Akses terbuka
Jurnal
SINTA 1
Wireless body-area network monitoring with ZigBee, 5G and 5G with MIMO for outdoor environments
Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 2 (2022) · hlm. 893–900
ISSN 2089-3191, 2302-9285
Terbit 2022-04-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Wireless body area network (WBAN) works near or inside the human body and is characterized by its accuracy in sending and receiving data. It works for long hours and must be low in energy consumption. One of its problems is that the transmission and reception distance is few and does not exceed a few meters. We worked on simulations based on a network consisting of ZigBee or fifth-generation (5G) and 5G with multiple-input and multiple-output (MIMO) nodes to deliver information to the center (hospital) at a 2.4 to 2.8 or 5 GHz frequency to solve this problem. Suppose the sensors are connected to the Arduino, which in turn is connected to the transmitter connection. The proposed method transmits data obtained from the sensor that touched the patient by multi-node to the hospital. The suggested method shows the best scenario to reduce energy consumption based on the number of active nodes. Based on the results obtained, we have noticed that ZigBee devices reduce energy use, perform better, and significantly extend the life of the nodes. While 5G devices increased the response speed in transferring data. In addition, MIMO antennas have the advantage of adding more stability in the connection between nodes.
Jaringan kolaborasi para penulis
18 penulis ·
74 tautan kepenulisan bersama
· 46 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Middle Technical University Iraqi University University of Kufa Al-Furat Al-Awsat Technical University Mustansiriyah University Al-Bayan University Kohat University of Science and Technology Organisasi lain Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Wireless body-area network monitoring with ZigBee, 5G and 5G with MIMO for outdoor environments</dc:title><dc:creator>Ahmed Mohammed Q. AL-Asadi</dc:creator><dc:creator>Karrar Shakir Muttair</dc:creator><dc:creator>Ahmed Ghanim Wadday</dc:creator><dc:creator>Mahmood Farhan Mosleh</dc:creator><dc:subject>wireless body area networks</dc:subject><dc:subject>ZigBee</dc:subject><dc:subject>5G</dc:subject><dc:subject>MIMO antenna</dc:subject><dc:subject>energy consumption</dc:subject><dc:subject>outdoor wireless communication</dc:subject><dc:subject>patient monitoring</dc:subject><dc:subject>sensor networks</dc:subject><dc:description xml:lang="en">Wireless body area network (WBAN) works near or inside the human body and is characterized by its accuracy in sending and receiving data. It works for long hours and must be low in energy consumption. One of its problems is that the transmission and reception distance is few and does not exceed a few meters. We worked on simulations based on a network consisting of ZigBee or fifth-generation (5G) and 5G with multiple-input and multiple-output (MIMO) nodes to deliver information to the center (hospital) at a 2.4 to 2.8 or 5 GHz frequency to solve this problem. Suppose the sensors are connected to the Arduino, which in turn is connected to the transmitter connection. The proposed method transmits data obtained from the sensor that touched the patient by multi-node to the hospital. The suggested method shows the best scenario to reduce energy consumption based on the number of active nodes. Based on the results obtained, we have noticed that ZigBee devices reduce energy use, perform better, and significantly extend the life of the nodes. While 5G devices increased the response speed in transferring data. In addition, MIMO antennas have the advantage of adding more stability in the connection between nodes.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i2.3219</dc:identifier><dc:identifier>10.11591/eei.v11i2.3219</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 2 (2022); 893-900</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3219/2558</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
15 sitasi
Crossref
Terindeks
lewat DOI
9 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
AL-Asadi, A. M. Q., Muttair, K. S., Wadday, A. G., & Mosleh, M. F. (2022). Wireless body-area network monitoring with ZigBee, 5G and 5G with MIMO for outdoor environments. Bulletin of Electrical Engineering and Informatics, 11(2), 893–900. https://doi.org/10.11591/eei.v11i2.3219
Salin
IEEE
A. M. Q. AL-Asadi, K. S. Muttair, A. G. Wadday, and M. F. Mosleh, “Wireless body-area network monitoring with ZigBee, 5G and 5G with MIMO for outdoor environments,” Bulletin of Electrical Engineering and Informatics, vol. 11, no. 2, pp. 893–900, 2022, doi: 10.11591/eei.v11i2.3219.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.