Melola Discovery

← Melola Discovery

Jurnal SINTA 1

CONDENSOR DESIGN ANALYSIS WITH KAYS AND LONDON SURFACE DIMENSIONS

Sinergi · Vol. 24 No. 2 (2020) · hlm. 81–86

DOI
10.22441/sinergi.2020.2.001
ISSN
2460-1217, 1410-2331
Terbit
2020-04-17
Penerbit
Universitas Mercu Buana
Bahasa
eng

Abstrak

The use of condensers in air conditioning units is more common in large-capacity units than in ones with a smaller capacity. Air conditioning provides comfort and freshness to an air-conditioned room. It should be noted that each room has a different heat load, which affects the specifications of the condenser used. The accuracy with which appropriate condenser specifications are determined affects the performance of the air conditioner. Thus, considering how important condenser needs are, it is necessary to design condensers with optimal performance, which adhere to proven standards. To achieve this, the design of a condenser should be based on the results of the smallest condenser dimensions of three types of surfaces, as they are intended for a limited place. This condenser design uses the standard dimensions of the Kays and London charts. Data is collected by measuring the results of temperature and enthalpy of a refrigerant at desuperheating and condensation, inlet air temperature, outlet air temperature, refrigerant mass flow rate, and air mass flow rate. The results of the compact condenser design are based on existing data, which is obtained from the smallest design results. The result uses the type of Surface CF-8.72(c) with a heat transfer area of 0.259 m2, a total tube length of 9.5 m, crossing tube length 0.594 m and a pressure drop of 3778 Pascal (Pa) on the side of a tube. This design fulfills the stipulated requirements, as the pressure drop is less than the specified maximum limit in most units.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 135 tautan kepenulisan bersama · 61 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mercu Buana University
  • Beijing Institute of Technology
  • Nanjing University of Science and Technology
  • Ungku Omar Polytechnic
  • National University of Malaysia
  • Kyushu University
  • National Taiwan University of Science and Technology
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dafit FeriyantoMercu Buana University6
Fajar AnggaraMercu Buana University5
Rikko Putra YouliaMercu Buana University5
Aberham Genetu FelekeBeijing Institute of Technology4
Alief Avicenna LuthfieMercu Buana University4
Wiwit SuprihatiningsihMercu Buana University3
Hui XiongBeijing Institute of Technology3
Muhamad FitriMercu Buana University2
Hadi PranotoMercu Buana University2
Nurato NuratoMercu Buana University2
Supaat ZakariaUngku Omar Polytechnic2
Nur IndahNational University of Malaysia1
Rachmat MuwardiMercu Buana University1
Imam HidayatMercu Buana University1
Muhammad ImranBeijing Institute of Technology1
Rahmat WahyudiMercu Buana University1
Solli Dwi MurtyasKyushu University1
Hanif GhufronMercu Buana University1
Andi Firdaus SudarmaMercu Buana University1
Yosua Heru IrawanNational Taiwan University of Science and Technology1
Hifdzul Luthfan HabibullahMercu Buana University1
Diah UtamiMercu Buana University1
Yang XiaweiNorthwestern Polytechnical University1
Yudha Aji PramonoMercu Buana University1
Fathoni Putra WijayaAfiliasi tidak diketahui1
Dong WangBeijing Institute of Technology1
Muhammad ImranBeijing Institute of Technology1
Himawan S. WibisonoMercu Buana University1
Agung Wahyudi BiantoroMercu Buana University1
Tri Wahyu AdinartoMercu Buana University1
Fatkur RachmanuPoliteknik Enjinering Indorama1
Imam HidayatMercu Buana University1
S.S. AbdulmalikAfiliasi tidak diketahui1
Irfan Evi NugrohoMercu Buana University1
Alina AlinaIndonesia Open University1
Alfian NoviyantoMercu Buana University1
Hadi PranotoMercu Buana University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">CONDENSOR DESIGN ANALYSIS WITH KAYS AND LONDON SURFACE DIMENSIONS</dc:title>
	<dc:creator>Romahadi, Dedik</dc:creator>
	<dc:creator>Ruhyat, Nanang</dc:creator>
	<dc:creator>Desti Dorion, L. B.</dc:creator>
	<dc:subject xml:lang="en-US">Condenser</dc:subject>
	<dc:subject xml:lang="en-US">Air conditioning</dc:subject>
	<dc:subject xml:lang="en-US">Heat exchanger</dc:subject>
	<dc:description xml:lang="en-US">The use of condensers in air conditioning units is more common in large-capacity units than in ones with a smaller capacity. Air conditioning provides comfort and freshness to an air-conditioned room. It should be noted that each room has a different heat load, which affects the specifications of the condenser used. The accuracy with which appropriate condenser specifications are determined affects the performance of the air conditioner. Thus, considering how important condenser needs are, it is necessary to design condensers with optimal performance, which adhere to proven standards. To achieve this, the design of a condenser should be based on the results of the smallest condenser dimensions of three types of surfaces, as they are intended for a limited place. This condenser design uses the standard dimensions of the Kays and London charts. Data is collected by measuring the results of temperature and enthalpy of a refrigerant at desuperheating and condensation, inlet air temperature, outlet air temperature, refrigerant mass flow rate, and air mass flow rate. The results of the compact condenser design are based on existing data, which is obtained from the smallest design results. The result uses the type of Surface CF-8.72(c) with a heat transfer area of 0.259 m2, a total tube length of 9.5 m, crossing tube length 0.594 m and a pressure drop of 3778 Pascal (Pa) on the side of a tube. This design fulfills the stipulated requirements, as the pressure drop is less than the specified maximum limit in most units. </dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2020-04-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>application/vnd.openxmlformats-officedocument.wordprocessingml.document</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/5552</dc:identifier>
	<dc:identifier>10.22441/sinergi.2020.2.001</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 24 No. 2 (2020); 81-86</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/5552/3342</dc:relation>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/5552/10750</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 SINERGI</dc:rights>
</oai_dc:dc>