Akses terbuka
Jurnal
SINTA 1
Faults detection, location, and classification of the elements in the power system using intelligent algorithm
Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 2 (2023) · hlm. 597–607
ISSN 2089-3191, 2302-9285
Terbit 2023-04-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.
Jaringan kolaborasi para penulis
14 penulis ·
21 tautan kepenulisan bersama
· 7 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Mosul Universiti Sains Malaysia University of Technology Malaysia Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Faults detection, location, and classification of the elements in the power system using intelligent algorithm</dc:title><dc:creator>Ali Abbawi</dc:creator><dc:creator>Ibrahim Ismael Alnaib</dc:creator><dc:creator>Omar Sh. Alyozbaky</dc:creator><dc:creator>Karam Khairullah Mohammed</dc:creator><dc:subject>power system fault detection</dc:subject><dc:subject>fault location</dc:subject><dc:subject>fault classification</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>differential relay</dc:subject><dc:subject>distance relays</dc:subject><dc:subject>transformer protection</dc:subject><dc:subject>transmission line protection</dc:subject><dc:subject>zero-sequence current</dc:subject><dc:subject>Levenberg-Marquardt training</dc:subject><dc:subject>hidden layer optimization</dc:subject><dc:description xml:lang="en">This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i2.4456</dc:identifier><dc:identifier>10.11591/eei.v12i2.4456</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 2 (2023); 597-607</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4456/3123</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
13 sitasi
Crossref
Terindeks
lewat DOI
6 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Abbawi, A., Alnaib, I. I., Alyozbaky, O. S., & Mohammed, K. K. (2023). Faults detection, location, and classification of the elements in the power system using intelligent algorithm. Bulletin of Electrical Engineering and Informatics, 12(2), 597–607. https://doi.org/10.11591/eei.v12i2.4456
Salin
IEEE
A. Abbawi, I. I. Alnaib, O. S. Alyozbaky, and K. K. Mohammed, “Faults detection, location, and classification of the elements in the power system using intelligent algorithm,” Bulletin of Electrical Engineering and Informatics, vol. 12, no. 2, pp. 597–607, 2023, doi: 10.11591/eei.v12i2.4456.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.