Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Diagnosis of arrhythmia based on ECG analysis using CNN

Bulletin of Electrical Engineering and Informatics · Vol. 9 No. 3 (2020) · hlm. 988–995

DOI
10.11591/eei.v9i3.2172
ISSN
2089-3191, 2302-9285
Terbit
2020-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en

Abstrak

Arrhythmia is the prime indicator of serious heart issues, and, hence, it is essential to be detected properly for early phase treatment. This article presents an approach for the diagnosis of cardiac disorders via the recognition of 17 types of arrhythmia. The proposed approach includes building a convolution neural network (2D-CNN) which is trained by using images of Electrocardiograph (ECG) signals collected from the MIH-BIH database. The ECGs are first converted into images. This step serves twofold: first, CNN is best suited for classifying image data and thus reduces preprocessing, and second, most ECG recordings are still being produced on thermal paper which can then be captured as image. Next, 2D-CNN is trained and validated. Test results show that the proposed method achieves classification accuracy of 96.67% and error of 0.004%. in addition to the superior accuracy achieved by this method compared to the previous literature, this approach enjoys reduced processing time and complexity apart from the training phase, also by dealing with images this method offers high degree of versatility and can be integrated as utility within other applications or wearables.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Wasit
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Diagnosis of arrhythmia based on ECG analysis using CNN</dc:title><dc:creator>Muayed S. Al‐Huseiny</dc:creator><dc:creator>Noor Abbas</dc:creator><dc:creator>Ahmed Sattar Sajit</dc:creator><dc:subject>arrhythmia detection</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>convolutional neural networks</dc:subject><dc:subject>ECG image classification</dc:subject><dc:subject>arrhythmia classification</dc:subject><dc:subject>wearable health monitoring</dc:subject><dc:description xml:lang="en">Arrhythmia is the prime indicator of serious heart issues, and, hence, it is essential to be detected properly for early phase treatment. This article presents an approach for the diagnosis of cardiac disorders via the recognition of 17 types of arrhythmia. The proposed approach includes building a convolution neural network (2D-CNN) which is trained by using images of Electrocardiograph (ECG) signals collected from the MIH-BIH database. The ECGs are first converted into images. This step serves twofold: first, CNN is best suited for classifying image data and thus reduces preprocessing, and second, most ECG recordings are still being produced on thermal paper which can then be captured as image. Next, 2D-CNN is trained and validated. Test results show that the proposed method achieves classification accuracy of 96.67% and error of 0.004%. in addition to the superior accuracy achieved by this method compared to the previous literature, this approach enjoys reduced processing time and complexity apart from the training phase, also by dealing with images this method offers high degree of versatility and can be integrated as utility within other applications or wearables.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v9i3.2172</dc:identifier><dc:identifier>10.11591/eei.v9i3.2172</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 9 No 3 (2020); 988-995</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/2172/1443</dc:relation></oai_dc:dc>