Jurnal
SINTA 1
FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK
Public Health of Indonesia · Vol. 6 No. 2 (2020) · hlm. 47–56
ISSN 2477-1570, 2528-1542
Terbit 2020-05-18
Penerbit YCAB Publisher
Bahasa eng
Abstrak
Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok.Study Design: Cross-sectional studyMethods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples were collected to test coliform bacteria contamination.Results: Coliform bacteria were detected in 28.5% of samples. Links were found between coliform contamination and filter cleaning practices in 57 maintenance persons' responses. Filters cleaned < 3 times per year were at higher risk of coliform contamination (OR 14.49, 95% CI 1.76-125.00). A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83).Conclusion: A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). These results emphasized the importance of effective vending-machine maintenance and monitoring drinking-water quality.
Jaringan kolaborasi para penulis
5 penulis ·
6 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://stikbar.org/ycabpublisher/index.php/PHI/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK</dc:title>
<dc:creator>Kita, Akemi</dc:creator>
<dc:creator>Sihabut, Tanasri</dc:creator>
<dc:creator>Tantrakarnapa, Kraichat</dc:creator>
<dc:subject xml:lang="en-US">drinking water</dc:subject>
<dc:subject xml:lang="en-US">vending machine</dc:subject>
<dc:subject xml:lang="en-US">Bangkok</dc:subject>
<dc:subject xml:lang="en-US">maintenance</dc:subject>
<dc:description xml:lang="en-US">Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok.Study Design: Cross-sectional studyMethods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples were collected to test coliform bacteria contamination.Results: Coliform bacteria were detected in 28.5% of samples. Links were found between coliform contamination and filter cleaning practices in 57 maintenance persons' responses. Filters cleaned &lt; 3 times per year were at higher risk of coliform contamination (OR 14.49, 95% CI 1.76-125.00). A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83).Conclusion: A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). These results emphasized the importance of effective vending-machine maintenance and monitoring drinking-water quality.</dc:description>
<dc:publisher xml:lang="en-US">YCAB Publisher</dc:publisher>
<dc:date>2020-05-18</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://stikbar.org/ycabpublisher/index.php/PHI/article/view/338</dc:identifier>
<dc:identifier>10.36685/phi.v6i2.338</dc:identifier>
<dc:source xml:lang="en-US">Public Health of Indonesia; Vol. 6 No. 2 (2020): April - June; 47-56</dc:source>
<dc:source>2477-1570</dc:source>
<dc:source>2528-1542</dc:source>
<dc:source>10.36685/phi.v6i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://stikbar.org/ycabpublisher/index.php/PHI/article/view/338/pdf</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2020 Akemi Kita, Tanasri Sihabut, Kraichat Tantrakarnapa</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Kita, A., Sihabut, T., & Tantrakarnapa, K. (2020). FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK. Public Health of Indonesia, 6(2), 47–56. https://doi.org/10.36685/phi.v6i2.338
Salin
IEEE
A. Kita, T. Sihabut, and K. Tantrakarnapa, “FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK,” Public Health of Indonesia, vol. 6, no. 2, pp. 47–56, 2020, doi: 10.36685/phi.v6i2.338.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.