Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Pre-trained Bi-LSTM model for automated classification of ventricular arrhythmias using 1-D and 2-D ECG

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 4 (2024) · hlm. 2485–2495

DOI
10.11591/eei.v13i4.6705
ISSN
2089-3191, 2302-9285
Terbit
2024-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Number of cardiac conditions have been associated with abnormal heartbeat (arrhythmia) such as ventricular fibrillation (Vfib), ventricular flutter (Vfl), and ventricular tachycardia (Vta). This is a difficult and essential job for timely clinical assessment and identification of these potentially life-threatening heart arrhythmias. With the aid of a one-dimensional electrocardiogram (ECG) signal and its associated two-dimensional image, the suggested method provides a strategy for the detection of time-frequency interpretation (Vfib, Vfl, and Vta). A four-stage cascaded Savitzky-Golay (SG) filter is used after a 2-stage median filter to preprocess the ECG signal. This technique employs z-score normalisation after brief (2 sec) ECG readings. The classification of these ECG segments (1-D) and associated time-frequency representation pictures (2-D) was explored separately using a bi-directional long short-term memory-based network. Eight distinct categorization scenarios were examined, and then an average accuracy of 99.67% for 1-D ECG and 99.87% for 2-D ECG signal was attained.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • VIT-AP University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Pre-trained Bi-LSTM model for automated classification of ventricular arrhythmias using 1-D and 2-D ECG</dc:title><dc:creator>M. Krishna Chaitanya</dc:creator><dc:creator>Lakhan Dev Sharma</dc:creator><dc:subject>ventricular fibrillation</dc:subject><dc:subject>ventricular flutter</dc:subject><dc:subject>ventricular tachycardia</dc:subject><dc:subject>ECG signal preprocessing</dc:subject><dc:subject>Savitzky-Golay filter</dc:subject><dc:subject>median filter</dc:subject><dc:subject>time-frequency representation</dc:subject><dc:subject>bidirectional LSTM</dc:subject><dc:subject>pre-trained deep learning models</dc:subject><dc:description xml:lang="en">Number of cardiac conditions have been associated with abnormal heartbeat (arrhythmia) such as ventricular fibrillation (Vfib), ventricular flutter (Vfl), and ventricular tachycardia (Vta). This is a difficult and essential job for timely clinical assessment and identification of these potentially life-threatening heart arrhythmias. With the aid of a one-dimensional electrocardiogram (ECG) signal and its associated two-dimensional image, the suggested method provides a strategy for the detection of time-frequency interpretation (Vfib, Vfl, and Vta). A four-stage cascaded Savitzky-Golay (SG) filter is used after a 2-stage median filter to preprocess the ECG signal. This technique employs z-score normalisation after brief (2 sec) ECG readings. The classification of these ECG segments (1-D) and associated time-frequency representation pictures (2-D) was explored separately using a bi-directional long short-term memory-based network. Eight distinct categorization scenarios were examined, and then an average accuracy of 99.67% for 1-D ECG and 99.87% for 2-D ECG signal was attained.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i4.6705</dc:identifier><dc:identifier>10.11591/eei.v13i4.6705</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 4 (2024); 2485-2495</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6705/3794</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>