Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Load frequency control of interconnected power system using cuckoo search algorithm

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 3 (2024) · hlm. 1465–1474

DOI
10.11591/eei.v13i3.6714
ISSN
2089-3191, 2302-9285
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper presents a new time-domain multi-objective function approach for solving load frequency control issue in an interconnected power system. The performance of interconnected power system in each area is validated for overshoot and settling time values of frequency change and tie-line power exchange. An objective function is created with the goal of enhancing proportional integral derivative (PID) controller settings by reducing overshoot and achieving faster time-domain settling times. The efficiency of the proposed time-domain multi-objective function is evaluated in a two-area thermal power plant using a nature-inspired cuckoo search optimization (CSA) technique. By comparing the time-domain simulation results of the test system with the existing integral error-based objective functions IAE, ISE, ITAE, and ITSE, the proposed objective function is validated. Further, a sensitivity analysis were carried out to analyze the robustness of the proposed multi-objective function under various uncertain conditions.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 26 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • MVJ College of Engineering
  • New Horizon College of Engineering
  • KIIT University
  • JSPM University
  • Nitte Meenakshi Institute of Technology
  • Vellore Institute of Technology University
  • Sri Ramakrishna Engineering College
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
R. MageshvaranVellore Institute of Technology University1
Arangarajan VinayagamNew Horizon College of Engineering1
Raman MohandasNew Horizon College of Engineering1
Chindamani MeyyappanSri Ramakrishna Engineering College1
Bhadravathi Gavirangapa SujathaAfiliasi tidak diketahui1
Arivoli SundaramurthyPSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Load frequency control of interconnected power system using cuckoo search algorithm</dc:title><dc:creator>Soumya Mishra</dc:creator><dc:creator>Pujari Harish Kumar</dc:creator><dc:creator>Rajarajan Ramasamy</dc:creator><dc:creator>Renjini E Nambiar</dc:creator><dc:creator>Praveena Puvvada</dc:creator><dc:subject>load frequency control</dc:subject><dc:subject>interconnected power systems</dc:subject><dc:subject>cuckoo search algorithm</dc:subject><dc:subject>PID controller tuning</dc:subject><dc:subject>time-domain performance</dc:subject><dc:subject>overshoot and settling time</dc:subject><dc:subject>tie-line power exchange</dc:subject><dc:subject>sensitivity analysis</dc:subject><dc:subject>robustness under uncertainty</dc:subject><dc:description xml:lang="en">This paper presents a new time-domain multi-objective function approach for solving load frequency control issue in an interconnected power system. The performance of interconnected power system in each area is validated for overshoot and settling time values of frequency change and tie-line power exchange. An objective function is created with the goal of enhancing proportional integral derivative (PID) controller settings by reducing overshoot and achieving faster time-domain settling times. The efficiency of the proposed time-domain multi-objective function is evaluated in a two-area thermal power plant using a nature-inspired cuckoo search optimization (CSA) technique. By comparing the time-domain simulation results of the test system with the existing integral error-based objective functions IAE, ISE, ITAE, and ITSE, the proposed objective function is validated. Further, a sensitivity analysis were carried out to analyze the robustness of the proposed multi-objective function under various uncertain conditions.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i3.6714</dc:identifier><dc:identifier>10.11591/eei.v13i3.6714</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 3 (2024); 1465-1474</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/6714/3677</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>