Abstrak

Biodegradable magnesium implants have attracted significant attention in orthopedics due to their low density, biocompatibility, and natural degradability in the human body. However, their clinical application has been limited by an excessively rapid degradation rate, which may compromise mechanical stability and disrupt tissue healing. To address this challenge, surface coating has been explored as an effective strategy to control the degradation rate, improve corrosion resistance, and preserve the mechanical integrity of magnesium implants. This review analyzed and compared various coating materials and methods applied to magnesium-based implants, including polymers, ceramics, metals, and composites. Each material category was found to offer distinct advantages and limitations in terms of biocompatibility, corrosion protection, and mechanical reinforcement. Furthermore, the study highlighted that the choice of coating method-such as dip coating, physical vapor deposition, micro-arc oxidation, or electrodeposition-significantly affected the performance of the protective layer. A structured literature search and qualitative synthesis of recent studies published between 2020 and 2025 were conducted to assess coating performance, identify trends, and evaluate challenges in clinical translation. The findings indicated that composite and multilayer coatings provided the most promising balance of corrosion resistance, bioactivity, and mechanical strength, despite fabrication complexity. This review concluded that the development of multifunctional coatings and standardized testing protocols remains crucial for advancing the clinical application of magnesium-based biodegradable implants.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 32 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Semarang
  • State University of Malang
  • Mercu Buana University
  • Plekhanov Russian University of Economics
  • AGH University of Krakow
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Solikhin SolikhinAfiliasi tidak diketahui2
Septia LutfiAfiliasi tidak diketahui2
Hardiwinoto HardiwinotoUniversitas Muhammadiyah Semarang2
Primi ArtiningrumMercu Buana University1
Aji Prasetya WibawaState University of Malang1
Felix Andika DwiyantoAGH University of Krakow1
Agung Bella Putra UtamaState University of Malang1
Khurin NabilaState University of Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Coating materials to enhance the corrosion resistance of magnesium-based implants: a review</dc:title>
	<dc:creator>Saefudin, Slamet</dc:creator>
	<dc:creator>Purnomo, Purnomo</dc:creator>
	<dc:creator>Rusydi, Muhammad Omar</dc:creator>
	<dc:creator>Raharjo, Samsudi</dc:creator>
	<dc:creator>Anton, Kuzmin</dc:creator>
	<dc:creator>Pujianto, M. Edi</dc:creator>
	<dc:subject xml:lang="en-US">Biodegradable Materials</dc:subject>
	<dc:subject xml:lang="en-US">Corrosion Resistance</dc:subject>
	<dc:subject xml:lang="en-US">Magnesium Implants</dc:subject>
	<dc:subject xml:lang="en-US">Orthopedic Applications</dc:subject>
	<dc:subject xml:lang="en-US">Surface Coating</dc:subject>
	<dc:description xml:lang="en-US">Biodegradable magnesium implants have attracted significant attention in orthopedics due to their low density, biocompatibility, and natural degradability in the human body. However, their clinical application has been limited by an excessively rapid degradation rate, which may compromise mechanical stability and disrupt tissue healing. To address this challenge, surface coating has been explored as an effective strategy to control the degradation rate, improve corrosion resistance, and preserve the mechanical integrity of magnesium implants. This review analyzed and compared various coating materials and methods applied to magnesium-based implants, including polymers, ceramics, metals, and composites. Each material category was found to offer distinct advantages and limitations in terms of biocompatibility, corrosion protection, and mechanical reinforcement. Furthermore, the study highlighted that the choice of coating method-such as dip coating, physical vapor deposition, micro-arc oxidation, or electrodeposition-significantly affected the performance of the protective layer. A structured literature search and qualitative synthesis of recent studies published between 2020 and 2025 were conducted to assess coating performance, identify trends, and evaluate challenges in clinical translation. The findings indicated that composite and multilayer coatings provided the most promising balance of corrosion resistance, bioactivity, and mechanical strength, despite fabrication complexity. This review concluded that the development of multifunctional coatings and standardized testing protocols remains crucial for advancing the clinical application of magnesium-based biodegradable implants.  </dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2026-06-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/33565</dc:identifier>
	<dc:identifier>10.22441/sinergi.2026.2.005</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 30 No. 2 (2026); 371-384</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/33565/12481</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 SINERGI</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>