Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

ECG biometric in real-life settings: analysing different physiological conditions with wearable smart textiles shirts

Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 5 (2023) · hlm. 2930–2938

DOI
10.11591/eei.v12i5.5133
ISSN
2089-3191, 2302-9285
Terbit
2023-10-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The adoption of biomedical signals such as the electrocardiogram (ECG) for biometric is rising in tandem with the increased attention to wearable devices. However, despite its potential benefits, ECG is rarely implemented as a biometric mechanism in real-life wearable applications. Therefore, this research aims to analyse the ECG signals extracted from wearable Hexoskin Proshirt for biometric authentication in different physiological conditions. A total of 11 subjects participated in this study, where the ECG signals were recorded while standing, sitting, walking, and uncontrolled activity. The raw ECG signal is first pre-processed using noise-removal butterworth filters in the time domain, followed by an efficient QRS segmented feature extraction approach. Finally, around 854 datasets were generated for training and validation, while the remaining 300 were used to test the proposed recognition method with a quadratic support vector machine (QSVM). The results show that the proposed method achieved a reliable accuracy above 98% with false acceptance rate (FAR) of 0.93%, false rejection rate (FRR) of 3.64%, and true positive rate (TPR) above 96% on the in-house datasets. This researchs findings confirm the possibility of using ECG biometrics for authentication purposes in various real-life settings with varying physiological parameters using a smart textile shirt.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 19 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • International Islamic University Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sheroz KhanInternational Islamic University Malaysia2
A. H. M. Zahirul AlamInternational Islamic University Malaysia2
Nurul Arfah Che MustaphaInternational Islamic University Malaysia2
Rashidah Funke OlanrewajuInternational Islamic University Malaysia1
Dua’a Mahmoud Al-QudahInternational Islamic University Malaysia1
Aisha Hassan Abdalla HashimInternational Islamic University Malaysia1
Samihah Abdul LatifInternational Islamic University Malaysia1
Noreha Abdul MalikInternational Islamic University Malaysia1
Nabila Husna Mohd JohariInternational Islamic University Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">ECG biometric in real-life settings: analysing different physiological conditions with wearable smart textiles shirts</dc:title><dc:creator>Muhammad Muizz Mohd Nawawi</dc:creator><dc:creator>Khairul Azami Sidek</dc:creator><dc:creator>Amelia Wong Azman</dc:creator><dc:subject>electrocardiogram biometrics</dc:subject><dc:subject>biometric authentication</dc:subject><dc:subject>physiological conditions</dc:subject><dc:subject>quadratic support vector machine</dc:subject><dc:subject>ECG signal preprocessing</dc:subject><dc:description xml:lang="en">The adoption of biomedical signals such as the electrocardiogram (ECG) for biometric is rising in tandem with the increased attention to wearable devices. However, despite its potential benefits, ECG is rarely implemented as a biometric mechanism in real-life wearable applications. Therefore, this research aims to analyse the ECG signals extracted from wearable Hexoskin Proshirt for biometric authentication in different physiological conditions. A total of 11 subjects participated in this study, where the ECG signals were recorded while standing, sitting, walking, and uncontrolled activity. The raw ECG signal is first pre-processed using noise-removal butterworth filters in the time domain, followed by an efficient QRS segmented feature extraction approach. Finally, around 854 datasets were generated for training and validation, while the remaining 300 were used to test the proposed recognition method with a quadratic support vector machine (QSVM). The results show that the proposed method achieved a reliable accuracy above 98% with false acceptance rate (FAR) of 0.93%, false rejection rate (FRR) of 3.64%, and true positive rate (TPR) above 96% on the in-house datasets. This researchs findings confirm the possibility of using ECG biometrics for authentication purposes in various real-life settings with varying physiological parameters using a smart textile shirt.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i5.5133</dc:identifier><dc:identifier>10.11591/eei.v12i5.5133</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2930-2938</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5133/3405</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>