Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design and analysis of current mirror OTA in 45 nm and 90 nm CMOS technology for bio-medical application

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 1 (2020) · hlm. 221–228

DOI
10.11591/eei.v9i1.1860
ISSN
2089-3191, 2302-9285
Terbit
2020-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

This paper proposed a design and performance analysis of current mirror operational transconductance amplifier (OTA) in 45 nm and 90 nm complementary metal oxide semiconductor (CMOS) technology for bio-medical application. Both OTAs were designed and simulated using Synopsys tools and the simulation results were analysed thoroughly. The OTAs were designed to be implemented in bio-potential signals detection system where the input signals were amplified and filtered according to the specifications. From the comparative analysis of both OTAs, the 45 nm OTA managed to produce open loop gain of 45 dB, with common mode rejection ratio (CMRR) of 93.2 dB. The 45 nm OTA produced only 1.113 μV√Hz of input referred noise at 1 Hz. The 45 nm OTA also consumed only 28.21 nW of power from ± 0.5 V supply. The low-power consumption aspect displayed by 45 nm OTA made it suitable to be implemented in bio-medical application such as bio-potential signals detection system where it can be used to amplify and filter the electrocardiogram (ECG) signals.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Universiti Teknologi MARA
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nordiana Binti MukaharUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design and analysis of current mirror OTA in 45 nm and 90 nm CMOS technology for bio-medical application</dc:title><dc:creator>Wan Mohammad Ehsan Aiman bin Wan Jusoh</dc:creator><dc:creator>Siti Hawa Ruslan</dc:creator><dc:subject>current mirror</dc:subject><dc:subject>operational transconductance amplifier</dc:subject><dc:subject>OTA</dc:subject><dc:subject>45 nm CMOS</dc:subject><dc:subject>90 nm CMOS</dc:subject><dc:subject>low-power analog circuits</dc:subject><dc:subject>common-mode rejection ratio</dc:subject><dc:subject>input-referred noise</dc:subject><dc:subject>open-loop gain</dc:subject><dc:description xml:lang="en">This paper proposed a design and performance analysis of current mirror operational transconductance amplifier (OTA) in 45 nm and 90 nm complementary metal oxide semiconductor (CMOS) technology for bio-medical application. Both OTAs were designed and simulated using Synopsys tools and the simulation results were analysed thoroughly. The OTAs were designed to be implemented in bio-potential signals detection system where the input signals were amplified and filtered according to the specifications. From the comparative analysis of both OTAs, the 45 nm OTA managed to produce open loop gain of 45 dB, with common mode rejection ratio (CMRR) of 93.2 dB. The 45 nm OTA produced only 1.113 μV√Hz of input referred noise at 1 Hz. The 45 nm OTA also consumed only 28.21 nW of power from ± 0.5 V supply. The low-power consumption aspect displayed by 45 nm OTA made it suitable to be implemented in bio-medical application such as bio-potential signals detection system where it can be used to amplify and filter the electrocardiogram (ECG) signals.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i1.1860</dc:identifier><dc:identifier>10.11591/eei.v9i1.1860</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 1 (2020); 221-228</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1860/1274</dc:relation></oai_dc:dc>