Jurnal
SINTA 1
MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS
Sinergi · Vol. 22 No. 3 (2018) · hlm. 211–218
ISSN 2460-1217, 1410-2331
Terbit 2018-10-29
Penerbit Universitas Mercu Buana
Bahasa eng
Abstrak
Electricity is one of the most important human needs. In the presence of electricity it can facilitate human work. But it should be noted that too large and uncontrolled electricity use will be wasteful and get high costs. The problem is that electricity is not monitored accurately, easily and efficiently. This study aims to design an electric current monitoring device with an IoT system. IoT is a concept with the ability to transfer data by network, no need humans to humans or humans to PCs. In this concept, the SCT 013-000 electric current sensor is connected to the load, it will be show electric current value in the LCD, if the electric current which is determined exceeds the capacity, Wemos D1 including Wifi ESP 8266 will be sending a notification to the telegram. The system has been implemented with ironing load for 3.29%, the dispenser load is 0.20% and Magicom's get load for 1.07%. The delay time also has been implemented in the relay for 1.50 second when relay is on and 0.78 second when relay is off. When the notification send to the telegram also have a delay for 6.2 second. So, monitoring of electrical system using internet of things with smart current electric sensors has been done.
Jaringan kolaborasi para penulis
14 penulis ·
30 tautan kepenulisan bersama
· 10 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mercu Buana University Shanghai University First City University College Universitas Muhammadiyah Prof Dr Hamka
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS</dc:title>
<dc:creator>Ibnu Hajar, Muhammad Hafizd</dc:creator>
<dc:creator>Dani, Akhmad Wahyu</dc:creator>
<dc:creator>Miharno, Satriyo</dc:creator>
<dc:subject xml:lang="en-US">Monitoring System</dc:subject>
<dc:subject xml:lang="en-US">Internet of Things</dc:subject>
<dc:subject xml:lang="en-US">Wemos Module</dc:subject>
<dc:subject xml:lang="en-US">Current Electric SCT-013 000</dc:subject>
<dc:description xml:lang="en-US">Electricity is one of the most important human needs. In the presence of electricity it can facilitate human work. But it should be noted that too large and uncontrolled electricity use will be wasteful and get high costs. The problem is that electricity is not monitored accurately, easily and efficiently. This study aims to design an electric current monitoring device with an IoT system. IoT is a concept with the ability to transfer data by network, no need humans to humans or humans to PCs. In this concept, the SCT 013-000 electric current sensor is connected to the load, it will be show electric current value in the LCD, if the electric current which is determined exceeds the capacity, Wemos D1 including Wifi ESP 8266 will be sending a notification to the telegram. The system has been implemented with ironing load for 3.29%, the dispenser load is 0.20% and Magicom's get load for 1.07%. The delay time also has been implemented in the relay for 1.50 second when relay is on and 0.78 second when relay is off. When the notification send to the telegram also have a delay for 6.2 second. So, monitoring of electrical system using internet of things with smart current electric sensors has been done.</dc:description>
<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
<dc:date>2018-10-29</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/2921</dc:identifier>
<dc:identifier>10.22441/sinergi.2018.3.010</dc:identifier>
<dc:source xml:lang="en-US">SINERGI; Vol. 22 No. 3 (2018); 211-218</dc:source>
<dc:source>2460-1217</dc:source>
<dc:source>1410-2331</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/2921/2123</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2018 SINERGI</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Ibnu Hajar, M. H., Dani, A. W., & Miharno, S. (2018). MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS. Sinergi, 22(3), 211–218. https://doi.org/10.22441/sinergi.2018.3.010
Salin
IEEE
M. H. Ibnu Hajar, A. W. Dani, and S. Miharno, “MONITORING OF ELECTRICAL SYSTEM USING INTERNET OF THINGS WITH SMART CURRENT ELECTRIC SENSORS,” Sinergi, vol. 22, no. 3, pp. 211–218, 2018, doi: 10.22441/sinergi.2018.3.010.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.