Jurnal
SINTA 1
A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees
Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 2 (2020)
ISSN 2089-3191, 2302-9285
Terbit 2020-04-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Taking the advantages offered by smart high-performance electronic devices, transradial prosthesis for upper-limb amputees was developed and tested. It is equipped with sensing devices and actuators allowing hand movements; myoelectric signals are detected by Myo armband with 8 ElectroMyoGraphic (EMG) electrodes, a 9-axis Inertial Measurement Unit (IMU) and Bluetooth Low Energy (BLE) module. All data are received through HM-11 BLE transceiver by Arduino board which processes them and drives actuators. Raspberry Pi board controls a touchscreen display, providing user a feedback related to prosthesis functioning and sends EMG and IMU data, gathered via the armband, to cloud platform thus allowing orthopedic during rehabilitation period, to monitor users’ improvements in real time. A GUI software integrating a machine learning algorithm was implemented for recognizing flexion/extension/rest gestures of user fingers. The algorithm performances were tested on 9 male subjects (8 able-bodied and 1 subject affected by upper-limb amelia), demonstrating high accuracy and fast responses.
Jaringan kolaborasi para penulis
18 penulis ·
56 tautan kepenulisan bersama
· 30 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Salento Universidad Panamericana Hashemite University Isra University Yarmouk University John Paul II Catholic University of Lublin Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees</dc:title><dc:creator>Federico Gaetani</dc:creator><dc:creator>Roberto De Fazio</dc:creator><dc:creator>Giovanni Antonio Zappatore</dc:creator><dc:creator>Paolo Visconti</dc:creator><dc:subject>myoelectric prosthesis</dc:subject><dc:subject>transradial prosthesis</dc:subject><dc:subject>upper limb amputation</dc:subject><dc:subject>inertial measurement unit</dc:subject><dc:subject>Bluetooth Low Energy</dc:subject><dc:subject>gesture recognition</dc:subject><dc:subject>Arduino</dc:subject><dc:subject>Raspberry Pi</dc:subject><dc:subject>Myo armband</dc:subject><dc:subject>real-time user feedback</dc:subject><dc:description xml:lang="en">Taking the advantages offered by smart high-performance electronic devices, transradial prosthesis for upper-limb amputees was developed and tested. It is equipped with sensing devices and actuators allowing hand movements; myoelectric signals are detected by Myo armband with 8 ElectroMyoGraphic (EMG) electrodes, a 9-axis Inertial Measurement Unit (IMU) and Bluetooth Low Energy (BLE) module. All data are received through HM-11 BLE transceiver by Arduino board which processes them and drives actuators. Raspberry Pi board controls a touchscreen display, providing user a feedback related to prosthesis functioning and sends EMG and IMU data, gathered via the armband, to cloud platform thus allowing orthopedic during rehabilitation period, to monitor users’ improvements in real time. A GUI software integrating a machine learning algorithm was implemented for recognizing flexion/extension/rest gestures of user fingers. The algorithm performances were tested on 9 male subjects (8 able-bodied and 1 subject affected by upper-limb amelia), demonstrating high accuracy and fast responses.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i2.2101</dc:identifier><dc:identifier>10.11591/eei.v9i2.2101</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 2 (2020)</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2101/1970</dc:relation></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
20 sitasi
Crossref
Terindeks
lewat DOI
5 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Gaetani, F., Fazio, R. D., Zappatore, G. A., & Visconti, P. (2020). A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees. Bulletin of Electrical Engineering and Informatics, 9(2). https://doi.org/10.11591/eei.v9i2.2101
Salin
IEEE
F. Gaetani, R. D. Fazio, G. A. Zappatore, and P. Visconti, “A prosthetic limb managed by sensors-based electronic system: Experimental results on amputees,” Bulletin of Electrical Engineering and Informatics, vol. 9, no. 2, 2020, doi: 10.11591/eei.v9i2.2101.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.