Jurnal
SINTA 1
FIBERGLASS CIRCULAR TURBULATOR IN COUNTER FLOW DOUBLE PIPE HEAT EXCHANGER: A STUDY OF HEAT TRANSFER RATE AND PRESSURE DROP
Sinergi · Vol. 25 No. 1 (2020) · hlm. 51–58
ISSN 2460-1217, 1410-2331
Terbit 2020-11-08
Penerbit Universitas Mercu Buana
Bahasa eng
Abstrak
This preliminary investigation studied the effect of circular turbulator vortex generator on heat transfer rate and pressure drop in a circular channel countercurrent double pipe heat exchanger with water working fluid. Increasing the number of circular turbulator yielded increasing heat transfer rate and pressure drop. The problem generated when increased pressure drop occurred in relation to more energy consumption of the water pumping system. Therefore, optimization in circular turbulator number is necessary to minimize the pressure drop about distance length between circular turbulator, tube diameter and thickness, type of material and crystal lattice, as well as the geometrical shape of fluid passage (circular or square). This study applied PVC outer tube and copper alloy inner tube, as well as fiberglass circular turbulator. The optimum results showed that seven parts of circular turbulator increasing heat transfer rate by 30% and pressure drop by 80% compared to that passage in the absence of circular turbulator at cool water debit of 7 L/min.
Jaringan kolaborasi para penulis
18 penulis ·
45 tautan kepenulisan bersama
· 33 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mercu Buana University Universitas Trisakti Islamic University of Riau Institut Teknologi Sepuluh Nopember Institut Teknologi Padang Universitas Sumatera Utara National University of Malaysia Organisasi lain
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 10 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">FIBERGLASS CIRCULAR TURBULATOR IN COUNTER FLOW DOUBLE PIPE HEAT EXCHANGER: A STUDY OF HEAT TRANSFER RATE AND PRESSURE DROP</dc:title>
<dc:creator>Sudiono, Sudiono</dc:creator>
<dc:creator>Sundari, Rita</dc:creator>
<dc:creator>Anggraini, Rini</dc:creator>
<dc:subject xml:lang="en-US">Circular Turbulator</dc:subject>
<dc:subject xml:lang="en-US">Heat Exchanger</dc:subject>
<dc:subject xml:lang="en-US">Heat Transfer Rate</dc:subject>
<dc:subject xml:lang="en-US">Pressure Drop</dc:subject>
<dc:description xml:lang="en-US">This preliminary investigation studied the effect of circular turbulator vortex generator on heat transfer rate and pressure drop in a circular channel countercurrent double pipe heat exchanger with water working fluid. Increasing the number of circular turbulator yielded increasing heat transfer rate and pressure drop. The problem generated when increased pressure drop occurred in relation to more energy consumption of the water pumping system. Therefore, optimization in circular turbulator number is necessary to minimize the pressure drop about distance length between circular turbulator, tube diameter and thickness, type of material and crystal lattice, as well as the geometrical shape of fluid passage (circular or square). This study applied PVC outer tube and copper alloy inner tube, as well as fiberglass circular turbulator. The optimum results showed that seven parts of circular turbulator increasing heat transfer rate by 30% and pressure drop by 80% compared to that passage in the absence of circular turbulator at cool water debit of 7 L/min. </dc:description>
<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
<dc:date>2020-11-08</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8179</dc:identifier>
<dc:identifier>10.22441/sinergi.2021.1.007</dc:identifier>
<dc:source xml:lang="en-US">SINERGI; Vol. 25 No. 1 (2021); 51-58</dc:source>
<dc:source>2460-1217</dc:source>
<dc:source>1410-2331</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8179/3967</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 SINERGI</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat DOI
2 sitasi
Crossref
Belum diperiksa
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Sudiono, S., Sundari, R., & Anggraini, R. (2020). FIBERGLASS CIRCULAR TURBULATOR IN COUNTER FLOW DOUBLE PIPE HEAT EXCHANGER: A STUDY OF HEAT TRANSFER RATE AND PRESSURE DROP. Sinergi, 25(1), 51–58. https://doi.org/10.22441/sinergi.2021.1.007
Salin
IEEE
S. Sudiono, R. Sundari, and R. Anggraini, “FIBERGLASS CIRCULAR TURBULATOR IN COUNTER FLOW DOUBLE PIPE HEAT EXCHANGER: A STUDY OF HEAT TRANSFER RATE AND PRESSURE DROP,” Sinergi, vol. 25, no. 1, pp. 51–58, 2020, doi: 10.22441/sinergi.2021.1.007.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.