Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Hyper parameter tuning based gradient boosting algorithm for detection of diabetic retinopathy: an analytical review

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 2 (2022) · hlm. 814–824

DOI
10.11591/eei.v11i2.3559
ISSN
2089-3191, 2302-9285
Terbit
2022-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The pipelines of approaches for classifying diabetic retinopathy were examined in this study. The effort entails developing appropriate transformations and estimators that can be used to automate the process of diabetic retinopathy detection. The segmentation of the blood vessels was done using a hybrid algorithm that uses Otsu and median filter to get the region of interest. Further, ten classifiers were investigated in order to develop an automated pipeline for diabetic retinopathy detection. The ten classifiers were reviewed based on earlier work in a similar setting and on an exploration of new ways for identifying diabetic retinopathy. To overcome the challenge of low volume of dataset, data argumentation was done so that a generic classifier can be configured. Extensive hyper parameter tuning was performed, and it was shown that the gradient boosting approach is the most stable technique for detecting diabetic retinopathy. This was validated using a 10K fold cross validation method on many metrics (accuracy, recall, precision, and v-measure score). Hyper-parameter tuning helped in achieving accuracy of 0.96.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 11 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Chitkara University
  • Universidad de Oviedo
  • Lord Buddha Education Foundation
  • Aryabhatta Knowledge University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Vicente García‐DíazUniversidad de Oviedo2
Jyotir Moy ChatterjeeLord Buddha Education Foundation1
Vishal DuttAryabhatta Knowledge University1
Sushil Kumar NarangChitkara University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Hyper parameter tuning based gradient boosting algorithm for detection of diabetic retinopathy: an analytical review</dc:title><dc:creator>Parul Datta</dc:creator><dc:creator>Prasenjit Das</dc:creator><dc:creator>Abhishek Kumar</dc:creator><dc:subject>diabetic retinopathy detection</dc:subject><dc:subject>gradient boosting</dc:subject><dc:subject>hyperparameter optimization</dc:subject><dc:subject>blood vessel segmentation</dc:subject><dc:subject>Otsu thresholding</dc:subject><dc:subject>median filter</dc:subject><dc:subject>data augmentation</dc:subject><dc:subject>automated medical image classification</dc:subject><dc:subject>classifier comparison</dc:subject><dc:description xml:lang="en">The pipelines of approaches for classifying diabetic retinopathy were examined in this study. The effort entails developing appropriate transformations and estimators that can be used to automate the process of diabetic retinopathy detection. The segmentation of the blood vessels was done using a hybrid algorithm that uses Otsu and median filter to get the region of interest. Further, ten classifiers were investigated in order to develop an automated pipeline for diabetic retinopathy detection. The ten classifiers were reviewed based on earlier work in a similar setting and on an exploration of new ways for identifying diabetic retinopathy. To overcome the challenge of low volume of dataset, data argumentation was done so that a generic classifier can be configured. Extensive hyper parameter tuning was performed, and it was shown that the gradient boosting approach is the most stable technique for detecting diabetic retinopathy. This was validated using a 10K fold cross validation method on many metrics (accuracy, recall, precision, and v-measure score). Hyper-parameter tuning helped in achieving accuracy of 0.96.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i2.3559</dc:identifier><dc:identifier>10.11591/eei.v11i2.3559</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 2 (2022); 814-824</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3559/2554</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>