Akses terbuka
Jurnal
SINTA 1
Glaucoma classification using a polynomial-driven deep learning approach
Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 4 (2023) · hlm. 2245–2261
ISSN 2089-3191, 2302-9285
Terbit 2023-08-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
In this paper, a deep learning-based multi-stage polynomial driven glaucoma classification-net (PDGC-Net) has been proposed for glaucoma identification through retinal images. The proposed approach begins with retinal image pu[1]rification by noise estimation and reduction. Noise has been estimated using a polynomial coefficient-based approach. Images are classified using PDGC-Net, whose polynomial indeterminate representative blocks are designed using new convolutional neural networks (CNN) architectures. The performance of PDGC[1]Net has been observed on the ACRIMA, ORIGA, and retinal image database for optic nerve evaluation (RIM-ONE) datasets. The experimentation is carried out on noisy and denoised images separately, and PDGC-Net has achieved 96% to 98% and 98% to 100% accuracy ranges, respectively. The model’s elasticity is tested with various stages of PDGC-Net. The quantitative PDGC-Net perfor[1]mance analysis is done with state-of-the-art CNN models. The proposed model’s performance has been proven and could be an effective aid to ophthalmologists for glaucoma screening (GS).
Jaringan kolaborasi para penulis
5 penulis ·
5 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Siddhartha Academy of Higher Education VIT-AP University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Glaucoma classification using a polynomial-driven deep learning approach</dc:title><dc:creator>Krishna Santosh Naidana</dc:creator><dc:creator>Soubhagya Sankar Barpanda</dc:creator><dc:subject>glaucoma classification</dc:subject><dc:subject>fundus images</dc:subject><dc:subject>noise estimation</dc:subject><dc:subject>convolutional neural networks</dc:subject><dc:subject>glaucoma screening</dc:subject><dc:subject>multi-stage neural network</dc:subject><dc:description xml:lang="en">In this paper, a deep learning-based multi-stage polynomial driven glaucoma classification-net (PDGC-Net) has been proposed for glaucoma identification through retinal images. The proposed approach begins with retinal image pu[1]rification by noise estimation and reduction. Noise has been estimated using a polynomial coefficient-based approach. Images are classified using PDGC-Net, whose polynomial indeterminate representative blocks are designed using new convolutional neural networks (CNN) architectures. The performance of PDGC[1]Net has been observed on the ACRIMA, ORIGA, and retinal image database for optic nerve evaluation (RIM-ONE) datasets. The experimentation is carried out on noisy and denoised images separately, and PDGC-Net has achieved 96% to 98% and 98% to 100% accuracy ranges, respectively. The model’s elasticity is tested with various stages of PDGC-Net. The quantitative PDGC-Net perfor[1]mance analysis is done with state-of-the-art CNN models. The proposed model’s performance has been proven and could be an effective aid to ophthalmologists for glaucoma screening (GS).</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.11591/eei.v12i4.4670</dc:identifier><dc:identifier>10.11591/eei.v12i4.4670</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 4 (2023); 2245-2261</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
10 sitasi
Crossref
Terindeks
lewat DOI
8 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Naidana, K. S., & Barpanda, S. S. (2023). Glaucoma classification using a polynomial-driven deep learning approach. Bulletin of Electrical Engineering and Informatics, 12(4), 2245–2261. https://doi.org/10.11591/eei.v12i4.4670
Salin
IEEE
K. S. Naidana and S. S. Barpanda, “Glaucoma classification using a polynomial-driven deep learning approach,” Bulletin of Electrical Engineering and Informatics, vol. 12, no. 4, pp. 2245–2261, 2023, doi: 10.11591/eei.v12i4.4670.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.