Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The performance comparison of artificial intelligence based distance relays for the protection of transmission lines

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 3 (2022) · hlm. 1177–1185

DOI
10.11591/eei.v11i3.3305
ISSN
2089-3191, 2302-9285
Terbit
2022-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The safe and reliable generation and transmission of electricity is the desirable factor for utilities which arises the need of protection equipment such as relays in the power systems. According to recent studies, the conventional relays are not able to provide the required protection to the power systems, resulting in the emergence of various artificial intelligence (AI) techniques such as (i) artificial neural network (ANN); (ii) adaptive neuro fuzzy interface system (ANFIS); and (iii) fuzzy logic based relays for the protection. This work presents the protection scheme for transmission lines using various AI based distance relays along with performance comparison of these relays with a conventional numerical distance relay (NL). The comparison analysis has been performed by generating a test model in the MATLAB/Simulink environment and comparing “response time” against the same fault occurence for all relays. The comparison analysis found that AI based relays outperformed than conventional relay in terms of response time and accuracy level against the faults.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 27 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Engineering and Technology Lahore
  • National University of Computer and Emerging Sciences
  • Ghulam Ishaq Khan Institute of Engineering Sciences and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kashif AmjadNational University of Computer and Emerging Sciences1
Muhammad Sohaib ChoudharyUniversity of Engineering and Technology Lahore1
Muhammad Saqlain SaqiUniversity of Engineering and Technology Lahore1
Hasan Erteza GelaniUniversity of Engineering and Technology Lahore1
Muhammad AkramUniversity of Engineering and Technology Lahore1
Sana KhanGhulam Ishaq Khan Institute of Engineering Sciences and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The performance comparison of artificial intelligence based distance relays for the protection of transmission lines</dc:title><dc:creator>Muhammad Rameez Javed</dc:creator><dc:creator>Umar Siddique Virk</dc:creator><dc:creator>Aashir Waleed</dc:creator><dc:creator>Muhammad Yasir Jamal</dc:creator><dc:subject>distance relays</dc:subject><dc:subject>transmission line protection</dc:subject><dc:subject>artificial neural networks</dc:subject><dc:subject>adaptive neuro-fuzzy inference system</dc:subject><dc:subject>fault detection</dc:subject><dc:subject>response time</dc:subject><dc:description xml:lang="en">The safe and reliable generation and transmission of electricity is the desirable factor for utilities which arises the need of protection equipment such as relays in the power systems. According to recent studies, the conventional relays are not able to provide the required protection to the power systems, resulting in the emergence of various artificial intelligence (AI) techniques such as (i) artificial neural network (ANN); (ii) adaptive neuro fuzzy interface system (ANFIS); and (iii) fuzzy logic based relays for the protection. This work presents the protection scheme for transmission lines using various AI based distance relays along with performance comparison of these relays with a conventional numerical distance relay (NL). The comparison analysis has been performed by generating a test model in the MATLAB/Simulink environment and comparing “response time” against the same fault occurence for all relays. The comparison analysis found that AI based relays outperformed than conventional relay in terms of response time and accuracy level against the faults.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i3.3305</dc:identifier><dc:identifier>10.11591/eei.v11i3.3305</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 3 (2022); 1177-1185</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3305/2869</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>