STUDY OF CALCIUM SULFATE SCALING INDEX TENDENCY CALCULATIONS AT DIFFERENT TEMPERATURE CONDITIONS IN INJECTION WATER SAMPLES FROM OILFIELDS

Scientific Contributions Oil and Gas · Vol. 30 No. 3 (2022) · hlm. 13–22

DOI
10.29017/SCOG.30.3.975
ISSN
2541-0520, 2089-3361
Terbit
2022-03-29
Penerbit
Testing Center for Oil and Gas LEMIGAS
Bahasa
eng
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

Calcium sulfate scale is a type of scale found in petroleum industry and shows seriousproblem, because it can plug pore media and cause a decrease in production rate.Actual calcium sulfate (CaSO4) concentrations of S1, S2, S3 and S4 injection watersamples were in the range of 0.0208 to 0.4583 meq/l. While, the values of solubility ofS1, S2, S3 and S4 water samples at 77,145 and 1770F are in a range of 23.20 to 27.43meq/l. Based on the results of calcium sulfate scaling tendency calculations showed thatthe values of solubility of S1, S2, S3 and S4 water samples at various temperature conditions(77,140 and 1750F) are higher than actual CaSO4 concentrations for the samewater samples. No occurrence of CaSO4 scale was found in all analyzed injection watersamples at different temperature conditions (77,140 and 1750F).

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 8 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Halu Oleo
  • State University of Semarang
  • Universitas Islam Negeri Ar-Raniry
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nuraini NurainiUniversitas Halu Oleo4
Panca WahyudiAfiliasi tidak diketahui2
Supriyatno SupriyatnoState University of Semarang1
Nuraini NurainiUniversitas Islam Negeri Ar-Raniry1
Hadi PoernomoAfiliasi tidak diketahui1
Hadi PurnomoAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.lemigas.esdm.go.id/index.php/SCOG/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 10 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">STUDY OF CALCIUM SULFATE SCALING INDEX TENDENCY CALCULATIONS AT DIFFERENT TEMPERATURE CONDITIONS IN INJECTION WATER SAMPLES FROM OILFIELDS</dc:title>
	<dc:creator xml:lang="en">Makmur, Tjuwati</dc:creator>
	<dc:subject xml:lang="en">calcium sulfate scale</dc:subject>
	<dc:subject xml:lang="en">scaling index tendency calculation</dc:subject>
	<dc:subject xml:lang="en">solubility of injection water sample and actual CaSO4 concentration</dc:subject>
	<dc:description xml:lang="en">Calcium sulfate scale is a type of scale found in petroleum industry and shows seriousproblem, because it can plug pore media and cause a decrease in production rate.Actual calcium sulfate (CaSO4) concentrations of S1, S2, S3 and S4 injection watersamples were in the range of 0.0208 to 0.4583 meq/l. While, the values of solubility ofS1, S2, S3 and S4 water samples at 77,145 and 1770F are in a range of 23.20 to 27.43meq/l. Based on the results of calcium sulfate scaling tendency calculations showed thatthe values of solubility of S1, S2, S3 and S4 water samples at various temperature conditions(77,140 and 1750F) are higher than actual CaSO4 concentrations for the samewater samples. No occurrence of CaSO4 scale was found in all analyzed injection watersamples at different temperature conditions (77,140 and 1750F).</dc:description>
	<dc:publisher xml:lang="en">Testing Center for Oil and Gas LEMIGAS</dc:publisher>
	<dc:date>2022-03-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/975</dc:identifier>
	<dc:identifier>10.29017/SCOG.30.3.975</dc:identifier>
	<dc:source xml:lang="en">Scientific Contributions Oil and Gas; Vol. 30 No. 3 (2007); 13-22</dc:source>
	<dc:source xml:lang="id">Scientific Contributions Oil and Gas; Vol 30 No 3 (2007); 13-22</dc:source>
	<dc:source>2541-0520</dc:source>
	<dc:source>2089-3361</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/975/767</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 1970 SCIENTIFIC CONTRIBUTIONS OIL AND GAS (SCOG)</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>