Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Hand motion pattern recognition analysis of forearm muscle using MMG signals

Bulletin of Electrical Engineering and Informatics · Vol. 8 No. 2 (2019) · hlm. 533–540

DOI
10.11591/eei.v8i2.1415
ISSN
2089-3191, 2302-9285
Terbit
2019-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Surface Mechanomyography (MMG) is the recording of mechanical activity of muscle tissue. MMG measures the mechanical signal (vibration of muscle) that generated from the muscles during contraction or relaxation action. It is widely used in various fields such as medical diagnosis, rehabilitation purpose and engineering applications. The main purpose of this research is to identify the hand gesture movement via VMG sensor (TSD250A) and classify them using Linear Discriminant Analysis (LDA). There are four channels MMG signal placed into adjacent muscles which PL-FCU and ED-ECU. The features used to feed the classifier to determine accuracy are mean absolute value, standard deviation, variance and root mean square. Most of subjects gave similar range of MMG signal of extraction values because of the adjacent muscle. The average accuracy of LDA is approximately 87.50% for the eight subjects. The finding of the result shows, MMG signal of adjacent muscle can affect the classification accuracy of the classifier.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Perlis
  • Universiti Teknikal Malaysia Melaka
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed Saeed Moqbel AbdullahUniversiti Malaysia Perlis1
N. S. KhalidUniversiti Malaysia Perlis1
Aimi Salihah Abdul NasirUniversiti Malaysia Perlis1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Hand motion pattern recognition analysis of forearm muscle using MMG signals</dc:title><dc:creator>M. R. Mohamad Ismail</dc:creator><dc:creator>Chee Kiang Lam</dc:creator><dc:creator>Kenneth Sundaraj</dc:creator><dc:creator>Mohd Hafiz Fazalul Rahiman</dc:creator><dc:subject>hand gesture recognition</dc:subject><dc:subject>forearm muscles</dc:subject><dc:subject>linear discriminant analysis</dc:subject><dc:subject>feature extraction</dc:subject><dc:subject>classification accuracy</dc:subject><dc:description xml:lang="en">Surface Mechanomyography (MMG) is the recording of mechanical activity of muscle tissue. MMG measures the mechanical signal (vibration of muscle) that generated from the muscles during contraction or relaxation action. It is widely used in various fields such as medical diagnosis, rehabilitation purpose and engineering applications. The main purpose of this research is to identify the hand gesture movement via VMG sensor (TSD250A) and classify them using Linear Discriminant Analysis (LDA). There are four channels MMG signal placed into adjacent muscles which PL-FCU and ED-ECU. The features used to feed the classifier to determine accuracy are mean absolute value, standard deviation, variance and root mean square. Most of subjects gave similar range of MMG signal of extraction values because of the adjacent muscle. The average accuracy of LDA is approximately 87.50% for the eight subjects. The finding of the result shows, MMG signal of adjacent muscle can affect the classification accuracy of the classifier.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v8i2.1415</dc:identifier><dc:identifier>10.11591/eei.v8i2.1415</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 8 No 2 (2019); 533-540</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1415/1184</dc:relation></oai_dc:dc>