Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Power system contingency classification using machine learning technique

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 6 (2022) · hlm. 3091–3098

DOI
10.11591/eei.v11i6.4031
ISSN
2089-3191, 2302-9285
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

One of the most effective ways for estimating the impact and severity of line failures on the static security of the power system is contingency analysis. The contingency categorization approach uses the overall performance index to measure the system's severity (OPI). The newton raphson (NR) load flow technique is used to extract network variables in a contingency situation for each transmission line failure. Static security is categorised into five categories in this paper: secure (S), critically secure (CS), insecure (IS), highly insecure (HIS), and most insecure (MIS). The K closest neighbor machine learning strategy is presented to categorize these patterns. The proposed machine learning classifiers are trained on the IEEE 30 bus system before being evaluated on the IEEE 14, IEEE 57, and IEEE 118 bus systems. The suggested k-nearest neighbor (KNN) classifier increases the accuracy of power system security assessments categorization. A fuzzy logic approach was also investigated and implemented for the IEEE 14 bus test system to forecast the aforementioned five classifications.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 26 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Osmania University
  • Rajiv Gandhi University of Knowledge Technologies
  • Koneru Lakshmaiah Education Foundation
  • Chaitanya Bharathi Institute of Technology
  • Chaitanya
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bhukya BhavsinghRajiv Gandhi University of Knowledge Technologies3
S. V. N. L. LalithaKoneru Lakshmaiah Education Foundation3
Ravi PonnalaKoneru Lakshmaiah Education Foundation3
Suresh Babu GotluruChaitanya Bharathi Institute of Technology2
Ravikumar BhukyaOsmania University2
Ravi Kumar BhukyaAfiliasi tidak diketahui1
Vaani DongariRajiv Gandhi University of Knowledge Technologies1
G. Suresh BabuChaitanya1
B. Mohan RaoOsmania University1
Mohammad Haseeb KhanOsmania University1
G. Prem Kumar ReddyAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Power system contingency classification using machine learning technique</dc:title><dc:creator>Sandhya Rani Gongada</dc:creator><dc:creator>Muktevi Chakravarthy</dc:creator><dc:creator>Bhukya Mangu</dc:creator><dc:subject>static security assessment</dc:subject><dc:subject>transmission line failures</dc:subject><dc:subject>k-nearest neighbors</dc:subject><dc:subject>fuzzy logic</dc:subject><dc:subject>Newton-Raphson load flow</dc:subject><dc:subject>IEEE bus test systems</dc:subject><dc:subject>power system security</dc:subject><dc:description xml:lang="en">One of the most effective ways for estimating the impact and severity of line failures on the static security of the power system is contingency analysis. The contingency categorization approach uses the overall performance index to measure the system's severity (OPI). The newton raphson (NR) load flow technique is used to extract network variables in a contingency situation for each transmission line failure. Static security is categorised into five categories in this paper: secure (S), critically secure (CS), insecure (IS), highly insecure (HIS), and most insecure (MIS). The K closest neighbor machine learning strategy is presented to categorize these patterns. The proposed machine learning classifiers are trained on the IEEE 30 bus system before being evaluated on the IEEE 14, IEEE 57, and IEEE 118 bus systems. The suggested k-nearest neighbor (KNN) classifier increases the accuracy of power system security assessments categorization. A fuzzy logic approach was also investigated and implemented for the IEEE 14 bus test system to forecast the aforementioned five classifications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i6.4031</dc:identifier><dc:identifier>10.11591/eei.v11i6.4031</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 6 (2022); 3091-3098</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/4031/2978</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>