Akses terbuka
Jurnal
SINTA 1
Packet loss compensation over wireless networked using an optimized FOPI-FOPD controller for nonlinear system
Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3176–3187
ISSN 2089-3191, 2302-9285
Terbit 2022-12-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
Wireless networked control systems (WNCS) consist of an actuator, sensor, and controller communicating over wireless networks in place of traditional point-to-point wired connection. Due to their main advantages, a decrease in maintenance costs, more flexibility, and safety could be achieved. As a result, it attracted a great deal of interest, but packet losses and time delays in the wireless network through transmitting and receiving the data are considered very challenging issues, which impair the output accuracy of the WNCS and can affect the entire system stability. In this study, integer-order proportional integral-proportional derivative (PI-PD) and fractional-order PI-PD (FOPI-FOPD) controllers are proposed to reduce the effect of expected packet loss in a WNCS to improve system performance. At high packet loss percent, the PI controller is introduced to act as a compensator in the feed-forward loop to keep the system stable. MATLAB/Simulink and Truetime simulator are used to simulate the WNCS. The rotary inverted pendulum (RIP) is utilized as the object of the controllers. Grey wolf optimization (GWO) algorithm is used to find the optimal controllers and compensator parameters. The simulation results showed that the FOPI-FOPD is superior to PI-PD in the packet loss compensation.
Jaringan kolaborasi para penulis
8 penulis ·
12 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Tikrit Middle Technical University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Packet loss compensation over wireless networked using an optimized FOPI-FOPD controller for nonlinear system</dc:title><dc:creator>Muhannad Ali Hasan</dc:creator><dc:creator>Ahmed A. Oglah</dc:creator><dc:creator>Mehdi J. Marie</dc:creator><dc:subject>wireless networked control systems</dc:subject><dc:subject>packet loss compensation</dc:subject><dc:subject>feedforward compensator</dc:subject><dc:subject>rotary inverted pendulum</dc:subject><dc:subject>grey wolf optimizer</dc:subject><dc:subject>controller tuning</dc:subject><dc:subject>nonlinear systems</dc:subject><dc:subject>time delay</dc:subject><dc:description xml:lang="en">Wireless networked control systems (WNCS) consist of an actuator, sensor, and controller communicating over wireless networks in place of traditional point-to-point wired connection. Due to their main advantages, a decrease in maintenance costs, more flexibility, and safety could be achieved. As a result, it attracted a great deal of interest, but packet losses and time delays in the wireless network through transmitting and receiving the data are considered very challenging issues, which impair the output accuracy of the WNCS and can affect the entire system stability. In this study, integer-order proportional integral-proportional derivative (PI-PD) and fractional-order PI-PD (FOPI-FOPD) controllers are proposed to reduce the effect of expected packet loss in a WNCS to improve system performance. At high packet loss percent, the PI controller is introduced to act as a compensator in the feed-forward loop to keep the system stable. MATLAB/Simulink and Truetime simulator are used to simulate the WNCS. The rotary inverted pendulum (RIP) is utilized as the object of the controllers. Grey wolf optimization (GWO) algorithm is used to find the optimal controllers and compensator parameters. The simulation results showed that the FOPI-FOPD is superior to PI-PD in the packet loss compensation.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4345</dc:identifier><dc:identifier>10.11591/eei.v11i6.4345</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3176-3187</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4345/3037</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
11 sitasi
Crossref
Terindeks
lewat DOI
4 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Hasan, M. A., Oglah, A. A., & Marie, M. J. (2022). Packet loss compensation over wireless networked using an optimized FOPI-FOPD controller for nonlinear system. Bulletin of Electrical Engineering and Informatics, 11(6), 3176–3187. https://doi.org/10.11591/eei.v11i6.4345
Salin
IEEE
M. A. Hasan, A. A. Oglah, and M. J. Marie, “Packet loss compensation over wireless networked using an optimized FOPI-FOPD controller for nonlinear system,” Bulletin of Electrical Engineering and Informatics, vol. 11, no. 6, pp. 3176–3187, 2022, doi: 10.11591/eei.v11i6.4345.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.