Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative characterization of microstrip patch antenna array with defected ground structure for biomedical application

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 1 (2022) · hlm. 346–353

DOI
10.11591/eei.v11i1.3459
ISSN
2089-3191, 2302-9285
Terbit
2022-02-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

In this paper, microstrip dual band antenna array with defected ground structure has been proposed for low frequency wearable on-body applications. The array has been simulated with Cotton, Polyimide, Polyester and Teflon (PTFE) flexible materials which are mostly used for biomedical applications. The performance of 2x2 trapezoidal patch array with partial ground, thin slot defection at center has been studied in terms of return loss, VSWR, power handling capability, radiation pattern and surface current distribution. All substrates exhibits acceptable fractional bandwidth below -10 dB and Cotton proves its superiority than other substrates with -20 dB and -48 dB return loss with 16.12% and 7.73% bandwidth at 1.24 GHz and 1.94 GHz respectively. The proper matching of array has been proved with VSWR value below 1.3 for all substrates. The observation of input port impedance shows that, Cotton array has good impedance matching nearly to 50 Ω and PTFE array has 100 Ω poor impedance matching. The proposed four flexible array exhibit omnidirectional pattern in H plane with 1.43 dBi gain and bidirectional pattern in E plane with 1.4 dBi gain which are support for ideal fitness of proposed flexible material array for medical applications.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SRM University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparative characterization of microstrip patch antenna array with defected ground structure for biomedical application</dc:title><dc:creator>Suganthi Santhanam</dc:creator><dc:creator>Thiruvalar Selvan Palavesam</dc:creator><dc:subject>microstrip patch antenna array</dc:subject><dc:subject>defected ground structure</dc:subject><dc:subject>dual-band antenna</dc:subject><dc:subject>wearable antennas</dc:subject><dc:subject>on-body antenna</dc:subject><dc:subject>flexible substrates</dc:subject><dc:subject>cotton substrate</dc:subject><dc:subject>polyimide</dc:subject><dc:subject>polyesters</dc:subject><dc:subject>polytetrafluoroethylene</dc:subject><dc:subject>impedance matching</dc:subject><dc:subject>return loss</dc:subject><dc:subject>radiation pattern</dc:subject><dc:subject>surface current distribution</dc:subject><dc:subject>biomedical antennas</dc:subject><dc:description xml:lang="en">In this paper, microstrip dual band antenna array with defected ground structure has been proposed for low frequency wearable on-body applications. The array has been simulated with Cotton, Polyimide, Polyester and Teflon (PTFE) flexible materials which are mostly used for biomedical applications. The performance of 2x2 trapezoidal patch array with partial ground, thin slot defection at center has been studied in terms of return loss, VSWR, power handling capability, radiation pattern and surface current distribution. All substrates exhibits acceptable fractional bandwidth below -10 dB and Cotton proves its superiority than other substrates with -20 dB and -48 dB return loss with 16.12% and 7.73% bandwidth at 1.24 GHz and 1.94 GHz respectively. The proper matching of array has been proved with VSWR value below 1.3 for all substrates. The observation of input port impedance shows that, Cotton array has good impedance matching nearly to 50 Ω and PTFE array has 100 Ω poor impedance matching. The proposed four flexible array exhibit omnidirectional pattern in H plane with 1.43 dBi gain and bidirectional pattern in E plane with 1.4 dBi gain which are support for ideal fitness of proposed flexible material array for medical applications.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i1.3459</dc:identifier><dc:identifier>10.11591/eei.v11i1.3459</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 1 (2022); 346-353</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3459/2453</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>