The existence of nonlinear loads produces high distortion and low power factor in the power system that leads to get poor power quality. Resonance problem is occurred due to the power system inductances and the compensation capacitors which increases the harmonic distortion. Therefore, it is necessary to prevent the action of resonance even if conventional or modern methods are built to improve the power system quality. In this paper, active static compensation circuit is proposed and designed to have the features of improving power factor, reducing THD, and eliminating the harmonics resonance effect at the same time with different linear and nonlinear load conditions. These features have been performed based on a modified pulse width modulation technique to drive and control the proposed circuit. The originality designed point of this technique is to have ability to operate the active static compensation circuit as harmonics injector, power factor corrector and resonance eliminator at the same time. Simulation model results illustrate that the proposed circuit is effective for both steady-state and transient operations conditions. The THD of the supply voltage and current at firing angle (α=300) is reduced by 99% and 98.8% respectively. While the power factor is improved to stay around unity.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 25 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • University of Mosul
  • Ninevah University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ali Riyadh AliUniversity of Mosul2
Abdulghani Abdulrazzaq AbdulghafoorUniversity of Mosul2
Ahmed Jadaan AliNorthern Technical University2
Harith Al-BadraniNinevah University2
Laith A. KhalafNorthern Technical University1
Nashwan Saleh SultanNorthern Technical University1
Zozan Saadallah HussainNorthern Technical University1
Ahmed Ateya AlluNorthern Technical University1
Taha Ahmed HusseinNorthern Technical University1
Abdallah Mohamed AbdullahNorthern Technical University1
Mahmood Taha AlkhayyatNorthern Technical University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Harmonics resonance elimination technique using active static compensation circuit</dc:title><dc:creator>Rakan Khalil Antar</dc:creator><dc:creator>Mohammed Y. Suliman</dc:creator><dc:creator>Asef A. Saleh</dc:creator><dc:subject>harmonic distortion</dc:subject><dc:subject>power factor correction</dc:subject><dc:subject>total harmonic distortion reduction</dc:subject><dc:subject>nonlinear loads</dc:subject><dc:subject>harmonic injection</dc:subject><dc:subject>power quality</dc:subject><dc:description xml:lang="en">The existence of nonlinear loads produces high distortion and low power factor in the power system that leads to get poor power quality. Resonance problem is occurred due to the power system inductances and the compensation capacitors which increases the harmonic distortion. Therefore, it is necessary to prevent the action of resonance even if conventional or modern methods are built to improve the power system quality. In this paper, active static compensation circuit is proposed and designed to have the features of improving power factor, reducing THD, and eliminating the harmonics resonance effect at the same time with different linear and nonlinear load conditions. These features have been performed based on a modified pulse width modulation technique to drive and control the proposed circuit. The originality designed point of this technique is to have ability to operate the active static compensation circuit as harmonics injector, power factor corrector and resonance eliminator at the same time. Simulation model results illustrate that the proposed circuit is effective for both steady-state and transient operations conditions. The THD of the supply voltage and current at firing angle (α=300) is reduced by 99% and 98.8% respectively. While the power factor is improved to stay around unity.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2021-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v10i5.3148</dc:identifier><dc:identifier>10.11591/eei.v10i5.3148</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 10 No 5 (2021); 2405-2413</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3148/2309</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>