Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Hospital resilience in earthquake-prone regions: a novel evaluation of base isolation systems for structural and functional performance in West Lombok

Sinergi · Vol. 30 No. 3 (2026) · hlm. 879–888

DOI
10.22441/sinergi.2026.3.015
ISSN
2460-1217, 1410-2331
Terbit
2026-09-22
Penerbit
Universitas Mercu Buana
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Earthquakes pose a significant threat to hospital infrastructure, where uninterrupted functionality is critical for emergency response and post-disaster recovery. While base isolation systems have been widely recognized for reducing structural damage, their effectiveness in enhancing functional resilience remains insufficiently quantified. This study evaluates the seismic performance of three base isolation systems, Lead Rubber Bearings (LRB), High-Damping Rubber Bearings (HDRB), and Friction Pendulum Systems (FPS), applied to a representative hospital building in West Lombok using nonlinear finite-element analysis based on SNI 1726:2019 response-spectrum loading. Structural performance is assessed through key parameters, including base shear, natural period, inter-story drift, and lateral displacement. The results indicate that FPS provides the most significant performance improvement, reducing base shear by 35.6%, lateral displacement by 27.0%, and inter-story drift by 37.5%, while increasing the fundamental period by up to 692%. To address the limitations of conventional structural evaluation, this study introduces a quantitative Resilience Index (R) defined as the normalized reduction ratios of structural response parameters relative to the fixed-base condition. FPS achieves the highest resilience scores (R = 0.356 for base shear, 0.270 for displacement, and 0.375 for drift), outperforming HDRB and LRB systems. These improvements indicate enhanced structural robustness, which correlates with reduced expected downtime and improved immediate occupancy performance. The integration of structural and functional performance metrics represents a shift from conventional design approaches toward resilience-driven engineering decision-making. The findings demonstrate that base isolation systems, particularly FPS, significantly improve both structural safety and post-earthquake operational continuity of hospital facilities. Furthermore, the proposed resilience-based evaluation framework provides a scalable approach to integrating structural performance and functional recovery metrics into the seismic risk assessment of critical infrastructure, supporting resilience-based seismic design strategies for healthcare infrastructure in developing seismic regions.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Mataram
  • Universitas Gunung Rinjani
  • Meteorological, Climatological, And Geophysical Agency
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Didi Supriyadi AgustawijayaUniversity of Mataram1
Rian Mahendra TarunaMeteorological, Climatological, And Geophysical Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://publikasi.mercubuana.ac.id/index.php/sinergi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Hospital resilience in earthquake-prone regions: a novel evaluation of base isolation systems for structural and functional performance in West Lombok</dc:title>
	<dc:creator>Burhan, Lalu Ibrohim</dc:creator>
	<dc:creator>Kencanawati, Ni Nyoman</dc:creator>
	<dc:creator>Anshari, Buan</dc:creator>
	<dc:subject xml:lang="en-US">Base Isolation Systems</dc:subject>
	<dc:subject xml:lang="en-US">Earthquake-Prone Regions</dc:subject>
	<dc:subject xml:lang="en-US">Functional Recovery</dc:subject>
	<dc:subject xml:lang="en-US">Hospital Resilience</dc:subject>
	<dc:subject xml:lang="en-US">Structural Performance</dc:subject>
	<dc:description xml:lang="en-US">Earthquakes pose a significant threat to hospital infrastructure, where uninterrupted functionality is critical for emergency response and post-disaster recovery. While base isolation systems have been widely recognized for reducing structural damage, their effectiveness in enhancing functional resilience remains insufficiently quantified. This study evaluates the seismic performance of three base isolation systems, Lead Rubber Bearings (LRB), High-Damping Rubber Bearings (HDRB), and Friction Pendulum Systems (FPS), applied to a representative hospital building in West Lombok using nonlinear finite-element analysis based on SNI 1726:2019 response-spectrum loading. Structural performance is assessed through key parameters, including base shear, natural period, inter-story drift, and lateral displacement. The results indicate that FPS provides the most significant performance improvement, reducing base shear by 35.6%, lateral displacement by 27.0%, and inter-story drift by 37.5%, while increasing the fundamental period by up to 692%. To address the limitations of conventional structural evaluation, this study introduces a quantitative Resilience Index (R) defined as the normalized reduction ratios of structural response parameters relative to the fixed-base condition. FPS achieves the highest resilience scores (R = 0.356 for base shear, 0.270 for displacement, and 0.375 for drift), outperforming HDRB and LRB systems. These improvements indicate enhanced structural robustness, which correlates with reduced expected downtime and improved immediate occupancy performance. The integration of structural and functional performance metrics represents a shift from conventional design approaches toward resilience-driven engineering decision-making. The findings demonstrate that base isolation systems, particularly FPS, significantly improve both structural safety and post-earthquake operational continuity of hospital facilities. Furthermore, the proposed resilience-based evaluation framework provides a scalable approach to integrating structural performance and functional recovery metrics into the seismic risk assessment of critical infrastructure, supporting resilience-based seismic design strategies for healthcare infrastructure in developing seismic regions. </dc:description>
	<dc:publisher xml:lang="en-US">Universitas Mercu Buana</dc:publisher>
	<dc:date>2026-09-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/36392</dc:identifier>
	<dc:identifier>10.22441/sinergi.2026.3.015</dc:identifier>
	<dc:source xml:lang="en-US">SINERGI; Vol. 30 No. 3 (2026); 879-888</dc:source>
	<dc:source>2460-1217</dc:source>
	<dc:source>1410-2331</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/36392/12756</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 SINERGI</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>