Abstrak

Introduction: Fire cases increase in residential buildings because short circuits, at dormitories are mostly affected by human factors. X university dormitory building is a place for 24 hours of students' activities with a lot of electricity consumption, bad behavior; overpowering extensions, and many flammable objects such as paper and furniture. Research objectives are to investigate the appropriateness and mapping needs of fire protection systems with regulations. Methods: The research is a semi quantitative analysis. Primary data is conducted with observations by using a checklist form that refers to the regulations and results of managers' interviews. The obtained data are categorized into good with suitability >79-100%, moderate ≥60%-79% and poor <60%. Result: The appropriateness of the active fire protection system is under 60% or in the poor category. The appropriateness of the fire extinguisher is 47.77%, the hydrant is 58.75%, the alarm is 18.75% and the heat detector is 35.90%. There is no sprinkler installation in the dormitory building and no commitment from the top management regarding occupational safety and health. Fire extinguisher's need is 10 tubes per floor, the number of hydrants have been fulfilled, alarm requires an additional 1 unit on each floor and a heat detector requires a total of 114 units. Conclusion: The active fire protection system is still under 60% (poor category) and no maintenances. Based on the aforementioned mapping results, it needs to add the number of piece equipment according to the regulations and maintenance efforts.Keywords: active fire protection system, dormitory, mapping

Jaringan kolaborasi para penulis

18 penulis · 55 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Darussalam Gontor
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Prince of Songkla University
  • Universitas Airlangga
  • Institut Agama Islam Negeri Kendari
  • Universitas Jember
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ramadhan Dwi SaputraUniversitas Jember2
Aisy RahmaniaUniversity of Darussalam Gontor2
Munawar MunawarInstitut Agama Islam Negeri Kendari1
Tofan Agung Eka PrasetyaUniversitas Airlangga1
Sarawuth ChesohPrince of Songkla University1
Apiradee LimPrince of Songkla University1
Don McNeilPrince of Songkla University1
Azizan RamliUniversiti Malaysia Pahang Al-Sultan Abdullah1
Azim Azuan OsmanUniversiti Malaysia Pahang Al-Sultan Abdullah1
Dian Afif ArifahUniversity of Darussalam Gontor1
Norwahida YaakubUniversiti Malaysia Pahang Al-Sultan Abdullah1
Nur Fazhilah Abdul RazakUniversiti Malaysia Pahang Al-Sultan Abdullah1
Sisca Mayang PhuspaUniversity of Darussalam Gontor1
Mohd Shahril Abu HanifahUniversiti Malaysia Pahang Al-Sultan Abdullah1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/IJOSH/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Mapping Analysis of Active Fire Protection System on Dormitory Building in X University</dc:title>
	<dc:creator>Rosanti, Eka</dc:creator>
	<dc:creator>Irawan, Selamet Ujang</dc:creator>
	<dc:creator>Diannita, Rindang</dc:creator>
	<dc:creator>Taufik, Muhammad Rifki</dc:creator>
	<dc:description xml:lang="en-US">Introduction: Fire cases increase in residential buildings because short circuits, at dormitories are mostly affected by human factors. X university dormitory building is a place for 24 hours of students' activities with a lot of electricity consumption, bad behavior; overpowering extensions, and many flammable objects such as paper and furniture. Research objectives are to investigate the appropriateness and mapping needs of fire protection systems with regulations. Methods: The research is a semi quantitative analysis. Primary data is conducted with observations by using a checklist form that refers to the regulations and results of managers' interviews. The obtained data are categorized into good with suitability &amp;gt;79-100%, moderate ≥60%-79% and poor &amp;lt;60%. Result: The appropriateness of the active fire protection system is under 60% or in the poor category. The appropriateness of the fire extinguisher is 47.77%, the hydrant is 58.75%, the alarm is 18.75% and the heat detector is 35.90%. There is no sprinkler installation in the dormitory building and no commitment from the top management regarding occupational safety and health. Fire extinguisher's need is 10 tubes per floor, the number of hydrants have been fulfilled, alarm requires an additional 1 unit on each floor and a heat detector requires a total of 114 units. Conclusion: The active fire protection system is still under 60% (poor category) and no maintenances. Based on the aforementioned mapping results, it needs to add the number of piece equipment according to the regulations and maintenance efforts.Keywords: active fire protection system, dormitory, mapping</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2021-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/IJOSH/article/view/24433</dc:identifier>
	<dc:identifier>10.20473/ijosh.v10i2.2021.240-246</dc:identifier>
	<dc:source xml:lang="en-US">The Indonesian Journal of Occupational Safety and Health; Vol. 10 No. 2 (2021): The Indonesian Journal of Occupational Safety and Health; 240-246</dc:source>
	<dc:source>2540-7872</dc:source>
	<dc:source>2301-8046</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/IJOSH/article/view/24433/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 The Indonesian Journal Of Occupational Safety and Health</dc:rights>
</oai_dc:dc>