Controlling the effectiveness of STATCOM using ANFIS based on PI controller
Bulletin of Electrical Engineering and Informatics · Vol. 12 No. 5 (2023) · hlm. 2595–2604
ISSN 2089-3191, 2302-9285
Terbit 2023-10-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This research achieves two goals, the first is the modelling of the static synchronous compensator (STATCOM) and design of the control circuits for current, voltage and d.c capacitor voltage (Vd.c) to improve the power factor (PF) by preparing the reactive power by STATCOM so that its work is similar to the work of a synchronous condenser, and the second goal is to use smart techniques to control the Vd.c loop. For comparison, smart technical methods such as fuzzy logic type 1 (FL-T1), fuzzy logic type 2 (FL-T2), and adaptive neuro fuzzy inference system (ANFIS) were used to regulate the Vd.c on the capacitor instead of the traditional controller proportional integral (PI). Simulation was performed in MATLAB 2021 to determine the efficiency of the suggested method or approach controllers for STATCOM. The use of the proposed method improves the signal value of both the current and the voltage and the phase difference between them, which reaches almost zero. Proved that an ANFIS technique provides best Vd.c response in different values of balance and unbalance load compared with the other methods by obtaining the minimum peak overshoot (P-ov) and minimum settling time (ST).
Jaringan kolaborasi para penulis
9 penulis ·
12 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Mosul University of Technology Malaysia Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Controlling the effectiveness of STATCOM using ANFIS based on PI controller</dc:title><dc:creator>Maha Abdulrhman Al-Flaiyeh</dc:creator><dc:creator>Nagham Hikmat Aziz</dc:creator><dc:creator>Saraa Ismaeel Khalel</dc:creator><dc:subject>STATCOM</dc:subject><dc:subject>adaptive neuro-fuzzy inference system</dc:subject><dc:subject>PI controller</dc:subject><dc:subject>DC capacitor voltage control</dc:subject><dc:subject>power factor correction</dc:subject><dc:subject>reactive power compensation</dc:subject><dc:subject>fuzzy logic controller</dc:subject><dc:subject>type-1 fuzzy logic</dc:subject><dc:subject>type-2 fuzzy logic</dc:subject><dc:subject>unbalanced loads</dc:subject><dc:subject>peak overshoot</dc:subject><dc:subject>settling time</dc:subject><dc:description xml:lang="en">This research achieves two goals, the first is the modelling of the static synchronous compensator (STATCOM) and design of the control circuits for current, voltage and d.c capacitor voltage (Vd.c) to improve the power factor (PF) by preparing the reactive power by STATCOM so that its work is similar to the work of a synchronous condenser, and the second goal is to use smart techniques to control the Vd.c loop. For comparison, smart technical methods such as fuzzy logic type 1 (FL-T1), fuzzy logic type 2 (FL-T2), and adaptive neuro fuzzy inference system (ANFIS) were used to regulate the Vd.c on the capacitor instead of the traditional controller proportional integral (PI). Simulation was performed in MATLAB 2021 to determine the efficiency of the suggested method or approach controllers for STATCOM. The use of the proposed method improves the signal value of both the current and the voltage and the phase difference between them, which reaches almost zero. Proved that an ANFIS technique provides best Vd.c response in different values of balance and unbalance load compared with the other methods by obtaining the minimum peak overshoot (P-ov) and minimum settling time (ST).</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v12i5.5089</dc:identifier><dc:identifier>10.11591/eei.v12i5.5089</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 12 No 5 (2023); 2595-2604</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5089/3368</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
8 sitasi
Crossref
Terindeks
lewat DOI
4 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Al-Flaiyeh, M. A., Aziz, N. H., & Khalel, S. I. (2023). Controlling the effectiveness of STATCOM using ANFIS based on PI controller. Bulletin of Electrical Engineering and Informatics, 12(5), 2595–2604. https://doi.org/10.11591/eei.v12i5.5089
Salin
IEEE
M. A. Al-Flaiyeh, N. H. Aziz, and S. I. Khalel, “Controlling the effectiveness of STATCOM using ANFIS based on PI controller,” Bulletin of Electrical Engineering and Informatics, vol. 12, no. 5, pp. 2595–2604, 2023, doi: 10.11591/eei.v12i5.5089.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.