Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design of a Swab Cup Running Tool to Reduce Fluid Bypass during Liquid Swabbing Operations in Dual Size Tubing Completion Oil and Gas Wells

Scientific Contributions Oil and Gas · Vol. 49 No. 3 (2026) · hlm. 279–298

DOI
10.29017/scog.v49i3.2155
ISSN
2541-0520, 2089-3361
Terbit
2026-09-29
Penerbit
Testing Center for Oil and Gas LEMIGAS
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Swabbing is a liquid unloading method used in the oil and gas industry to reduce hydrostatic pressure caused by fluid accumulation in the wellbore. In wells with dual-size tubing completions (4.5-inch and 3.5-inch), tubing diameter transitions can reduce Swab Cup sealing performance, causing fluid bypass and lowering lifting efficiency. This study develops a modified Swab Cup Carrier and swab mandrel to support continuous fluid lifting in dual-size tubing completions. An engineering design research approach was applied, including field problem identification, conceptual design, Computer-Aided Design (CAD), Finite Element Analysis (FEA), prototype development, tubing simulation, and functional evaluation. The proposed design incorporates a cam-guided release-and-carry mechanism that enables the Swab Cup Carrier to release at the tubing X-over during Run In Hole and reconnect during Pull Out of Hole. FEA of AISI 4130 alloy steel showed a maximum von Mises stress of 278.6 MPa, below the material yield strength of 460 MPa, indicating adequate structural safety. Prototype testing using a PVC tubing simulation verified the proposed mechanism. The design has the potential to minimise fluid bypass, maintain lifting continuity, and improve swabbing effectiveness in dual-size tubing completions. Further laboratory and field validation is required to confirm its operational performance.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 59 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Pertamina (Indonesia)
  • Tanri Abeng University
  • Islamic University of Riau
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dedy IrawanBandung Institute of Technology2
Fahrizal MaulanaBandung Institute of Technology2
Tjok Gede SatryanggaAfiliasi tidak diketahui2
Amritzar AimarAfiliasi tidak diketahui2
Seno KushidayatAfiliasi tidak diketahui2
Kamal HamzahAfiliasi tidak diketahui1
Mohammed Sheikh Salem Al-AttasAfiliasi tidak diketahui1
Jalest SeptianoBandung Institute of Technology1
Silvya Dewi RahmawatiBandung Institute of Technology1
Reza WardhanaBandung Institute of Technology1
Mochammad Wahdanadi HaidarPertamina (Indonesia)1
Farrah MaurenzaBandung Institute of Technology1
Iswara Lumban TungkupBandung Institute of Technology1
Joe Felix TurnipBandung Institute of Technology1
Sri Dwi MustaqimBandung Institute of Technology1
Zuher SyihabBandung Institute of Technology1
Tutuka AriadjiBandung Institute of Technology1
Rian Cahya RohmanaTanri Abeng University1
Dedy IrawanBandung Institute of Technology1
Jeffier WinartaAfiliasi tidak diketahui1
Fajril AmbiaIslamic University of Riau1
Jeffier WinartaBandung Institute of Technology1
Dedy IrawanBandung Institute of Technology1
Roihan NirwanaBandung Institute of Technology1
Syarif Fikri KamalAfiliasi tidak diketahui1
Welly Ahmad RamadanAfiliasi tidak diketahui1
Adam MuhammadBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.lemigas.esdm.go.id/index.php/SCOG/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 10 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Design of a Swab Cup Running Tool to Reduce Fluid Bypass during Liquid Swabbing Operations in Dual Size Tubing Completion Oil and Gas Wells</dc:title>
	<dc:creator xml:lang="en">Karnando</dc:creator>
	<dc:creator xml:lang="en">Dedy Irawan</dc:creator>
	<dc:creator xml:lang="en">Amega Yasutra</dc:creator>
	<dc:subject xml:lang="en">swabbing</dc:subject>
	<dc:subject xml:lang="en">swab cup carrier</dc:subject>
	<dc:subject xml:lang="en">dual-size tubing completion</dc:subject>
	<dc:description xml:lang="en">Swabbing is a liquid unloading method used in the oil and gas industry to reduce hydrostatic pressure caused by fluid accumulation in the wellbore. In wells with dual-size tubing completions (4.5-inch and 3.5-inch), tubing diameter transitions can reduce Swab Cup sealing performance, causing fluid bypass and lowering lifting efficiency. This study develops a modified Swab Cup Carrier and swab mandrel to support continuous fluid lifting in dual-size tubing completions. An engineering design research approach was applied, including field problem identification, conceptual design, Computer-Aided Design (CAD), Finite Element Analysis (FEA), prototype development, tubing simulation, and functional evaluation. The proposed design incorporates a cam-guided release-and-carry mechanism that enables the Swab Cup Carrier to release at the tubing X-over during Run In Hole and reconnect during Pull Out of Hole. FEA of AISI 4130 alloy steel showed a maximum von Mises stress of 278.6 MPa, below the material yield strength of 460 MPa, indicating adequate structural safety. Prototype testing using a PVC tubing simulation verified the proposed mechanism. The design has the potential to minimise fluid bypass, maintain lifting continuity, and improve swabbing effectiveness in dual-size tubing completions. Further laboratory and field validation is required to confirm its operational performance.</dc:description>
	<dc:publisher xml:lang="en">Testing Center for Oil and Gas LEMIGAS</dc:publisher>
	<dc:date>2026-09-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/2155</dc:identifier>
	<dc:identifier>10.29017/scog.v49i3.2155</dc:identifier>
	<dc:source xml:lang="en">Scientific Contributions Oil and Gas; Vol. 49 No. 3 (2026); 279-298</dc:source>
	<dc:source xml:lang="id">Scientific Contributions Oil and Gas; Vol 49 No 3 (2026); 279-298</dc:source>
	<dc:source>2541-0520</dc:source>
	<dc:source>2089-3361</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.lemigas.esdm.go.id/index.php/SCOG/article/view/2155/1760</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Copyright by Authors. Published by LEMIGAS</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>