Akses terbuka
Jurnal
SINTA 1
Dynamic voltage restorer based on particle swarm optimization algorithm and adaptive neuro-fuzzy inference system
Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3217–3227
ISSN 2089-3191, 2302-9285
Terbit 2022-12-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This article uses a dynamic voltage restorer to tackle a wide range of power quality issues, such as voltage drooping and swelling, spikes, distortions, and so on. The proportional controller, integrated controller (PI), and adaptive neuro-fuzzy inference system (ANFIS) are proposed dynamic voltage restorer (DVR) controllers. The control strategy's goal is to employ an injection transformer to mitigate for the needed voltage and keep the load voltage fixed. The settings of the PI controller are fine-tuned using two methods: trial and error and intelligent optimum. Particle swarm optimization (PSO) is now the most effective method. In terms of settling time, overshoot, undershoot, and disturbances around the final value, the PSO-tuned PI controller outperforms the trial-and-error PI controller. The ANFIS controller is used to regulate the DVR's responsiveness through the PI-PSO controller. The PI-PSO data is used as training data by the ANFIS controller. The results show that a DVR with an ANFIS controller outperforms a PI-PSO controller in terms of overshoot, undershoot spike voltage, steady state time, and settling time. In the case of a failure voltage, the DVR with an ANFIS controller has a 27% undershoot spike voltage while the PI-PSO controller has a 30% undershoot spike voltage.
Jaringan kolaborasi para penulis
9 penulis ·
13 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Technology - Iraq Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Dynamic voltage restorer based on particle swarm optimization algorithm and adaptive neuro-fuzzy inference system</dc:title><dc:creator>Saddam Subhi Salman</dc:creator><dc:creator>Abdulrahim Thiab Humod</dc:creator><dc:creator>Fadhil A. Hasan</dc:creator><dc:subject>dynamic voltage restorer</dc:subject><dc:subject>power quality</dc:subject><dc:subject>voltage sag and swell</dc:subject><dc:subject>voltage spikes</dc:subject><dc:subject>voltage distortion</dc:subject><dc:subject>particle swarm optimization</dc:subject><dc:subject>adaptive neuro-fuzzy inference system</dc:subject><dc:subject>PI controller tuning</dc:subject><dc:subject>injection transformer</dc:subject><dc:description xml:lang="en">This article uses a dynamic voltage restorer to tackle a wide range of power quality issues, such as voltage drooping and swelling, spikes, distortions, and so on. The proportional controller, integrated controller (PI), and adaptive neuro-fuzzy inference system (ANFIS) are proposed dynamic voltage restorer (DVR) controllers. The control strategy's goal is to employ an injection transformer to mitigate for the needed voltage and keep the load voltage fixed. The settings of the PI controller are fine-tuned using two methods: trial and error and intelligent optimum. Particle swarm optimization (PSO) is now the most effective method. In terms of settling time, overshoot, undershoot, and disturbances around the final value, the PSO-tuned PI controller outperforms the trial-and-error PI controller. The ANFIS controller is used to regulate the DVR's responsiveness through the PI-PSO controller. The PI-PSO data is used as training data by the ANFIS controller. The results show that a DVR with an ANFIS controller outperforms a PI-PSO controller in terms of overshoot, undershoot spike voltage, steady state time, and settling time. In the case of a failure voltage, the DVR with an ANFIS controller has a 27% undershoot spike voltage while the PI-PSO controller has a 30% undershoot spike voltage.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4023</dc:identifier><dc:identifier>10.11591/eei.v11i6.4023</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3217-3227</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4023/2990</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
13 sitasi
Crossref
Terindeks
lewat DOI
9 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Salman, S. S., Humod, A. T., & Hasan, F. A. (2022). Dynamic voltage restorer based on particle swarm optimization algorithm and adaptive neuro-fuzzy inference system. Bulletin of Electrical Engineering and Informatics, 11(6), 3217–3227. https://doi.org/10.11591/eei.v11i6.4023
Salin
IEEE
S. S. Salman, A. T. Humod, and F. A. Hasan, “Dynamic voltage restorer based on particle swarm optimization algorithm and adaptive neuro-fuzzy inference system,” Bulletin of Electrical Engineering and Informatics, vol. 11, no. 6, pp. 3217–3227, 2022, doi: 10.11591/eei.v11i6.4023.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.