Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Process design and simulation study of an electricity generation plant utilizing low-grade wasted thermal energy using aspen Hysys software

Teknomekanik · Vol. 6 No. 1 (2023) · hlm. 29–36

DOI
10.24036/teknomekanik.v6i1.23872
ISSN
2621-8720, 2621-9980
Terbit
2023-06-30
Penerbit
Universitas Negeri Padang
Bahasa
eng
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

An analysis of the operational parameters of a small-scale electrical generation facility that uses the thermal energy contained in the flue gases from rubbish waste incineration is the goal of this study. To assess this system, the organic Rankine cycle (ORC) thermodynamic system was used. Since the organic fluid has a lower boiling point than water and can be evaporated with less thermal energy, it was chosen as a heat transfer medium instead of water. Aspen Hysys was utilized as a simulation tool, while R11 was used as the working fluid. To maximize the amount of available electrical output power, the plant's operational temperature, working fluid flow rate, and pressure are all maximized. According to the simulation's findings, flue gas may generate electric power between the ranges of 3.12 – 29.71 kW at working pressures between 2.5 and 3.5 bar and working fluid flow rates between 3.600 and 7200 kg/h when the temperature is between 50 and 95 oC. The system reaches a thermal efficiency of about 8.30 at 350 kPa of working fluid pressure.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 141 tautan kepenulisan bersama · 54 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Negeri Padang
  • State University of Medan
  • Universitas Sumatera Utara
  • University of Malaya
  • Universiti Sains Malaysia
  • Khon Kaen University
  • Tun Hussein Onn University of Malaysia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Waskito WaskitoUniversitas Negeri Padang4
Bisrul Hapis TambunanState University of Medan3
Mohamad Yusof IdroasUniversiti Sains Malaysia2
Eka DaryantoState University of Medan2
Nurin Wahidah Mohd ZulkifliUniversity of Malaya2
Taufiq Bin NurUniversitas Sumatera Utara2
Himsar AmbaritaUniversitas Sumatera Utara2
Enzo W.B SiahaanUniversitas Sumatera Utara2
Nelvi ErizonUniversitas Negeri Padang2
Primawati PrimawatiUniversitas Negeri Padang2
Refdinal RefdinalUniversitas Negeri Padang2
Andre KurniawanUniversitas Negeri Padang2
Mohamad Zamri ZainonAfiliasi tidak diketahui1
Riduwan RiduwanAfiliasi tidak diketahui1
Dina AmperaState University of Medan1
Zulkifl MatondangState University of Medan1
Tosawat SeetawanKhon Kaen University1
Mohd Zamri ZainonUniversity of Malaya1
Tulus Burhanuddin SitorusUniversitas Sumatera Utara1
Ilmi IlmiUniversitas Sumatera Utara1
Safri GunawanState University of Medan1
Hanafi HasanState University of Medan1
Tze Kiong TeeTun Hussein Onn University of Malaysia1
Rizky Ema WulansariUniversitas Negeri Padang1
Budi SyahriUniversitas Negeri Padang1
Yufrizal YufrizalUniversitas Negeri Padang1
Rimbawati RimbawatiUniversitas Muhammadiyah Sumatera Utara1
Sahala SiallaganState University of Medan1
Bonaraja PurbaState University of Medan1
Nurin Wahidah Mohd ZulkifliUniversity of Malaya1
Mohd Kamal KamarulzamanNational Defence University of Malaysia1
Putu Satria RinaldoUniversitas Negeri Padang1
Irzal IrzalUniversitas Negeri Padang1
Ahmad Halim SidiqUniversitas Negeri Padang1
Ar TrisyaldiUniversitas Negeri Padang1
Syahril SyahrilUniversitas Negeri Padang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 10 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Process design and simulation study of an electricity generation plant utilizing low-grade wasted thermal energy using aspen Hysys software</dc:title>
	<dc:creator xml:lang="en">Simanjuntak, Janter Pangaduan</dc:creator>
	<dc:creator xml:lang="en">Pakpahan, Binsar Maruli Tua</dc:creator>
	<dc:creator xml:lang="en">Purwantono, Purwantono</dc:creator>
	<dc:creator xml:lang="en">Al-attab, Khaled Ali</dc:creator>
	<dc:subject xml:lang="en">Waste thermal</dc:subject>
	<dc:subject xml:lang="en">Organic fluid</dc:subject>
	<dc:subject xml:lang="en">Rankine cycle</dc:subject>
	<dc:subject xml:lang="en">Electric power</dc:subject>
	<dc:subject xml:lang="en">Aspen Hysys</dc:subject>
	<dc:description xml:lang="en">An analysis of the operational parameters of a small-scale electrical generation facility that uses the thermal energy contained in the flue gases from rubbish waste incineration is the goal of this study. To assess this system, the organic Rankine cycle (ORC) thermodynamic system was used. Since the organic fluid has a lower boiling point than water and can be evaporated with less thermal energy, it was chosen as a heat transfer medium instead of water. Aspen Hysys was utilized as a simulation tool, while R11 was used as the working fluid. To maximize the amount of available electrical output power, the plant's operational temperature, working fluid flow rate, and pressure are all maximized. According to the simulation's findings, flue gas may generate electric power between the ranges of 3.12 – 29.71 kW at working pressures between 2.5 and 3.5 bar and working fluid flow rates between 3.600 and 7200 kg/h when the temperature is between 50 and 95 oC. The system reaches a thermal efficiency of about 8.30 at 350 kPa of working fluid pressure.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Padang</dc:publisher>
	<dc:date>2023-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/238</dc:identifier>
	<dc:identifier>10.24036/teknomekanik.v6i1.23872</dc:identifier>
	<dc:source xml:lang="en">Teknomekanik; Vol. 6 No. 1 (2023): Regular Issue; 29-36</dc:source>
	<dc:source>2621-8720</dc:source>
	<dc:source>2621-9980</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/238/69</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2023 Janter Pangaduan Simanjuntak, Binsar Maruli Tua Pakpahan, Purwantono Purwantono, Khaled Ali Al-attab (Author)</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>