Abstrak

The use of electrical energy increases globally every year. The laboratory prediction energy control system (LPECS) predicted energy demand. This research was conducted in the Electrical Engineering Vocational Education laboratory by comparing the artificial neural fuzzy system (ANFIS) with the fuzzy logic. The comparison of methods aimed to determine their reliability in the energy demand prediction systems. The results showed that the minimum value of the target data using the conventional method (actual data) was 44.42%. Meanwhile, the prediction data using the ANFIS method was 44.33%, and the prediction data using the fuzzy method was 59.31%. The maximum value of the conventional ways (actual data) of ANFIS and fuzzy was similar by 77.59%. The RMSE ANFIS value was 0.1355%, the mean absolute percentage error (MAPE) was 0.2791%, and the fuzzy logic was 0.1986%. Thus, the ANFIS is applicable to determine the minimum and maximum values. Meanwhile, fuzzy can only show the maximum value but cannot reach the minimum value properly.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 152 tautan kepenulisan bersama · 97 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Sultan Ageng Tirtayasa University
  • Yogyakarta State University
  • Tun Hussein Onn University of Malaysia
  • Lampung University
  • Universitas Muhammadiyah Muara Bungo
  • Universitas Negeri Padang
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sharin Ab GhaniUniversiti Teknikal Malaysia Melaka6
Imran Sutan ChairulUniversiti Teknikal Malaysia Melaka6
Mohd Shahril Ahmad KhiarUniversiti Teknikal Malaysia Melaka5
Muhammad Akhsan HakikiUniversitas Muhammadiyah Muara Bungo5
Affero IsmailTun Hussein Onn University of Malaysia4
Martias MartiasUniversitas Bina Sarana Informatika3
Dedi SetiawanUniversitas Negeri Padang3
Muhammad NurtantoSultan Ageng Tirtayasa University3
Sunardi SunardiPoliteknik Perkeretaapian Indonesia3
Radinal FadliLampung University3
Teguh FirmansyahSultan Ageng Tirtayasa University2
Muhammad Syahrani JohalUniversiti Teknikal Malaysia Melaka2
Nor Hidayah RahimUniversiti Teknikal Malaysia Melaka2
Mohamad Nazri Mohamad DinAfiliasi tidak diketahui2
Irwanto IrwantoState University of Jakarta2
Abdurrahman AbdurrahmanLampung University2
Putu SudiraYogyakarta State University2
Mochamad Bruri TriyonoYogyakarta State University2
Muhamad Aqil RizqillahSultan Ageng Tirtayasa University2
Tamil Selvan SubramaniamTun Hussein Onn University of Malaysia2
Alimuddin AlimuddinSultan Ageng Tirtayasa University1
Anggoro Suryo PramudyoSultan Ageng Tirtayasa University1
Siswo WardoyoSultan Ageng Tirtayasa University1
Mohd Zamri Che WanikUniversiti Malaysia Kelantan1
Ahmad Fitri MazlanUniversiti Teknikal Malaysia Melaka1
Mohammad Osman TokhiLondon South Bank University1
Mohamad Fani SulaimaUniversiti Teknikal Malaysia Melaka1
Elia Erwani HassanUniversiti Teknikal Malaysia Melaka1
Hanan Izzati Mohd NoorUniversiti Teknikal Malaysia Melaka1
Nazrulazhar BahamanUniversiti Teknikal Malaysia Melaka1
Gunadi GunadiUniversitas Gajayana Malang1
Siswantoyo SiswantoyoYogyakarta State University1
Indra MutiaraPoliteknik Negeri Ujung Pandang1
Jurifa Mat LaziUniversiti Teknikal Malaysia Melaka1
Leong Hui EeUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Laboratory prediction energy control system based on artificial intelligence network</dc:title><dc:creator>Desmira Desmira</dc:creator><dc:creator>Norazhar B. Abu Bakar</dc:creator><dc:creator>Mohd Ruzaini Hashim</dc:creator><dc:creator>Romi Wiryadinata</dc:creator><dc:creator>Mustofa Abi Hamid</dc:creator><dc:subject>load forecasting</dc:subject><dc:subject>adaptive neuro-fuzzy inference system</dc:subject><dc:subject>fuzzy logic</dc:subject><dc:subject>forecast accuracy comparison</dc:subject><dc:subject>energy consumption</dc:subject><dc:description xml:lang="en">The use of electrical energy increases globally every year. The laboratory prediction energy control system (LPECS) predicted energy demand. This research was conducted in the Electrical Engineering Vocational Education laboratory by comparing the artificial neural fuzzy system (ANFIS) with the fuzzy logic. The comparison of methods aimed to determine their reliability in the energy demand prediction systems. The results showed that the minimum value of the target data using the conventional method (actual data) was 44.42%. Meanwhile, the prediction data using the ANFIS method was 44.33%, and the prediction data using the fuzzy method was 59.31%. The maximum value of the conventional ways (actual data) of ANFIS and fuzzy was similar by 77.59%. The RMSE ANFIS value was 0.1355%, the mean absolute percentage error (MAPE) was 0.2791%, and the fuzzy logic was 0.1986%. Thus, the ANFIS is applicable to determine the minimum and maximum values. Meanwhile, fuzzy can only show the maximum value but cannot reach the minimum value properly.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i3.1821</dc:identifier><dc:identifier>10.11591/eei.v11i3.1821</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 3 (2022); 1280-1288</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/1821/2722</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>