MOTOR INDUKSI SEBAGAI GENERATOR (MISG)

Metropilar - Jurnal Ilmiah Fakultas Teknik · Vol. 6 No. 1 (2015)

ISSN
1693-6205
Published
2015-12-24
Publisher
Universitas Halu Oleo
Language
eng

Abstract

The Induce Motor as Generator (MISG) is induction motor operated by generator. MISG are a lot of applied in The Power Plant of Micro hydro (PLTMh). This Research Target is to control potentials voltage used the contactor and ballast load. This controller has simple technology so that it is applied in PLTMh. The Research done by determining characteristic of high voltage output MISG function of load at constant input energy. The Controller design based on it’s characteristic. The Research done in Laboratory of Transmission and Distribution of Majors of Electrotechnic FT-UNHAS. The Result of research shows that manageable output MISG voltage at about from 198 volt to 231 volt. If without controller, so voltage of output MISG about 220 volt to 335 volt. With utilization of voltage Controller also minimize the percentage of unbalance voltage and also frequency reach. Key words: motor,induksi, tegangan, generator

Collaboration network of the authors

No co-authors found in Melola yet.

Metadata source: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/metropilar/oai, first harvested 30 Okt 2026, last seen 1 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">MOTOR INDUKSI SEBAGAI GENERATOR (MISG)</dc:title>
	<dc:creator>Utina, Adyson</dc:creator>
	<dc:description xml:lang="en-US">The Induce Motor as Generator (MISG) is induction motor operated by generator. MISG are a lot of applied in The Power Plant of Micro hydro (PLTMh).   This Research Target is to control potentials voltage used the contactor and ballast load. This controller has simple technology so that it is applied in PLTMh. The Research done by determining characteristic of high voltage output MISG function of load at constant input energy. The Controller design based on it’s characteristic. The Research done in Laboratory of Transmission and Distribution of Majors of Electrotechnic FT-UNHAS. The Result of research shows that manageable output MISG voltage at about from 198 volt   to 231 volt. If without controller, so voltage of output MISG about 220 volt to 335 volt. With utilization of voltage Controller also minimize the percentage of unbalance voltage and also frequency reach. Key words: motor,induksi, tegangan, generator</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Halu Oleo</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2015-12-24</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.uho.ac.id/index.php/metropilar/article/view/444</dc:identifier>
	<dc:source xml:lang="en-US">Metropilar - Jurnal Ilmiah Fakultas Teknik; Vol 6, No 1 (2008): Metropilar</dc:source>
	<dc:source>1693-6205</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.uho.ac.id/index.php/metropilar/article/view/444/284</dc:relation>
</oai_dc:dc>