Abstrak

This study presents the analysis of thermodynamic behavior and energy efficiency of a vapor compression refrigeration system with two types of condensers: air-cooled (ACC) and water-cooled (WCC). The main objective is to assess the system performance by comparing the Coefficient of Performance (COP) and Energy Efficiency Ratio (EER) under both condenser configurations. During a 12-hour test period, data on refrigerant pressure, temperature, and electrical energy consumption were collected and analyzed. The results show that the WCC system outperforms the ACC system, showing a 5.7% increase in heat rejection and a 4.2% increase in cooling capacity. In addition, the WCC system exhibits a lower compressor duty cycle and consumes less electrical energy, resulting in a higher total EER of 5.658 compared to ACC of 1.945. These findings suggest that integrating a water-cooled condenser into a refrigeration system can significantly improve energy efficiency and reduce operating costs, making it a viable option for commercial applications in tropical regions.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 134 tautan kepenulisan bersama · 72 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Magelang
  • Politeknik Negeri Semarang
  • Universitas Negeri Padang
  • Diponegoro University
  • Indian Maritime University
  • Pancasila University
  • State University of Semarang
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad Latifur RochmanUniversitas Muhammadiyah Magelang11
R. ThirunavukkarasuAfiliasi tidak diketahui5
Dori YuvendaUniversitas Negeri Padang5
Deni Fajar FitriyanaState University of Semarang5
Januar Parlaungan SiregarUniversiti Malaysia Pahang Al-Sultan Abdullah5
Tuessi Ari PurnomoUniversitas Muhammadiyah Magelang4
Indra Chandra SetiawanPancasila University4
Asep Bayu Dani NandiyantoIndonesia University of Education4
Noto WidodoUniversitas Muhammadiyah Magelang3
Tezara CionitaINTI International University3
Saifudin SaifudinUniversitas Muhammadiyah Magelang3
Djoko Wahyu KarmiadjiNational Research and Innovation Agency2
Muchamad GozaliBadan Pengkajian dan Penerapan Teknologi2
Margana MarganaPoliteknik Negeri Semarang2
Marliyati MarliyatiPoliteknik Negeri Semarang2
Yusuf Dewantoro HerlambangPoliteknik Negeri Semarang2
Wahyu SulistiyoPoliteknik Negeri Semarang2
Nanang ApriandiPoliteknik Negeri Semarang2
Jin‐Cherng ShyuNational Kaohsiung University of Science and Technology2
Abdulkareem Sh. Mahdi Al‐ObaidiTaylor's University2
Hendry Y. NanlohyUniversitas Sains dan Teknologi Jayapura2
Sunaryo SunaryoUniversitas Sains Al-Qur'an2
Krismadinata KrismadinataUniversitas Negeri Padang2
Wawan PurwantoUniversitas Negeri Padang2
Suroto MunaharUniversitas Muhammadiyah Magelang2
Dhasa Ikrar SetyanansyachUniversitas Muhammadiyah Magelang1
Roni Muhammad SusantoUniversitas Muhammadiyah Magelang1
Bambang Hadi PriyantoAfiliasi tidak diketahui1
Arif Nur MiftachulAfiliasi tidak diketahui1
Ade BurhanudinAfiliasi tidak diketahui1
Bambang SeptianUniversitas Muhammadiyah Magelang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Vapor compression refrigeration system with air and water cooled condenser: Analysis of thermodynamic behavior and energy efficiency ratio</dc:title>
	<dc:creator xml:lang="en">Setiyo, Muji</dc:creator>
	<dc:creator xml:lang="en">Rusdjijati, Retno</dc:creator>
	<dc:creator xml:lang="en">Habibi, Ilham</dc:creator>
	<dc:creator xml:lang="en">Rochman, Muhamad Latifur</dc:creator>
	<dc:creator xml:lang="en">Purnomo, Bagiyo Condro</dc:creator>
	<dc:creator xml:lang="en">Pertiwi, Fungky Dyan</dc:creator>
	<dc:creator xml:lang="en">Waluyo, Budi</dc:creator>
	<dc:creator xml:lang="en">Ismail, Rifky</dc:creator>
	<dc:creator xml:lang="en">Kolakoti, Aditya</dc:creator>
	<dc:subject xml:lang="en">air cooled condenser</dc:subject>
	<dc:subject xml:lang="en">water cooled condenser</dc:subject>
	<dc:subject xml:lang="en">Energy Efficiency Ratio</dc:subject>
	<dc:subject xml:lang="en">coefficient of performance</dc:subject>
	<dc:subject xml:lang="en">thermodynamic behavior</dc:subject>
	<dc:description xml:lang="en">This study presents the analysis of thermodynamic behavior and energy efficiency of a vapor compression refrigeration system with two types of condensers: air-cooled (ACC) and water-cooled (WCC). The main objective is to assess the system performance by comparing the Coefficient of Performance (COP) and Energy Efficiency Ratio (EER) under both condenser configurations. During a 12-hour test period, data on refrigerant pressure, temperature, and electrical energy consumption were collected and analyzed. The results show that the WCC system outperforms the ACC system, showing a 5.7% increase in heat rejection and a 4.2% increase in cooling capacity. In addition, the WCC system exhibits a lower compressor duty cycle and consumes less electrical energy, resulting in a higher total EER of 5.658 compared to ACC of 1.945. These findings suggest that integrating a water-cooled condenser into a refrigeration system can significantly improve energy efficiency and reduce operating costs, making it a viable option for commercial applications in tropical regions.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Padang</dc:publisher>
	<dc:date>2024-12-14</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/319</dc:identifier>
	<dc:identifier>10.24036/teknomekanik.v7i2.31972</dc:identifier>
	<dc:source xml:lang="en">Teknomekanik; Vol. 7 No. 2 (2024): Regular Issue; 112-125</dc:source>
	<dc:source>2621-8720</dc:source>
	<dc:source>2621-9980</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://teknomekanik.ppj.unp.ac.id/index.php/teknomekanik/article/view/319/86</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Muji Setiyo, Retno Rusdjijati, Ilham Habibi, Muhamad Latifur Rochman, Bagiyo Condro Purnomo, Fungky Dyan Pertiwi, Budi Waluyo, Rifky Ismail, Aditya Kolakoti</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>