Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Kinerja Biosensor Konduktometri Berbasis (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos

VALENSI · Vol. ume No. 2 (2015) · hlm. 84–90

DOI
10.15408/jkv.v0i0.3156
ISSN
2548-3013, 2460-6065
Terbit
2015-11-30
Penerbit
Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University
Bahasa
eng

Abstrak

The performance of biosensor is based on the hydrolysis reaction of organophosphorus compounds catalyzed by organophosphate hydrolase (OPH), produce H+ and the other ionic species that increase conductance on the surface of electrode. In this research, OPH was immobilized by crosslinking on chitosan–glutaraldehyde membrane on the (Screen Printed Carbon Electrode) SPCE surface. Measurements were carried out at the range concentration 0 to 3.0 ppm of organophosphate, the range of pH 7.0 to 9.0 and 5–25 mL of enzyme. The result showed that optimum performances were obtained at 25 mL of OPH, pH 8.5, with the sensitivity for dizinon, malathion, chlorpirifos and profenofos is 1.353 mS/ppm, 1.270 mS/ppm, 1.230 mS/ppm dan 1.77 mS/ppm respectively and 0.97; 1.03; 0.98; 0.97 of LOD. DOI:http://dx.doi.org/10.15408/jkv.v0i0.3156.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 21 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Barlah RumhayatiUniversity of Brawijaya1
Chandrawati CahyaniUniversity of Brawijaya1
Soebiantoro SoebiantoroUniversity of Brawijaya1
Alfita SavitriUniversity of Brawijaya1
Hermin SulistyartiUniversity of Brawijaya1
Asnaili Alfi NurillahUniversity of Brawijaya1
Arie SrihardyastutieUniversity of Brawijaya1
Anna RoosdianaUniversity of Brawijaya1
Qonitah FardiyahUniversity of Brawijaya1
Rizki SugiriUniversity of Brawijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://journal.uinjkt.ac.id/index.php/valensi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Kinerja Biosensor Konduktometri Berbasis  (Screen Printed Carbon Electrode) SPCE––Kitosan untuk Deteksi Diazinon, Malation, Klorpirifos dan Profenofos</dc:title>
	<dc:creator xml:lang="en">Isvani, Nuzulul Kurniawan</dc:creator>
	<dc:creator xml:lang="en">Mulyasuryani, Ani</dc:creator>
	<dc:creator xml:lang="en">Prasetyawan, Sasangka</dc:creator>
	<dc:subject xml:lang="en">Conductometric biosensor</dc:subject>
	<dc:subject xml:lang="en">organophosphate pesticide</dc:subject>
	<dc:subject xml:lang="en">organofosfat hydrolase</dc:subject>
	<dc:subject xml:lang="en">SPCE (screen printed carbon electrode)</dc:subject>
	<dc:description xml:lang="en">The performance of biosensor is based on the hydrolysis reaction of organophosphorus compounds catalyzed by organophosphate hydrolase (OPH), produce H+ and the other ionic species that increase conductance on the surface of electrode. In this research, OPH was immobilized by crosslinking on chitosan–glutaraldehyde membrane on the (Screen Printed Carbon Electrode) SPCE surface. Measurements were carried out at the range concentration 0 to 3.0 ppm of organophosphate, the range of pH 7.0 to 9.0 and 5–25 mL of enzyme. The result showed that optimum performances were obtained at 25 mL of OPH, pH 8.5, with the sensitivity for dizinon, malathion, chlorpirifos and profenofos is 1.353 mS/ppm, 1.270 mS/ppm, 1.230 mS/ppm dan 1.77 mS/ppm respectively and 0.97; 1.03; 0.98; 0.97 of LOD. DOI :http://dx.doi.org/10.15408/jkv.v0i0.3156.  </dc:description>
	<dc:publisher xml:lang="en">Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University</dc:publisher>
	<dc:date>2015-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.uinjkt.ac.id/index.php/valensi/article/view/3156</dc:identifier>
	<dc:identifier>10.15408/jkv.v0i0.3156</dc:identifier>
	<dc:source xml:lang="en">Jurnal Kimia Valensi; Jurnal Kimia VALENSI Volume 1, No. 2, November 2015; 84-90</dc:source>
	<dc:source>2548-3013</dc:source>
	<dc:source>2460-6065</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.uinjkt.ac.id/index.php/valensi/article/view/3156/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2019 Nuzulul Kurniawan Isvani, Ani Mulyasuryani, Sasangka Prasetyawan</dc:rights>
</oai_dc:dc>