Comprehensive seismic evaluation of existing buildings using ASCE 41-17 standards

Sinergi · Vol. 29 No. 3 (2025) · hlm. 645–660

DOI
10.22441/sinergi.2025.3.008
ISSN
2460-1217, 1410-2331
Terbit
2025-09-02
Penerbit
Universitas Mercu Buana
Bahasa
eng

Abstrak

This study addresses the lack of comprehensive seismic evaluations for eight-story reinforced concrete buildings in high-seismic zones, such as Jakarta, using the ASCE 41-17 standard. The research evaluates the seismic performance of a 35-year-old office building through a tiered analysis approach, including Tier 1, Tier 2, and Tier 3. The study aims to identify structural deficiencies and propose retrofitting measures to meet modern seismic standards. Defects in soft story behavior and overturning stability were among the five and fourteen items in the Tier 1 assessment that showed noncompliance. In Tier 2, linear analysis revealed critical ductility demands, with Demand-to-Capacity Ratios (DCR) exceeding permissible limits in most structural elements. The nonlinear pushover analysis conducted in Tier 3 revealed an insufficient structural capacity to withstand high seismic loads. Maximum inter-story drifts in the X and Y directions were 2.321% and 2.319%, respectively, surpassing Life Safety standards. The findings indicate that the building's seismic performance falls between the Life Safety and Collapse Prevention levels, emphasizing the urgent need for retrofitting to enhance its resilience. This research presents a comprehensive framework for integrating global standards and local seismic conditions to enhance the safety and performance of existing structures in high-risk areas.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 26 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Oky Bima PutraJakarta State Polytechnic3
Ilham Dwiputra RamadhanJakarta State Polytechnic3
Jasun Widiana PutraJakarta State Polytechnic2
Hanif Satria AjiJakarta State Polytechnic2
Alvin DunaufalJakarta State Polytechnic2
Mayda PahinggisJakarta State Polytechnic1
Mutia Hanuun Ufaira AkbarJakarta State Polytechnic1
Erlina YanuariniAfiliasi tidak diketahui1
Hanan YurizkaJakarta State Polytechnic1
Nadhila Ramadhani A.P.Jakarta State Polytechnic1
Annisaa Dina PuspitaJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comprehensive seismic evaluation of existing buildings using ASCE 41-17 standards</dc:title>
	<dc:creator>Rosyidah, Anis</dc:creator>
	<dc:creator>Dinda, Tree Irma</dc:creator>
	<dc:creator>Saputra, Jonathan</dc:creator>
	<dc:creator>Sucita, I Ketut</dc:creator>
	<dc:subject xml:lang="en-US">ASCE 41-17</dc:subject>
	<dc:subject xml:lang="en-US">Retrofitting</dc:subject>
	<dc:subject xml:lang="en-US">Seismic Performance</dc:subject>
	<dc:subject xml:lang="en-US">Structural Evaluation</dc:subject>
	<dc:subject xml:lang="en-US">Tier Analysis</dc:subject>
	<dc:description xml:lang="en-US">This study addresses the lack of comprehensive seismic evaluations for eight-story reinforced concrete buildings in high-seismic zones, such as Jakarta, using the ASCE 41-17 standard. The research evaluates the seismic performance of a 35-year-old office building through a tiered analysis approach, including Tier 1, Tier 2, and Tier 3. The study aims to identify structural deficiencies and propose retrofitting measures to meet modern seismic standards. Defects in soft story behavior and overturning stability were among the five and fourteen items in the Tier 1 assessment that showed noncompliance. In Tier 2, linear analysis revealed critical ductility demands, with Demand-to-Capacity Ratios (DCR) exceeding permissible limits in most structural elements. The nonlinear pushover analysis conducted in Tier 3 revealed an insufficient structural capacity to withstand high seismic loads. Maximum inter-story drifts in the X and Y directions were 2.321% and 2.319%, respectively, surpassing Life Safety standards. The findings indicate that the building's seismic performance falls between the Life Safety and Collapse Prevention levels, emphasizing the urgent need for retrofitting to enhance its resilience. This research presents a comprehensive framework for integrating global standards and local seismic conditions to enhance the safety and performance of existing structures in high-risk areas.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2025-09-02</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>application/vnd.openxmlformats-officedocument.wordprocessingml.document</dc:format>
	<dc:format>application/msword</dc:format>
	<dc:format>application/vnd.openxmlformats-officedocument.wordprocessingml.document</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/30747</dc:identifier>
	<dc:identifier>10.22441/sinergi.2025.3.008</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 29 No. 3 (2025); 645-660</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/30747/10040</dc:relation>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/30747/12164</dc:relation>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/30747/12212</dc:relation>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/30747/12213</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 SINERGI</dc:rights>
</oai_dc:dc>