Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimal distributed generation placement using artificial intelligence for improving active radial distribution system

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 5 (2021) · hlm. 2345–2354

DOI
10.11591/eei.v10i5.2949
ISSN
2089-3191, 2302-9285
Terbit
2021-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

There are several profits of distributed generator (DG) units which are believed for improving the safety of the distribution power grids. However, these profits can be maximized by ensuring optimum sizing and positioning of DG units because an arbitrary location of DG units may adversely affect and jeopardize power grids which could contribute to maximising of power loss and degradation of the voltage profile. Therefore, several approaches were suggested to ensure optimum position and size of DGs. The primary aim of this article is for establishing technique for optimum scheduling and operating of DG to lessen power loss, revamp voltage profile and overall network reliability. Artificial intelligence method called particle swarm optimization (PSO) is utilized for finding the best site and size of DG to lessen power loss and boost the voltage profile. In this paper, IEEE 33 distribution system is utilized to display applicability of PSO. The results of the PSO are compared with the results gotten by other methods in the literature. Finally, the results show that the PSO is superior than the other methods.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Al-Furat Al-Awsat Technical University
  • Sunni Endowment Diwan
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ahmed S. KashkoolAl-Furat Al-Awsat Technical University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimal distributed generation placement using artificial intelligence for improving active radial distribution system</dc:title><dc:creator>Fadhel A. Jumaa</dc:creator><dc:creator>Omar Muhammed Neda</dc:creator><dc:creator>Mustafa A. Mhawesh</dc:creator><dc:subject>distributed generation placement</dc:subject><dc:subject>distributed generation sizing</dc:subject><dc:subject>particle swarm optimization</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>power loss reduction</dc:subject><dc:subject>voltage profile improvement</dc:subject><dc:subject>network reliability</dc:subject><dc:subject>IEEE 33-bus system</dc:subject><dc:description xml:lang="en">There are several profits of distributed generator (DG) units which are believed for improving the safety of the distribution power grids. However, these profits can be maximized by ensuring optimum sizing and positioning of DG units because an arbitrary location of DG units may adversely affect and jeopardize power grids which could contribute to maximising of power loss and degradation of the voltage profile. Therefore, several approaches were suggested to ensure optimum position and size of DGs. The primary aim of this article is for establishing technique for optimum scheduling and operating of DG to lessen power loss, revamp voltage profile and overall network reliability. Artificial intelligence method called particle swarm optimization (PSO) is utilized for finding the best site and size of DG to lessen power loss and boost the voltage profile. In this paper, IEEE 33 distribution system is utilized to display applicability of PSO. The results of the PSO are compared with the results gotten by other methods in the literature. Finally, the results show that the PSO is superior than the other methods.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i5.2949</dc:identifier><dc:identifier>10.11591/eei.v10i5.2949</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 5 (2021); 2345-2354</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2949/2302</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>