Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 5

Evaluasi dan Optimalisasi Penyediaan Air Bersih Berbasis Masyarakat (Studi Kasus: Kawasan Langara Pesisir, Kab. Konawe Kepulauan)

Sultra Civil Engineering Journal (SCiEJ) · Vol. 5 No. 1 (2024) · pp. 241–253

DOI
10.54297/sciej.v5i1.593
ISSN
2716-1714
Published
2024-04-23
Publisher
Universitas Sulawesi Tenggara
Language
eng
License
creativecommons.org/licenses/by/4.0

Abstract

The Langara Coastal area is the economic center area of the capital city of Konawe Islands Regency. However, the provision of clean water as a basic need is still not fulfilled, this is because the source of clean water in the Langara Coastal Area currently still depends on Community Self-Help, as a result, water distribution is carried out in shifts. This research aims to determine air needs, the condition of the existing distribution network, and optimize the clean water distribution system. Air requirements are calculated using an analysis of population projections for 15 years. Analysis of pipe hydraulics using EPANET 2.2 Software, and air flow by gravity using PVC pipes. The analysis results show that the population in 2036 will be 1816 people with peak hour water demand of 4.13 l/sec. The condition of the existing distribution network shows that all Junctions have an average pressure of 9 atm. Meanwhile, the pipe with the highest speed at P3 is 0.47 m/s and the speed at P15 is 0.04 m/s, indicating that the existing conditions do not meet the technical criteria of Minister of PUPR Regulation No. 27/PRT/M/2016. So to increase the flow speed it is necessary to change the pipe dimensions at several points. In peak hour optimization simulations, the maximum speed occurs in pipes P2, P3, P4, and P10, namely 2.61 m/s, while the lowest speed occurs in pipe P21, namely 0.30 m/s. The results of this optimization are by the speed criteria in Minister of PUPR Regulation No.27/PRT/M/2016

Collaboration network of the authors

40 authors · 167 co-authorship links · 3 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Halu Oleo
  • Universitas Sembilanbelas November Kolaka
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Edward NgiiUniversitas Halu Oleo4
Ahmad Syarif SukriUniversitas Halu Oleo4
Agustan AgustanUniversitas Halu Oleo3
Tryantini Sundi PutriAffiliation unknown3
Fathur Rahman RustanUniversitas Sembilanbelas November Kolaka2
sulha sulhaAffiliation unknown2
La WelendoAffiliation unknown2
Adris Ade PutraAffiliation unknown2
Rini SriyaniAffiliation unknown2
Laode Muhammad FaisalUniversitas Halu Oleo1
Ishak BafadalUniversitas Halu Oleo1
Adris Ade PutraUniversitas Halu Oleo1
Sitti Nurjannah AhmadUniversitas Halu Oleo1
Fitriah S Fitriah SUniversitas Halu Oleo1
Romy TalanipaUniversitas Halu Oleo1
Reska Angjella MustarifAffiliation unknown1
Ikmal IkmalUniversitas Halu Oleo1
Idul Adha Zulhijja AhmadAffiliation unknown1
Umran SaritaAffiliation unknown1
Iksan Ade SaputraAffiliation unknown1
Muhammad Zukriyansyah SipaAffiliation unknown1
Muhammad Rabiul BahriAffiliation unknown1
Laode M Golok JayaAffiliation unknown1
Sitti Nurjannah AhmadAffiliation unknown1
Tahir AzikinAffiliation unknown1
Triantini. S. PutriAffiliation unknown1
Fitriah.S Fitriah.SAffiliation unknown1
RIdwansyah NuhunAffiliation unknown1
Lawalendo LawalendoAffiliation unknown1
Wiwin YudistiraAffiliation unknown1
Isra RoslianaAffiliation unknown1
Siti Nurjanah AhmadUniversitas Halu Oleo1
Muh. Febriansyah I. TanasaleAffiliation unknown1
Santi SantiAffiliation unknown1
Muh Thahir AzikinAffiliation unknown1
Al Amin Andi Rifai MalaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://jurnal-unsultra.ac.id/index.php/scej/oai, first harvested 30 Okt 2026, last seen 1 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Evaluasi dan Optimalisasi Penyediaan Air Bersih Berbasis Masyarakat (Studi Kasus: Kawasan Langara Pesisir, Kab. Konawe Kepulauan)</dc:title>
	<dc:creator>Darmawan, Ilham Kari</dc:creator>
	<dc:creator>Mangidi, Uniadi</dc:creator>
	<dc:creator>Muriadin, Muriadin</dc:creator>
	<dc:creator>Balaka, Rudi</dc:creator>
	<dc:description xml:lang="en-US">The Langara Coastal area is the economic center area of the capital city of Konawe Islands Regency. However, the provision of clean water as a basic need is still not fulfilled, this is because the source of clean water in the Langara Coastal Area currently still depends on Community Self-Help, as a result, water distribution is carried out in shifts. This research aims to determine air needs, the condition of the existing distribution network, and optimize the clean water distribution system. Air requirements are calculated using an analysis of population projections for 15 years. Analysis of pipe hydraulics using EPANET 2.2 Software, and air flow by gravity using PVC pipes. The analysis results show that the population in 2036 will be 1816 people with peak hour water demand of 4.13 l/sec. The condition of the existing distribution network shows that all Junctions have an average pressure of 9 atm. Meanwhile, the pipe with the highest speed at P3 is 0.47 m/s and the speed at P15 is 0.04 m/s, indicating that the existing conditions do not meet the technical criteria of Minister of PUPR Regulation No. 27/PRT/M/2016. So to increase the flow speed it is necessary to change the pipe dimensions at several points. In peak hour optimization simulations, the maximum speed occurs in pipes P2, P3, P4, and P10, namely 2.61 m/s, while the lowest speed occurs in pipe P21, namely 0.30 m/s. The results of this optimization are by the speed criteria in Minister of PUPR Regulation No.27/PRT/M/2016</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Sulawesi Tenggara</dc:publisher>
	<dc:date>2024-04-23</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal-unsultra.ac.id/index.php/scej/article/view/593</dc:identifier>
	<dc:identifier>10.54297/sciej.v5i1.593</dc:identifier>
	<dc:source xml:lang="en-US">Sultra Civil Engineering Journal (SCiEJ); Vol 5 No 1 (2024): Sultra Civil Engineering Journal (SCiEJ); 241-253</dc:source>
	<dc:source>2716-1714</dc:source>
	<dc:source>10.54297/sciej.v5i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal-unsultra.ac.id/index.php/scej/article/view/593/359</dc:relation>
	<dc:relation>10.54297/sciej.v5i1.593.g359</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Ilham Kari Darmawan, Uniadi Mangidi, Muriadin Muriadin, Rudi Balaka</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>