Jurnal
SINTA 1
High-temperature failure of steel boiler tube secondary superheater in a power plant
Sinergi · Vol. 27 No. 1 (2023) · hlm. 1–6
ISSN 2460-1217, 1410-2331
Terbit 2023-01-13
Penerbit Universitas Mercu Buana
Bahasa eng
Abstrak
This work investigated the failure analysis of the boiler tube secondary superheats in a power plant utility. The tube was composed of low carbon steel with 2.25Cr-1Mo addition, which was ruptured after a 26 h working test. The investigation of the tube’s failure was performed through several analysis, such as microstructure, elemental analysis, and mechanical test. It was found the abrupt increase in the operating temperature as the primary factor of the material degradation of the tube. The microstructure analysis shows the existence of elongated grain with the formation of microcracks on the grain boundaries, indicating the exceeded stress applied in the material. The hoop stress in the ruptured tube was 42.47 MPa, which is higher than the allowable stress of 23.5 MPa at 605 °C. Furthermore, the equiaxed grain was observed in the unruptured tube, implying the microstructural change after exposure at high temperatures.
Jaringan kolaborasi para penulis
14 penulis ·
37 tautan kepenulisan bersama
· 25 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mercu Buana University Nano Center Indonesia IPB University National Institute for Materials Science National Research and Innovation Agency Telkom University Ungku Omar Polytechnic Organisasi lain
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">High-temperature failure of steel boiler tube secondary superheater in a power plant</dc:title>
<dc:creator>Akbar, Sulthoni</dc:creator>
<dc:creator>Nursyifaulkhair, Desrilia</dc:creator>
<dc:creator>Nurdiwijayanto, Leanddas</dc:creator>
<dc:creator>Noviyanto, Alfian</dc:creator>
<dc:creator>Rochman, Nurul Taufiqu</dc:creator>
<dc:subject xml:lang="en-US">Boiler</dc:subject>
<dc:subject xml:lang="en-US">Ruptured</dc:subject>
<dc:subject xml:lang="en-US">Degradation</dc:subject>
<dc:subject xml:lang="en-US">Microstructure</dc:subject>
<dc:subject xml:lang="en-US">Hoop stress</dc:subject>
<dc:description xml:lang="en-US">This work investigated the failure analysis of the boiler tube secondary superheats in a power plant utility. The tube was composed of low carbon steel with 2.25Cr-1Mo addition, which was ruptured after a 26 h working test. The investigation of the tube’s failure was performed through several analysis, such as microstructure, elemental analysis, and mechanical test. It was found the abrupt increase in the operating temperature as the primary factor of the material degradation of the tube. The microstructure analysis shows the existence of elongated grain with the formation of microcracks on the grain boundaries, indicating the exceeded stress applied in the material. The hoop stress in the ruptured tube was 42.47 MPa, which is higher than the allowable stress of 23.5 MPa at 605 °C. Furthermore, the equiaxed grain was observed in the unruptured tube, implying the microstructural change after exposure at high temperatures. </dc:description>
<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
<dc:date>2023-01-13</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:format>application/vnd.openxmlformats-officedocument.wordprocessingml.document</dc:format>
<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/14268</dc:identifier>
<dc:identifier>10.22441/sinergi.2023.1.001</dc:identifier>
<dc:source xml:lang="en-US">SINERGI; Vol. 27 No. 1 (2023); 1-6</dc:source>
<dc:source>2460-1217</dc:source>
<dc:source>1410-2331</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/14268/6470</dc:relation>
<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/14268/11214</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 SINERGI</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Akbar, S., Nursyifaulkhair, D., Nurdiwijayanto, L., Noviyanto, A., & Rochman, N. T. (2023). High-temperature failure of steel boiler tube secondary superheater in a power plant. Sinergi, 27(1), 1–6. https://doi.org/10.22441/sinergi.2023.1.001
Salin
IEEE
S. Akbar, D. Nursyifaulkhair, L. Nurdiwijayanto, A. Noviyanto, and N. T. Rochman, “High-temperature failure of steel boiler tube secondary superheater in a power plant,” Sinergi, vol. 27, no. 1, pp. 1–6, 2023, doi: 10.22441/sinergi.2023.1.001.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.