FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK

Public Health of Indonesia · Vol. 6 No. 2 (2020) · hlm. 47–56

DOI
10.36685/phi.v6i2.338
ISSN
2477-1570, 2528-1542
Terbit
2020-05-18
Penerbit
YCAB Publisher
Bahasa
eng

Abstrak

Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok.Study Design: Cross-sectional studyMethods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples were collected to test coliform bacteria contamination.Results: Coliform bacteria were detected in 28.5% of samples. Links were found between coliform contamination and filter cleaning practices in 57 maintenance persons' responses. Filters cleaned < 3 times per year were at higher risk of coliform contamination (OR 14.49, 95% CI 1.76-125.00). A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83).Conclusion: A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). These results emphasized the importance of effective vending-machine maintenance and monitoring drinking-water quality.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mahidol University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wissanupong KliengchuayMahidol University1
Sawake ChommingMahidol University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://stikbar.org/ycabpublisher/index.php/PHI/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK</dc:title>
	<dc:creator>Kita, Akemi</dc:creator>
	<dc:creator>Sihabut, Tanasri</dc:creator>
	<dc:creator>Tantrakarnapa, Kraichat</dc:creator>
	<dc:subject xml:lang="en-US">drinking water</dc:subject>
	<dc:subject xml:lang="en-US">vending machine</dc:subject>
	<dc:subject xml:lang="en-US">Bangkok</dc:subject>
	<dc:subject xml:lang="en-US">maintenance</dc:subject>
	<dc:description xml:lang="en-US">Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok.Study Design: Cross-sectional studyMethods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples were collected to test coliform bacteria contamination.Results: Coliform bacteria were detected in 28.5% of samples. Links were found between coliform contamination and filter cleaning practices in 57 maintenance persons' responses. Filters cleaned &amp;lt; 3 times per year were at higher risk of coliform contamination (OR 14.49, 95% CI 1.76-125.00). A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83).Conclusion: A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). These results emphasized the importance of effective vending-machine maintenance and monitoring drinking-water quality.</dc:description>
	<dc:publisher xml:lang="en-US">YCAB Publisher</dc:publisher>
	<dc:date>2020-05-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://stikbar.org/ycabpublisher/index.php/PHI/article/view/338</dc:identifier>
	<dc:identifier>10.36685/phi.v6i2.338</dc:identifier>
	<dc:source xml:lang="en-US">Public Health of Indonesia; Vol. 6 No. 2 (2020): April - June; 47-56</dc:source>
	<dc:source>2477-1570</dc:source>
	<dc:source>2528-1542</dc:source>
	<dc:source>10.36685/phi.v6i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://stikbar.org/ycabpublisher/index.php/PHI/article/view/338/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Akemi Kita, Tanasri Sihabut, Kraichat Tantrakarnapa</dc:rights>
</oai_dc:dc>