Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Induction motor harmonic reduction using space vector modulation algorithm

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 2 (2020) · hlm. 452–465

DOI
10.11591/eei.v9i2.1682
ISSN
2089-3191, 2302-9285
Terbit
2020-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

The vector control was proposed as an alternative to the scalar control for AC machines control. Vector control provide high operation performance in steady state and transient operation. However, the variable switching frequency of vector control causes high flux and torque ripples which lead to an acoustical noise and degrade the performance of the control scheme. The insertion of the space vector modulation was a very useful solution to reduce the high ripples level inspite of its complexity. Numerical simulation results obtained in MATLAB/Simulink show the good dynamic performance of the proposed vector control technique and the effectiveness of the proposed sensorless strategy in the presence of the sudden load torque basing on the integral backstepping approach capabilities on instant perturbation rejection.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 39 tautan kepenulisan bersama · 25 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • University of Hassan II Casablanca
  • Hassania School of Public Works
  • Centre National de la Recherche Scientifique
  • Universitas Ahmad Dahlan
  • Université Sultan Moulay Slimane
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ahmed AbbouMohammed V University9
Mohamed MoutchouUniversity of Hassan II Casablanca5
Youssef MajdoubMohammed V University4
Rachid El AkhrifMohammed V University3
Souad TayaneUniversity of Hassan II Casablanca3
Alfian Ma’arifUniversitas Ahmad Dahlan3
Mohamed BararaCentre National de la Recherche Scientifique2
Kamal BayoudeUniversity of Hassan II Casablanca2
Farid OufqirUniversité Sultan Moulay Slimane2
Mounir DerriHassania School of Public Works1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Induction motor harmonic reduction using space vector modulation algorithm</dc:title><dc:creator>Yassine Zahraoui</dc:creator><dc:creator>Mohamed Akherraz</dc:creator><dc:creator>Chaymae Fahassa</dc:creator><dc:creator>Sara Elbadaoui</dc:creator><dc:subject>induction motor</dc:subject><dc:subject>harmonic compensation</dc:subject><dc:subject>space vector modulation</dc:subject><dc:subject>vector control</dc:subject><dc:subject>flux ripple</dc:subject><dc:subject>torque ripple</dc:subject><dc:subject>sensorless control</dc:subject><dc:subject>integral backstepping</dc:subject><dc:subject>load torque disturbance rejection</dc:subject><dc:subject>switching frequency</dc:subject><dc:description xml:lang="en">The vector control was proposed as an alternative to the scalar control for AC machines control. Vector control provide high operation performance in steady state and transient operation. However, the variable switching frequency of vector control causes high flux and torque ripples which lead to an acoustical noise and degrade the performance of the control scheme. The insertion of the space vector modulation was a very useful solution to reduce the high ripples level inspite of its complexity. Numerical simulation results obtained in MATLAB/Simulink show the good dynamic performance of the proposed vector control technique and the effectiveness of the proposed sensorless strategy in the presence of the sudden load torque basing on the integral backstepping approach capabilities on instant perturbation rejection.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i2.1682</dc:identifier><dc:identifier>10.11591/eei.v9i2.1682</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 2 (2020); 452-465</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1682/1332</dc:relation></oai_dc:dc>