Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Validity of pleural lactate dehydrogenase measurements in assessment of pleural effusions

Universa Medicina · Vol. 31 No. 2 (2012) · hlm. 105–112

DOI
10.18051/UnivMed.2012.v31.105-112
ISSN
2407-2230, 1907-3062
Terbit
2012-08-14
Penerbit
Faculty of Medicine, Universitas Trisakti
Bahasa
eng

Abstrak

Background Pleural effusions are classified into transudates and exudates based on Light’s criteria, but the main disadvantage of Light’s criteria is the misclassification of transudates as exudates in about 20% of cases. The aim of this study was to determine the validity of various biochemical parameters to differentiate pleural exudates and transudates.MethodsAn observational study to evaluate diagnostics tests was conducted at the emergency department of Persahabatan Hospital, Jakarta, from September 2010 until December 2011. In total, 119 patients with pleural effusion were evaluated. Simultaneous pleural effusion and blood samples were examined for lactate dehydrogenase (LDH), total protein, cholesterol and albumin, with the clinical diagnosis as the gold standard. ResultsThere were 104 exudative and 15 transudative pleural effusions. Light’s criteria achieved a higher overall accuracy (sensitivity 97%, specificity 80%, accuracy 95%). The optimum cut off values were pleural fluid to serum ratio of LDH 0.4 (sensitivity 95%, specificity 87%, accuracy 94%) and pleural fluid LDH of 178 IU/L (sensitivity 92%, specificity 87%, accuracy 92%). Pleural fluid cholesterol was 50 mg/dL (sensitivity 89%, specificity 53%, accuracy 85%), pleural fluid to serum cholesterol ratio 0.41 (sensitivity 75%, specificity 53%, accuracy 72%) and serum-effusion albumin gradient 1.3 g/dL (sensitivity 91%, specificity 73%, accuracy 89%). Combination of biochemical tests did not improve sensitivity or accuracy.ConclusionsLight’s criteria remain superior to other biochemical tests, but the new cut off values of LDH pleural fluid to serum ratio of 0.4 and pleural fluid LDH of 178 IU/L appears to yield a slight improvement in diagnostic accuracy.

Kata kunci

Jaringan kolaborasi para penulis

29 penulis · 133 tautan kepenulisan bersama · 68 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Universitas Trisakti
  • Pembuluh Darah Harapan Kita
  • Fatmawati Hospital
  • Universitas Nurul Jadid
  • State University of Semarang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
ROBIATUL ADAWIYAHUniversitas Nurul Jadid1
Jamal ZainiUniversity of Indonesia1
Abul A’la Al MaududiUniversity of Indonesia1
Zahrah AnnisaUniversity of Indonesia1
Denny Grecius SiregarUniversity of Indonesia1
Findra SetianingrumUniversity of Indonesia1
Mulyati TugiranUniversity of Indonesia1
Ridhawati SjamUniversity of Indonesia1
Anna RozaliyaniUniversity of Indonesia1
Sita AndariniUniversity of Indonesia1
Amal Chalik SjaafUniversity of Indonesia1
Masyitoh MasyitohState University of Semarang1
Zhafirah SalsabilaUniversity of Indonesia1
Donna AdrianiUniversitas Trisakti1
Patwa AmaniUniversitas Trisakti1
Erlin ListiyaningsihPembuluh Darah Harapan Kita1
Rianto SetiabudyUniversity of Indonesia1
Idrus AlwiRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Alida Roswita HarahapUniversity of Indonesia1
Astuti GiantiniRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Ina Susianti TimanRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Rahajuningsih S DharmaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Nuri Dyah IndrasariRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Siskawati SuparminUniversity of Indonesia1
Windy SaharPembuluh Darah Harapan Kita1
Renan SukmawanPembuluh Darah Harapan Kita1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://univmed.org/ejurnal/index.php/medicina/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Validity of pleural lactate dehydrogenase measurements  in assessment of pleural effusions</dc:title>
	<dc:creator xml:lang="en">Syahruddin, Elisna</dc:creator>
	<dc:creator xml:lang="en">Partakusuma, Lia G.</dc:creator>
	<dc:creator xml:lang="en">Khairani, Rita</dc:creator>
	<dc:subject xml:lang="en">Lactate dehydrogenase</dc:subject>
	<dc:subject xml:lang="en">Light’s criteria</dc:subject>
	<dc:subject xml:lang="en">albumin</dc:subject>
	<dc:subject xml:lang="en">pleural effusion</dc:subject>
	<dc:description xml:lang="en">Background Pleural effusions are classified into transudates and exudates based on Light’s criteria, but the main disadvantage of Light’s criteria is the misclassification of transudates as exudates in about 20% of cases. The aim of this study was to determine the validity of various biochemical parameters to differentiate pleural exudates and transudates.MethodsAn observational study to evaluate diagnostics tests was conducted at the emergency department of Persahabatan Hospital, Jakarta, from September 2010 until December 2011. In total, 119 patients with pleural effusion were evaluated. Simultaneous pleural effusion and blood samples were examined for lactate dehydrogenase (LDH), total protein, cholesterol and albumin, with the clinical diagnosis as the gold standard. ResultsThere were 104 exudative and 15 transudative pleural effusions. Light’s criteria achieved a higher overall accuracy (sensitivity 97%, specificity 80%, accuracy 95%). The optimum cut off values were pleural fluid to serum ratio of LDH 0.4 (sensitivity 95%, specificity 87%, accuracy 94%) and pleural fluid LDH of 178 IU/L (sensitivity 92%, specificity 87%, accuracy 92%). Pleural fluid cholesterol was 50 mg/dL (sensitivity 89%, specificity 53%, accuracy 85%), pleural fluid to serum cholesterol ratio 0.41 (sensitivity 75%, specificity 53%, accuracy 72%) and serum-effusion albumin gradient 1.3 g/dL (sensitivity 91%, specificity 73%, accuracy 89%). Combination of biochemical tests did not improve sensitivity or accuracy.ConclusionsLight’s criteria remain superior to other biochemical tests, but the new cut off values of LDH pleural fluid to serum ratio of 0.4 and pleural fluid LDH of 178 IU/L appears to yield a slight improvement in diagnostic accuracy.</dc:description>
	<dc:publisher xml:lang="en">Faculty of Medicine, Universitas Trisakti</dc:publisher>
	<dc:date>2012-08-14</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://univmed.org/ejurnal/index.php/medicina/article/view/102</dc:identifier>
	<dc:identifier>10.18051/UnivMed.2012.v31.105-112</dc:identifier>
	<dc:source xml:lang="en">Universa Medicina; Vol. 31 No. 2 (2012); 105-112</dc:source>
	<dc:source>2407-2230</dc:source>
	<dc:source>1907-3062</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://univmed.org/ejurnal/index.php/medicina/article/view/102/113</dc:relation>
	<dc:relation>10.18051/univmed.v31i2.102</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2015 Elisna Syahruddin, Lia G. Partakusuma, Rita Khairani</dc:rights>
</oai_dc:dc>