This paper presents a new time-domain multi-objective function approach for solving load frequency control issue in an interconnected power system. The performance of interconnected power system in each area is validated for overshoot and settling time values of frequency change and tie-line power exchange. An objective function is created with the goal of enhancing proportional integral derivative (PID) controller settings by reducing overshoot and achieving faster time-domain settling times. The efficiency of the proposed time-domain multi-objective function is evaluated in a two-area thermal power plant using a nature-inspired cuckoo search optimization (CSA) technique. By comparing the time-domain simulation results of the test system with the existing integral error-based objective functions IAE, ISE, ITAE, and ITSE, the proposed objective function is validated. Further, a sensitivity analysis were carried out to analyze the robustness of the proposed multi-objective function under various uncertain conditions.
Jaringan kolaborasi para penulis
11 penulis ·
26 tautan kepenulisan bersama
· 19 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
MVJ College of Engineering New Horizon College of Engineering KIIT University JSPM University Nitte Meenakshi Institute of Technology Vellore Institute of Technology University Sri Ramakrishna Engineering College Organisasi lain Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Load frequency control of interconnected power system using cuckoo search algorithm</dc:title><dc:creator>Soumya Mishra</dc:creator><dc:creator>Pujari Harish Kumar</dc:creator><dc:creator>Rajarajan Ramasamy</dc:creator><dc:creator>Renjini E Nambiar</dc:creator><dc:creator>Praveena Puvvada</dc:creator><dc:subject>load frequency control</dc:subject><dc:subject>interconnected power systems</dc:subject><dc:subject>cuckoo search algorithm</dc:subject><dc:subject>PID controller tuning</dc:subject><dc:subject>time-domain performance</dc:subject><dc:subject>overshoot and settling time</dc:subject><dc:subject>tie-line power exchange</dc:subject><dc:subject>sensitivity analysis</dc:subject><dc:subject>robustness under uncertainty</dc:subject><dc:description xml:lang="en">This paper presents a new time-domain multi-objective function approach for solving load frequency control issue in an interconnected power system. The performance of interconnected power system in each area is validated for overshoot and settling time values of frequency change and tie-line power exchange. An objective function is created with the goal of enhancing proportional integral derivative (PID) controller settings by reducing overshoot and achieving faster time-domain settling times. The efficiency of the proposed time-domain multi-objective function is evaluated in a two-area thermal power plant using a nature-inspired cuckoo search optimization (CSA) technique. By comparing the time-domain simulation results of the test system with the existing integral error-based objective functions IAE, ISE, ITAE, and ITSE, the proposed objective function is validated. Further, a sensitivity analysis were carried out to analyze the robustness of the proposed multi-objective function under various uncertain conditions.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i3.6714</dc:identifier><dc:identifier>10.11591/eei.v13i3.6714</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 3 (2024); 1465-1474</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6714/3677</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
8 sitasi
Crossref
Terindeks
lewat DOI
5 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Mishra, S., Kumar, P. H., Ramasamy, R., Nambiar, R. E., & Puvvada, P. (2024). Load frequency control of interconnected power system using cuckoo search algorithm. Bulletin of Electrical Engineering and Informatics, 13(3), 1465–1474. https://doi.org/10.11591/eei.v13i3.6714
Salin
IEEE
S. Mishra, P. H. Kumar, R. Ramasamy, R. E. Nambiar, and P. Puvvada, “Load frequency control of interconnected power system using cuckoo search algorithm,” Bulletin of Electrical Engineering and Informatics, vol. 13, no. 3, pp. 1465–1474, 2024, doi: 10.11591/eei.v13i3.6714.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.