Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 2 (2020)

DOI
10.11591/eei.v9i2.2101
ISSN
2089-3191, 2302-9285
Terbit
2020-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Taking the advantages offered by smart high-performance electronic devices, transradial prosthesis for upper-limb amputees was developed and tested. It is equipped with sensing devices and actuators allowing hand movements; myoelectric signals are detected by Myo armband with 8 ElectroMyoGraphic (EMG) electrodes, a 9-axis Inertial Measurement Unit (IMU) and Bluetooth Low Energy (BLE) module. All data are received through HM-11 BLE transceiver by Arduino board which processes them and drives actuators. Raspberry Pi board controls a touchscreen display, providing user a feedback related to prosthesis functioning and sends EMG and IMU data, gathered via the armband, to cloud platform thus allowing orthopedic during rehabilitation period, to monitor users’ improvements in real time. A GUI software integrating a machine learning algorithm was implemented for recognizing flexion/extension/rest gestures of user fingers. The algorithm performances were tested on 9 male subjects (8 able-bodied and 1 subject affected by upper-limb amelia), demonstrating high accuracy and fast responses.

Kata kunci

Jaringan kolaborasi para penulis

18 penulis · 56 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Salento
  • Universidad Panamericana
  • Hashemite University
  • Isra University
  • Yarmouk University
  • John Paul II Catholic University of Lublin
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ramiro VelázquezUniversidad Panamericana7
Nicola Ivan GiannoccaroUniversity of Salento4
Ricardo Macías-QuijasUniversidad Panamericana3
A. Lay-EkuakilleUniversity of Salento3
Stefano CapocciaUniversity of Salento2
Marzia LuceriUniversity of Salento2
Bassam O. Al-NaamiHashemite University2
Yahia Z. RawashHashemite University2
Abdel-Razzak M. Al-hinnawiIsra University2
Awad Al‐ZabenYarmouk University2
Sergio StrazzellaAfiliasi tidak diketahui2
Donato CafagnaUniversity of Salento2
Carolina Del-Valle-SotoUniversidad Panamericana1
Rafał LizutJohn Paul II Catholic University of Lublin1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees</dc:title><dc:creator>Federico Gaetani</dc:creator><dc:creator>Roberto De Fazio</dc:creator><dc:creator>Giovanni Antonio Zappatore</dc:creator><dc:creator>Paolo Visconti</dc:creator><dc:subject>myoelectric prosthesis</dc:subject><dc:subject>transradial prosthesis</dc:subject><dc:subject>upper limb amputation</dc:subject><dc:subject>inertial measurement unit</dc:subject><dc:subject>Bluetooth Low Energy</dc:subject><dc:subject>gesture recognition</dc:subject><dc:subject>Arduino</dc:subject><dc:subject>Raspberry Pi</dc:subject><dc:subject>Myo armband</dc:subject><dc:subject>real-time user feedback</dc:subject><dc:description xml:lang="en">Taking the advantages offered by smart high-performance electronic devices, transradial prosthesis for upper-limb amputees was developed and tested. It is equipped with sensing devices and actuators allowing hand movements; myoelectric signals are detected by Myo armband with 8 ElectroMyoGraphic (EMG) electrodes, a 9-axis Inertial Measurement Unit (IMU) and Bluetooth Low Energy (BLE) module. All data are received through HM-11 BLE transceiver by Arduino board which processes them and drives actuators. Raspberry Pi board controls a touchscreen display, providing user a feedback related to prosthesis functioning and sends EMG and IMU data, gathered via the armband, to cloud platform thus allowing orthopedic during rehabilitation period, to monitor users’ improvements in real time. A GUI software integrating a machine learning algorithm was implemented for recognizing flexion/extension/rest gestures of user fingers. The algorithm performances were tested on 9 male subjects (8 able-bodied and 1 subject affected by upper-limb amelia), demonstrating high accuracy and fast responses.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i2.2101</dc:identifier><dc:identifier>10.11591/eei.v9i2.2101</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 2 (2020)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2101/1970</dc:relation></oai_dc:dc>