The effect of variation of shear walls placement on the response of building structure using the Direct Displacement-Based Design method

Sinergi · Vol. 26 No. 2 (2022) · hlm. 201–212

DOI
10.22441/sinergi.2022.2.009
ISSN
2460-1217, 1410-2331
Terbit
2022-06-15
Penerbit
Universitas Mercu Buana
Bahasa
eng

Abstrak

Shear walls' placement in specific positions could develop different structural responses to the building and affect the structure's strength to the received lateral loads. This research aims to find the variations in the shear walls' placement on the structure's response under the Direct Displacement Based Design (DDBD) method. The object of this research is the model of a 10-story reinforced concrete building located in Yogyakarta, Indonesia. Modelling of building structures is carried out in this study with four variations of shear wall placement. First, the walls are located at every building's corner. The shear wall is then positioned in the core of the building, where the apertures have shrunk. Then, the shear wall is located on the edge of the building. Last, the shear wall is located on the edge of the building. ANOVA method is used to analyze the significant difference, i.e., variations in the walls' placement. This research indicates the significant differences in the x-direction shear force and the y-direction moment The shear walls are suggested to be placed according to the building's condition and the earthquake ground site's class to produce an optimal structure to resist earthquake loads.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 22 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Ketut SucitaJakarta State Polytechnic5
Jasun Widiana PutraJakarta State Polytechnic2
Oky Bima PutraJakarta State Polytechnic2
Ilham Dwiputra RamadhanJakarta State Polytechnic2
Tree Irma DindaJakarta State Polytechnic2
Alvin DunaufalJakarta State Polytechnic1
Hanan YurizkaJakarta State Polytechnic1
Nadhila Ramadhani A.P.Jakarta State Polytechnic1
Annisaa Dina PuspitaJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The effect of variation of shear walls placement on the response of building structure using the Direct Displacement-Based Design method</dc:title>
	<dc:creator>Aji, Hanif Satria</dc:creator>
	<dc:creator>Rosyidah, Anis</dc:creator>
	<dc:creator>Saputra, Jonathan</dc:creator>
	<dc:subject xml:lang="en-US">Direct Displacement Based Design (DDBD)</dc:subject>
	<dc:subject xml:lang="en-US">Shear Wall</dc:subject>
	<dc:subject xml:lang="en-US">Structural Response</dc:subject>
	<dc:description xml:lang="en-US">Shear walls' placement in specific positions could develop different structural responses to the building and affect the structure's strength to the received lateral loads. This research aims to find the variations in the shear walls' placement on the structure's response under the Direct Displacement Based Design (DDBD) method. The object of this research is the model of a 10-story reinforced concrete building located in Yogyakarta, Indonesia. Modelling of building structures is carried out in this study with four variations of shear wall placement. First, the walls are located at every building's corner. The shear wall is then positioned in the core of the building, where the apertures have shrunk. Then, the shear wall is located on the edge of the building. Last, the shear wall is located on the edge of the building. ANOVA method is used to analyze the significant difference, i.e., variations in the walls' placement. This research indicates the significant differences in the x-direction shear force and the y-direction moment The shear walls are suggested to be placed according to the building's condition and the earthquake ground site's class to produce an optimal structure to resist earthquake loads.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2022-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/12959</dc:identifier>
	<dc:identifier>10.22441/sinergi.2022.2.009</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 26 No. 2 (2022); 201-212</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/12959/5753</dc:relation>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/12959/11165</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 SINERGI</dc:rights>
</oai_dc:dc>