Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Indoor Air Factors Affecting the Growth of Microorganism in an Indonesian Gas Company's Dormitory

The Indonesian Journal Of Occupational Safety and Health · Vol. 11 No. 3 (2022) · hlm. 445–453

DOI
10.20473/ijosh.v11i3.2022.445-453
ISSN
2540-7872, 2301-8046
Terbit
2022-11-10
Penerbit
Universitas Airlangga
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Introduction: Mold may affect the Indoor Air Quality (IAQ) in workplace dormitories. This study aims to investigate indoor air factors that affect molds growth in a dormitory of an LNG Company in Indonesia. Several indoor air determinant factors, including relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration were assessed against the growth of microorganism colonies. Methods: This study was a cross-sectional study using a 2 (two)-stage Andersen sampler based on NIOSH 0800 Bioaerosol Sampling Method for Indoor Air Quality for viable bioaerosol sampling. Bioaerosol samples were collected from 50 indoor, corridor, and outdoor sampling points. The total colony count for bioaerosols (TCC) was then determined (CFU/m3). Ten indoor air quality parameters, i.e., relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration, were measured. Results: The average mold colony concentration in the dormitory rooms was higher (703.1 CFU/m3) than the maximum standard issued by the Ministry of Health of the Republic of Indonesia (< 700 CFU/m3) while the relative humidity was very high (84.4% RH on average), with a direct relation between the humidity and the mold colony concentration. A significant correlation was also identified between mold colony concentration, wet temperature, and CO2 concentration. Conclusion: Significant correlations between bioaerosols, relative humidity, wet temperature, and indoor CO2 concentration indicate insufficient ventilation and poor indoor air quality in the dormitory.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 11 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aulia Indar AyuningtyasUniversity of Indonesia1
William WilliamUniversity of Indonesia1
Hayu Weka PrasetyaUniversity of Indonesia1
Mahendra Duta AprionoUniversity of Indonesia1
Edo Nur YusufUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/IJOSH/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Indoor Air Factors Affecting the Growth of Microorganism in an Indonesian Gas Company's Dormitory</dc:title>
	<dc:creator>Nasri, Sjahrul Meizar</dc:creator>
	<dc:creator>Athari, Asduki D. </dc:creator>
	<dc:creator> Hastiti, Laksita Ri</dc:creator>
	<dc:creator>Putri, Fiori Amelia</dc:creator>
	<dc:subject xml:lang="en-US">carbon dioxide</dc:subject>
	<dc:subject xml:lang="en-US"> humidity</dc:subject>
	<dc:subject xml:lang="en-US"> indoor air</dc:subject>
	<dc:subject xml:lang="en-US">mold</dc:subject>
	<dc:subject xml:lang="en-US"> temperature</dc:subject>
	<dc:description xml:lang="en-US">Introduction: Mold may affect the Indoor Air Quality (IAQ) in workplace dormitories. This study aims to investigate indoor air factors that affect molds growth in a dormitory of an LNG Company in Indonesia. Several indoor air determinant factors, including relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration were assessed against the growth of microorganism colonies. Methods: This study was a cross-sectional study using a 2 (two)-stage Andersen sampler based on NIOSH 0800 Bioaerosol Sampling Method for Indoor Air Quality for viable bioaerosol sampling. Bioaerosol samples were collected from 50 indoor, corridor, and outdoor sampling points. The total colony count for bioaerosols (TCC) was then determined (CFU/m3). Ten indoor air quality parameters, i.e., relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration, were measured. Results: The average mold colony concentration in the dormitory rooms was higher (703.1 CFU/m3) than the maximum standard issued by the Ministry of Health of the Republic of Indonesia (&amp;lt; 700 CFU/m3) while the relative humidity was very high (84.4% RH on average), with a direct relation between the humidity and the mold colony concentration. A significant correlation was also identified between mold colony concentration, wet temperature, and CO2 concentration. Conclusion: Significant correlations between bioaerosols, relative humidity, wet temperature, and indoor CO2 concentration indicate insufficient ventilation and poor indoor air quality in the dormitory.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2022-11-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/IJOSH/article/view/38113</dc:identifier>
	<dc:identifier>10.20473/ijosh.v11i3.2022.445-453</dc:identifier>
	<dc:source xml:lang="en-US">The Indonesian Journal of Occupational Safety and Health; Vol. 11 No. 3 (2022): The Indonesian Journal of Occupational Safety and Health; 445-453</dc:source>
	<dc:source>2540-7872</dc:source>
	<dc:source>2301-8046</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/IJOSH/article/view/38113/22906</dc:relation>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>