Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A new T-circuit model of wind turbine generator for power system steady state studies

Bulletin of Electrical Engineering and Informatics · Vol. 10 No. 2 (2021) · hlm. 550–558

DOI
10.11591/eei.v10i2.2306
ISSN
2089-3191, 2302-9285
Terbit
2021-03-16
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Modeling of wind power plant (WPP) is a crucial issue in power system studies. In this paper, a new model of WPP for steady state (i.e. load flow) studies is proposed. Similar to the previous T-circuit based models, it is also developed based on equivalent T-circuit of the WPP induction generator. However, unlike in the previous models, the mathematical formulation of the new model is shorter and less complicated. Moreover, the derivation of the model in the present work is also much simpler. Only minimal mathematical operations are required in the process. Furthermore, the rotor voltage value of the WPP induction generator is readily available as an output of the proposed new model. This rotor voltage value can be used as a basis to calculate the induction generator slip. Validity of the new method is tested on a representative 9-bus electrical power system installed with WPP. Comparative studies between the proposed method (new model) and other method (previous model) are also presented

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 28 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ayong HiendroTanjungpura University5
Ismail YusufTanjungpura University4
Fitriah HusinAfiliasi tidak diketahui2
Purwoharjono PurwoharjonoTanjungpura University2
F. Trias Pontia WigyariantoTanjungpura University2
Junaidi JunaidiTanjungpura University2
M. Iqbal ArsyadTanjungpura University1
Managam RajagukgukTanjungpura University1
Syaifurrahman SyaifurrahmanTanjungpura University1
Fitriah FitriahTanjungpura University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A new T-circuit model of wind turbine generator for power system steady state studies</dc:title><dc:creator>Rudy Gianto</dc:creator><dc:creator>Kho Hie Khwee</dc:creator><dc:subject>wind turbine generator</dc:subject><dc:subject>induction generator</dc:subject><dc:subject>power flow analysis</dc:subject><dc:subject>steady-state analysis</dc:subject><dc:subject>power system modeling</dc:subject><dc:description xml:lang="en">Modeling of wind power plant (WPP) is a crucial issue in power system studies. In this paper, a new model of WPP for steady state (i.e. load flow) studies is proposed. Similar to the previous T-circuit based models, it is also developed based on equivalent T-circuit of the WPP induction generator. However, unlike in the previous models, the mathematical formulation of the new model is shorter and less complicated. Moreover, the derivation of the model in the present work is also much simpler. Only minimal mathematical operations are required in the process. Furthermore, the rotor voltage value of the WPP induction generator is readily available as an output of the proposed new model. This rotor voltage value can be used as a basis to calculate the induction generator slip. Validity of the new method is tested on a representative 9-bus electrical power system installed with WPP. Comparative studies between the proposed method (new model) and other method (previous model) are also presented</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-03-16</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i2.2306</dc:identifier><dc:identifier>10.11591/eei.v10i2.2306</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 2 (2021); 550-558</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2306/2100</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>