Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 6 (2020) · hlm. 2213–2221

DOI
10.11591/eei.v9i6.2258
ISSN
2089-3191, 2302-9285
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA) is one of the most extensively employed technique to monitor its degradation. An extraction method is customarily required to extract the resistive component from the total leakage current. The existing methods to extract the resistive current are complex and less accurate. Therefore, this paper describes a simple and accurate circuit-based method to extract the resistive current using equivalent model and measured leakage current of the arrester. The accuracy of the proposed method is validated through experimental results on ABB’s 120 kV surge arrester, EMTP and QuickField software simulations. The performance of the method is also analyzed and verified experimentally on 72, 180 and 240 kV rated ABB’s surge arresters. The obtained results of resistive leakage current have shown the maximum error of 0.001%. Simple and easier computational steps with higher accuracy are the key benefits of the proposed technique.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 89 tautan kepenulisan bersama · 44 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Andalas University
  • NED University of Engineering and Technology
  • Robert Gordon University
  • Jubail Industrial College
  • University of Kuala Lumpur
  • Universidad Técnica Federico Santa María
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Chin‐Leong WooiUniversity of Technology Malaysia5
Mehrdad MokhtariUniversity of Technology Malaysia4
Ali I ElgayarUniversity of Technology Malaysia2
Noor Azlinda AhmadUniversity of Technology Malaysia2
Behnam SalimiUniversity of Technology Malaysia2
Ali I. El GayarAfiliasi tidak diketahui2
Nurul Aini BaniUniversity of Technology Malaysia1
Firdaus Muhammad‐SukkiRobert Gordon University1
Abdullahi Abubakar Mas’udJubail Industrial College1
Mohd Nabil MuhtazaruddinUniversity of Technology Malaysia1
Siti Hawa Abu-BakarUniversity of Kuala Lumpur1
Siti Armiza Mohd ArisUniversity of Technology Malaysia1
Siti Zura A. JalilUniversity of Technology Malaysia1
Hazilah Mad KaidiUniversity of Technology Malaysia1
Sharipah Alwiah Syed Abd RahamanUniversity of Technology Malaysia1
Jorge Alfredo Ardila ReyUniversidad Técnica Federico Santa María1
Ahmad Muhyiddin YusofUniversiti Malaysia Perlis1
Abdul RajabAndalas University1
Novizon NovizonAndalas University1
Aulia AuliaAndalas University1
Eka Putra WaldiAndalas University1
Darwison DarwisonAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester</dc:title><dc:creator>Amir Hesam Khavari</dc:creator><dc:creator>Abdullah Munir</dc:creator><dc:creator>Zulkurnain Abdul‐Malek</dc:creator><dc:subject>metal oxide surge arrester</dc:subject><dc:subject>resistive leakage current</dc:subject><dc:subject>equivalent circuit model</dc:subject><dc:subject>condition assessment</dc:subject><dc:description xml:lang="en">Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA) is one of the most extensively employed technique to monitor its degradation. An extraction method is customarily required to extract the resistive component from the total leakage current. The existing methods to extract the resistive current are complex and less accurate. Therefore, this paper describes a simple and accurate circuit-based method to extract the resistive current using equivalent model and measured leakage current of the arrester. The accuracy of the proposed method is validated through experimental results on ABB’s 120 kV surge arrester, EMTP and QuickField software simulations. The performance of the method is also analyzed and verified experimentally on 72, 180 and 240 kV rated ABB’s surge arresters. The obtained results of resistive leakage current have shown the maximum error of 0.001%. Simple and easier computational steps with higher accuracy are the key benefits of the proposed technique.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i6.2258</dc:identifier><dc:identifier>10.11591/eei.v9i6.2258</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 6 (2020); 2213-2221</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2258/1807</dc:relation></oai_dc:dc>