tetrahydrofuran (THF), dried, and pressed so that it becomes a solid electrode which is a platinum powder composite (PPC). These electrodes are used as working electrodes for the analysis of capsaicin in food sauce. The results showed that the NaOH electrolyte was the best electrolyte for capsaicin analysis using platinum powder composite electrodes. The PPC electrode showed good test method validation results, namely recovery of 108.69%, LOD, and LOQ of 5.9 x 10-1 mM and 19.9 x 10-1 mM, respectively. The capsaicin concentration in the food sauce was 0.029 M in a 0.5 g sample. Keywords: Capsaicin, composite, cyclic voltammetry, platinum powder, sensor

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Islamic University of Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jos.unsoed.ac.id/index.php/jm/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US"> Electrochemistry Response of Platinum Powder Composite as Electrode for Sensor Capsaicin</dc:title>
	<dc:creator>Riyanto, Riyanto</dc:creator>
	<dc:creator>Fadilla, Nadiya Irmasakti</dc:creator>
	<dc:creator>Ningrum, Indah Rohmah Wahyu</dc:creator>
	<dc:description xml:lang="en-US">ABSTRACT. So far, the concentration of capsaicin in food has been determined using the tongue. Several analytical methods were developed to determine the concentration of capsaicin, but they have many drawbacks such as being expensive, long analysis time, requiring hazardous chemicals, and being difficult to operate. This research aims to prepare a material that has high stability and excellent electrocatalytic activity to determine capsaicin concentration. The research was conducted by preparing powdered platinum electrodes mixed with polyvinyl chloride (PVC). The mixture of the two materials is added with tetrahydrofuran (THF), dried, and pressed so that it becomes a solid electrode which is a platinum powder composite (PPC). These electrodes are used as working electrodes for the analysis of capsaicin in food sauce. The results showed that the NaOH electrolyte was the best electrolyte for capsaicin analysis using platinum powder composite electrodes. The PPC electrode showed good test method validation results, namely recovery of 108.69%, LOD, and LOQ of 5.9 x 10-1 mM and 19.9 x 10-1 mM, respectively. The capsaicin concentration in the food sauce was 0.029 M in a 0.5 g sample.
&amp;nbsp;
Keywords: Capsaicin, composite, cyclic voltammetry, platinum powder, sensor</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Jenderal Soedirman</dc:publisher>
	<dc:date>2025-07-24</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jos.unsoed.ac.id/index.php/jm/article/view/15943</dc:identifier>
	<dc:identifier>10.20884/1.jm.2025.20.2.15943</dc:identifier>
	<dc:source xml:lang="en-US">Molekul; Vol 20 No 2 (2025); 373-381</dc:source>
	<dc:source>2503-0310</dc:source>
	<dc:source>1907-9761</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jos.unsoed.ac.id/index.php/jm/article/view/15943/7175</dc:relation>
</oai_dc:dc>