With the passage of time, the importance of using renewable energy systems to overcome energy consumption and improve the quality of the grid has emerged through the use of nonlinear control techniques and reliance on advanced types of inverters such as multi-level inverters. This research is focused on comparing two grid-connected converter topologies in a photovoltaic (PV) generation system connected to a three-phase grid that serves a non-linear load. Additionally, the study explores two different control techniques applied to this converter, evaluating their effects on the total harmonic distortion coefficient. A comparison has been made between the traditional inverter and the three-level inverter type neutral point clamped (NPC) inverter, with the use of integral backstepping (IBS) technique which was also compared with the proportional integral (PI) controller. The simulation results in MATLAB/Simulink are presented illustrating the performances and the strong effectiveness of the three-level NPC inverter controlled by the proposed technique (IBS).

Kata kunci

Jaringan kolaborasi para penulis

39 penulis · 110 tautan kepenulisan bersama · 24 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Hassan II Casablanca
  • Université Moulay Ismail de Meknes
  • Institut of Research in Solar Energy and New Energies
  • Chouaib Doukkali University
  • Sidi Mohamed Ben Abdellah University
  • Université Sultan Moulay Slimane
  • Université Ibn-Tofail
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bouchaib CherradiUniversity of Hassan II Casablanca4
Abdelmounime El MagriUniversity of Hassan II Casablanca4
Soufiane HamidaUniversity of Hassan II Casablanca3
Hamid BouyghfUniversity of Hassan II Casablanca2
Oussama El GannourUniversity of Hassan II Casablanca2
Adil MansouriUniversity of Hassan II Casablanca2
Khalifa MansouriUniversity of Hassan II Casablanca2
Ilham TyassUniversity of Hassan II Casablanca2
Bachir BenhalaUniversité Moulay Ismail de Meknes1
Hassan OuajjiUniversity of Hassan II Casablanca1
Issa SabiriUniversity of Hassan II Casablanca1
Asmae OuhmidaUniversity of Hassan II Casablanca1
Sara SandabadUniversity of Hassan II Casablanca1
Nouhaila BelmajdoubUniversity of Hassan II Casablanca1
Soukaina BoudoudouhInstitut of Research in Solar Energy and New Energies1
Mohamed Amine OuassilUniversity of Hassan II Casablanca1
Mohammed JebbariUniversity of Hassan II Casablanca1
Rabia RachidiChouaib Doukkali University1
Mouaad ErramiUniversity of Hassan II Casablanca1
Abdeljalil El HadiriUniversity of Hassan II Casablanca1
Lhoussain BahattiUniversity of Hassan II Casablanca1
Doha El HafianeUniversity of Hassan II Casablanca1
Ilyass El MyasseUniversity of Hassan II Casablanca1
Younes El KhlifiUniversity of Hassan II Casablanca1
Mohamed Said AdouairiSidi Mohamed Ben Abdellah University1
Omar BouattaneUniversity of Hassan II Casablanca1
Mohamed YoussfiUniversity of Hassan II Casablanca1
Meryem HamidiUniversity of Hassan II Casablanca1
Abdelouahed BellatAfiliasi tidak diketahui1
Mohamed RafikUniversity of Hassan II Casablanca1
Bellat AbdelouahedAfiliasi tidak diketahui1
Tajeddine KhaliliUniversité Sultan Moulay Slimane1
Yasser LamalemUniversité Ibn-Tofail1
Mohamed Amine MahjoubiUniversity of Hassan II Casablanca1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Nonlinear control of three level NPC inverter used in PV/grid system: comparison of topologies and control methods</dc:title><dc:creator>Youness Atifi</dc:creator><dc:creator>Abdelhadi Raihani</dc:creator><dc:creator>Mohammed Kissaoui</dc:creator><dc:creator>Rachid Lajouad</dc:creator><dc:creator>Khalid Errakkas</dc:creator><dc:subject>three-level inverter</dc:subject><dc:subject>neutral point clamped inverter</dc:subject><dc:subject>photovoltaic grid connection</dc:subject><dc:subject>nonlinear control</dc:subject><dc:subject>integral backstepping control</dc:subject><dc:subject>PI controller</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>three-phase grid</dc:subject><dc:description xml:lang="en">With the passage of time, the importance of using renewable energy systems to overcome energy consumption and improve the quality of the grid has emerged through the use of nonlinear control techniques and reliance on advanced types of inverters such as multi-level inverters. This research is focused on comparing two grid-connected converter topologies in a photovoltaic (PV) generation system connected to a three-phase grid that serves a non-linear load. Additionally, the study explores two different control techniques applied to this converter, evaluating their effects on the total harmonic distortion coefficient. A comparison has been made between the traditional inverter and the three-level inverter type neutral point clamped (NPC) inverter, with the use of integral backstepping (IBS) technique which was also compared with the proportional integral (PI) controller. The simulation results in MATLAB/Simulink are presented illustrating the performances and the strong effectiveness of the three-level NPC inverter controlled by the proposed technique (IBS).</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i3.7122</dc:identifier><dc:identifier>10.11591/eei.v13i3.7122</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 3 (2024); 2165-2174</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7122/3754</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>