Performance Comparison of Ground Source Heat Pump (GSHP) against Air Source Heat Pump (ASHP) for Domestic Applications: A case study in Perth, Australia

Teknomekanik · Vol. 4 No. 2 (2021) · hlm. 55–63

DOI
10.24036/teknomekanik.v4i2.11272
ISSN
2621-8720, 2621-9980
Terbit
2021-10-20
Penerbit
Universitas Negeri Padang
Bahasa
eng
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

The goal of this research is to evaluate the efficacy and practicality of installing a ground source heat pump (GSHP) with an air source heat pump (ASHP) in a residential setting. The results of this comparison were obtained by monitoring each of the systems in two almost identical residences in Perth, Western Australia. There is an open-loop groundwater system in the previous home. Each residence has one family whose air conditioning system has its own set of operational needs. The cooling capacity supplied and coefficient of performance (COP) as a function of seasonal changes in ambient temperatures were determined using data gathered from both residences over a two-year period. For both heating and cooling, the GSHP system COP was found to be greater than that of the ASHP system. Furthermore, these two performance measures were independent of ambient circumstances in the former, but they exhibit a noticeable ambient dependent trend in the latter. The GSHP had an average COP of 4.0 for heating, regardless of external conditions, while the ASHP COP ranged from 2.0 to 3.0. Conversely, the GSHP had an average COP of 3.2 for cooling, whereas the ASHP COP ranged from 1.4 to 2.9. It is found that GSHPs result in significant operational cost reductions and a significant decrease in greenhouse gas emissions when a borewell is part of a home.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 67 tautan kepenulisan bersama · 24 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • The University of Western Australia
  • Sriwijaya University
  • Universitas Tridinanti Palembang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Selvia AprilyantiUniversitas Tridinanti Palembang4
Irnanda PratiwiUniversitas Tridinanti Palembang2
Winny AndaliaUniversitas Tridinanti Palembang2
Hariman Al FaritzieUniversitas Tridinanti Palembang2
Srinivasan KandadaiThe University of Western Australia2
Harrini Mutiara HapsariSriwijaya University2
Debby Yulinar PermataSriwijaya University2
Justin SobeyThe University of Western Australia2
Kallan PhamThe University of Western Australia2
Yadi UtamaSriwijaya University1
Fitri HadiahSriwijaya University1
Muhammad SaidSriwijaya University1
Tuti Indah SariSriwijaya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Performance Comparison of Ground Source Heat Pump (GSHP) against Air Source Heat Pump (ASHP) for Domestic Applications:  A case study in Perth, Australia</dc:title>
	<dc:creator xml:lang="en">Aprianti, Tine</dc:creator>
	<dc:creator xml:lang="en">Tan, Evan</dc:creator>
	<dc:creator xml:lang="en">Diu, Chan</dc:creator>
	<dc:creator xml:lang="en">Sprivulis, Ben</dc:creator>
	<dc:creator xml:lang="en">Ryan, Greg</dc:creator>
	<dc:creator xml:lang="en">Srinivasan, Kandadai</dc:creator>
	<dc:creator xml:lang="en">Chua, Hui Tong</dc:creator>
	<dc:subject xml:lang="en">Ground Source Heat Pump</dc:subject>
	<dc:subject xml:lang="en">Air Source Heat Pump</dc:subject>
	<dc:subject xml:lang="en">Air Conditioning</dc:subject>
	<dc:subject xml:lang="en">Geothermal Application</dc:subject>
	<dc:subject xml:lang="en">Groundwater System</dc:subject>
	<dc:description xml:lang="en">The goal of this research is to evaluate the efficacy and practicality of installing a ground source heat pump (GSHP) with an air source heat pump (ASHP) in a residential setting. The results of this comparison were obtained by monitoring each of the systems in two almost identical residences in Perth, Western Australia. There is an open-loop groundwater system in the previous home. Each residence has one family whose air conditioning system has its own set of operational needs. The cooling capacity supplied and coefficient of performance (COP) as a function of seasonal changes in ambient temperatures were determined using data gathered from both residences over a two-year period. For both heating and cooling, the GSHP system COP was found to be greater than that of the ASHP system. Furthermore, these two performance measures were independent of ambient circumstances in the former, but they exhibit a noticeable ambient dependent trend in the latter. The GSHP had an average COP of 4.0 for heating, regardless of external conditions, while the ASHP COP ranged from 2.0 to 3.0. Conversely, the GSHP had an average COP of 3.2 for cooling, whereas the ASHP COP ranged from 1.4 to 2.9. It is found that GSHPs result in significant operational cost reductions and a significant decrease in greenhouse gas emissions when a borewell is part of a home.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Padang</dc:publisher>
	<dc:date>2021-10-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/112</dc:identifier>
	<dc:identifier>10.24036/teknomekanik.v4i2.11272</dc:identifier>
	<dc:source xml:lang="en">Teknomekanik; Vol. 4 No. 2 (2021): Regular Issue; 55-63</dc:source>
	<dc:source>2621-8720</dc:source>
	<dc:source>2621-9980</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/112/45</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2021 Tine Aprianti (Author)</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>