Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Nonenzymatic Sensor Based on Glassy Carbon Electrode Modified by Platinum Nanoparticles Decorated Reduced Graphene Oxide for Glucose Detection in Human Urine

VALENSI · Vol. ume No. 2 (2024) · hlm. 215–228

DOI
10.15408/jkv.v10i2.40035
ISSN
2548-3013, 2460-6065
Terbit
2024-12-16
Penerbit
Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University
Bahasa
eng

Abstrak

This research aims to develop a sensitive and selective nonenzymatic electrochemical sensor for glucose detection using a glassy carbon electrode modified with platinum nanoparticles (PtNPs) decorated on reduced graphene oxide (RGO). The structural properties and surface morphology of PtNPs/RGO composite were characterized using Raman spectroscopy and scanning electron microscopy (SEM). In addition, cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed to investigate glucose measurements in human urine samples. The developed sensor shows an increasing anodic peak of glucose with a linear response at a concentration range from 10 to 1000 µM, with a detection limit of 5 µM. The proposed sensor also demonstrated good reproducibility, indicated by the value of relative standard deviation (%RSD) of 3.9%, and maintained its current response over seven consecutive measurements. Moreover, the proposed sensor exhibited high selectivity for glucose detection against several potential interferences, such as potassium (K+), chloride (Cl−), magnesium (Mg2+), ascorbic acid, dopamine, and urea, with recovery values of 96-102%, which are acceptable within the analytical range. Furthermore, this proposed sensor successfully detected glucose in human urine samples, and their concentrations were not significantly different when measured with a commercial glucose sensor.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 137 tautan kepenulisan bersama · 72 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • IPB University
  • Universitas Trisakti
  • National Research and Innovation Agency
  • Universitas Pamulang
  • Universiti Teknologi MARA
  • Indonesian Institute of Sciences
  • Flinders University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Novik NurhidayatIndonesian Institute of Sciences5
Henny PurwaningsihIPB University2
Ali Aulia GhozaliIPB University2
Min RahminiwatiIPB University2
Nampiah SukarnoIPB University2
Mashuri WaiteUniversity of Hawaiʻi at Mānoa2
Wendi Nurul FadillahIPB University2
Novriyandi HanifIPB University2
Rut Novalia Rahmawati SianiparIPB University2
Dyah Iswantini PradonoIPB University1
Selvitia UlandariAfiliasi tidak diketahui1
Alfiah AlifAfiliasi tidak diketahui1
Amalyah FebryantiUniversitas Islam Negeri Alauddin Makassar1
Fitriani IndahsariIPB University1
Akhiruddin MadduIPB University1
Sri SugiartiIPB University1
Cecep KusmanaIPB University1
TrivadilaAfiliasi tidak diketahui1
Komar SutriahIPB University1
Suminar Setiati AchmadiIPB University1
Christopher M. M. FrancoFlinders University1
Wei Yan ZhangFlinders University1
Edy Jamal TuheteruUniversitas Trisakti1
Suliestyah SuliestyahUniversitas Trisakti1
Ririn YuliantiUniversitas Trisakti1
Christin PalitUniversitas Trisakti1
Caroline Claudia YomakiUniversitas Trisakti1
Ridwan FirdausUniversitas Pamulang1
Euis FilailaIndonesian Institute of Sciences1
Rhahmasari IsmetUniversitas Pamulang1
Nesha AdeliaNational Research and Innovation Agency1
Andrian JoviantoNational Research and Innovation Agency1
Hanifah HanifahUniversitas Pamulang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://journal.uinjkt.ac.id/index.php/valensi/oai, pertama di-harvest 10 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Nonenzymatic Sensor Based on Glassy Carbon Electrode Modified by Platinum Nanoparticles Decorated Reduced Graphene Oxide for Glucose Detection in Human Urine</dc:title>
	<dc:creator xml:lang="en">Nisa, Ulfiatun</dc:creator>
	<dc:creator xml:lang="en">Iswantini, Dyah</dc:creator>
	<dc:creator xml:lang="en">Ahmad, Shahrul Nizam</dc:creator>
	<dc:creator xml:lang="en">Mahat, Mohd Muzamir</dc:creator>
	<dc:creator xml:lang="en">Putra, Budi Riza</dc:creator>
	<dc:creator xml:lang="en">Saskito, Dinda Iryawati Bedy</dc:creator>
	<dc:creator xml:lang="en">Wahyuni, Wulan Tri</dc:creator>
	<dc:subject xml:lang="en">Electrochemical sensors</dc:subject>
	<dc:subject xml:lang="en">glucose</dc:subject>
	<dc:subject xml:lang="en">platinum nanoparticles</dc:subject>
	<dc:subject xml:lang="en">reduced graphene oxide</dc:subject>
	<dc:subject xml:lang="en">water environment</dc:subject>
	<dc:description xml:lang="en">This research aims to develop a sensitive and selective nonenzymatic electrochemical sensor for glucose detection using a glassy carbon electrode modified with platinum nanoparticles (PtNPs) decorated on reduced graphene oxide (RGO). The structural properties and surface morphology of PtNPs/RGO composite were characterized using Raman spectroscopy and scanning electron microscopy (SEM). In addition, cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed to investigate glucose measurements in human urine samples. The developed sensor shows an increasing anodic peak of glucose with a linear response at a concentration range from 10 to 1000 µM, with a detection limit of 5 µM. The proposed sensor also demonstrated good reproducibility, indicated by the value of relative standard deviation (%RSD) of 3.9%, and maintained its current response over seven consecutive measurements. Moreover, the proposed sensor exhibited high selectivity for glucose detection against several potential interferences, such as potassium (K+), chloride (Cl−), magnesium (Mg2+), ascorbic acid, dopamine, and urea, with recovery values of 96-102%, which are acceptable within the analytical range. Furthermore, this proposed sensor successfully detected glucose in human urine samples, and their concentrations were not significantly different when measured with a commercial glucose sensor.</dc:description>
	<dc:publisher xml:lang="en">Department of Chemistry, Faculty of Science and Technology Syarif Hidayatullah Jakarta State Islamic University</dc:publisher>
	<dc:date>2024-12-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.uinjkt.ac.id/index.php/valensi/article/view/40035</dc:identifier>
	<dc:identifier>10.15408/jkv.v10i2.40035</dc:identifier>
	<dc:source xml:lang="en">Jurnal Kimia Valensi; Jurnal Kimia VALENSI,  Volume 10, No. 2, November 2024; 215 - 228</dc:source>
	<dc:source>2548-3013</dc:source>
	<dc:source>2460-6065</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.uinjkt.ac.id/index.php/valensi/article/view/40035/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Ulfiatun Nisa, Dyah Iswantini, Budi Riza Putra, Mohd Muzamir Mahat, Shahrul Nizam Ahmad, Dinda Iryawati Bedy Saskito, Wulan Tri Wahyuni</dc:rights>
</oai_dc:dc>