Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Faults detection, location, and classification of the elements in the power system using intelligent algorithm

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 2 (2023) · hlm. 597–607

DOI
10.11591/eei.v12i2.4456
ISSN
2089-3191, 2302-9285
Terbit
2023-04-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 21 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Mosul
  • Universiti Sains Malaysia
  • University of Technology Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wisam NajemUniversity of Mosul1
Shaker Mahmood KhudherUniversity of Mosul1
Ibrahim IsmaeelAfiliasi tidak diketahui1
Sa’ad Ahmed Saleh Al KazzazUniversity of Mosul1
Mustafa AljammalUniversity of Mosul1
Anas MustafaUniversity of Mosul1
Hiba Nadhim A. Al-KaoazUniversity of Mosul1
Mohd Fadzil AinUniversiti Sains Malaysia1
Mohamad Kamarol Mohd JamilUniversiti Sains Malaysia1
Mazyed A. Al-TakUniversiti Sains Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Faults detection, location, and classification of the elements in the power system using intelligent algorithm</dc:title><dc:creator>Ali Abbawi</dc:creator><dc:creator>Ibrahim Ismael Alnaib</dc:creator><dc:creator>Omar Sh. Alyozbaky</dc:creator><dc:creator>Karam Khairullah Mohammed</dc:creator><dc:subject>power system fault detection</dc:subject><dc:subject>fault location</dc:subject><dc:subject>fault classification</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>differential relay</dc:subject><dc:subject>distance relays</dc:subject><dc:subject>transformer protection</dc:subject><dc:subject>transmission line protection</dc:subject><dc:subject>zero-sequence current</dc:subject><dc:subject>Levenberg-Marquardt training</dc:subject><dc:subject>hidden layer optimization</dc:subject><dc:description xml:lang="en">This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i2.4456</dc:identifier><dc:identifier>10.11591/eei.v12i2.4456</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 2 (2023); 597-607</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4456/3123</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>