Melola Discovery

← Melola Discovery

Jurnal SINTA 1

MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS

Sinergi · Vol. 22 No. 3 (2018) · hlm. 211–218

DOI
10.22441/sinergi.2018.3.010
ISSN
2460-1217, 1410-2331
Terbit
2018-10-29
Penerbit
Universitas Mercu Buana
Bahasa
eng

Abstrak

Electricity is one of the most important human needs. In the presence of electricity it can facilitate human work. But it should be noted that too large and uncontrolled electricity use will be wasteful and get high costs. The problem is that electricity is not monitored accurately, easily and efficiently. This study aims to design an electric current monitoring device with an IoT system. IoT is a concept with the ability to transfer data by network, no need humans to humans or humans to PCs. In this concept, the SCT 013-000 electric current sensor is connected to the load, it will be show electric current value in the LCD, if the electric current which is determined exceeds the capacity, Wemos D1 including Wifi ESP 8266 will be sending a notification to the telegram. The system has been implemented with ironing load for 3.29%, the dispenser load is 0.20% and Magicom's get load for 1.07%. The delay time also has been implemented in the relay for 1.50 second when relay is on and 0.78 second when relay is off. When the notification send to the telegram also have a delay for 6.2 second. So, monitoring of electrical system using internet of things with smart current electric sensors has been done.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 30 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mercu Buana University
  • Shanghai University
  • First City University College
  • Universitas Muhammadiyah Prof Dr Hamka
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Heru SuwoyoMercu Buana University4
Fadli SiraitMercu Buana University2
Yingzhong TianShanghai University2
Julpri AndikaMercu Buana University1
Ulil AlbabMercu Buana University1
Yuliza YulizaMercu Buana University1
Fina SupeginaMercu Buana University1
Rohilah SahakFirst City University College1
Kresna Jery KusnantoMercu Buana University1
Prastika IndriyantiMercu Buana University1
Arafat FebriandirzaUniversitas Muhammadiyah Prof Dr Hamka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS</dc:title>
	<dc:creator>Ibnu Hajar, Muhammad Hafizd</dc:creator>
	<dc:creator>Dani, Akhmad Wahyu</dc:creator>
	<dc:creator>Miharno, Satriyo</dc:creator>
	<dc:subject xml:lang="en-US">Monitoring System</dc:subject>
	<dc:subject xml:lang="en-US">Internet of Things</dc:subject>
	<dc:subject xml:lang="en-US">Wemos Module</dc:subject>
	<dc:subject xml:lang="en-US">Current Electric SCT-013 000</dc:subject>
	<dc:description xml:lang="en-US">Electricity is one of the most important human needs. In the presence of electricity it can facilitate human work. But it should be noted that too large and uncontrolled electricity use will be wasteful and get high costs. The problem is that electricity is not monitored accurately, easily and efficiently. This study aims to design an electric current monitoring device with an IoT system. IoT is a concept with the ability to transfer data by network, no need humans to humans or humans to PCs. In this concept, the SCT 013-000 electric current sensor is connected to the load, it will be show electric current value in the LCD, if the electric current which is determined exceeds the capacity, Wemos D1 including Wifi ESP 8266 will be sending a notification to the telegram. The system has been implemented with ironing load for 3.29%, the dispenser load is 0.20% and Magicom's get load for 1.07%. The delay time also has been implemented in the relay for 1.50 second when relay is on and 0.78 second when relay is off. When the notification send to the telegram also have a delay for 6.2 second. So, monitoring of electrical system using internet of things with smart current electric sensors has been done.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2018-10-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/2921</dc:identifier>
	<dc:identifier>10.22441/sinergi.2018.3.010</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 22 No. 3 (2018); 211-218</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/2921/2123</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 SINERGI</dc:rights>
</oai_dc:dc>