Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Variations in phase conductor size and spacing on power losses on the Nigerian distribution network

Bulletin of Electrical Engineering and Informatics · Vol. 11 No. 3 (2022) · hlm. 1222–1233

DOI
10.11591/eei.v11i3.3753
ISSN
2089-3191, 2302-9285
Terbit
2022-06-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Most Nigerian distribution networks are examined on a single-phase basis, which fails to reflect the network's true features. Using three-phase power flow algorithms, this research explores the implications of variations in conductor sizes and spacing on power losses on a Nigerian network. Modified carson's equations were used to model the distribution lines to determine the network's impedance without presuming transposition of the lines. The conductor sizes and spacing were changed to see how they affected network power losses and how they contributed to the distribution network imbalance. The results showed that changing the conductor sizes of certain of the phases increased real power losses by 55.8 and 5.8%, respectively, in phases A and B. Phase C's was reduced by 13.04%. Furthermore, reactive power losses in phases A and B increased by 3.29 and 8.18%, respectively, whereas reactive losses in phase C dropped by 10.32%. Changing the conductor spacing in phases A, B, and C increased real power losses by 825.8, 136.2, and 13.2%, respectively, and reactive power losses by 72.86, 52.30, and 31.89%. Distribution networks should not be evaluated on a single-phase basis since losses differ in each of the three phases. Conductor size and spacing reductions cause huge losses.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 36 tautan kepenulisan bersama · 28 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Obafemi Awolowo University
  • Lead City University
  • University of Ilorin
  • Cape Peninsula University of Technology
  • Ladoke Akintola University of Technology
  • Olabisi Onabanjo University
  • Kwara State University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adedire Ayodeji BabatundeOlabisi Onabanjo University4
Fatina Mosunmola AremuKwara State University4
Emmanuel Idowu OgunwoleCape Peninsula University of Technology3
Abdullahi AremuAfiliasi tidak diketahui3
Dolapo Eniola OwolabiLadoke Akintola University of Technology3
Moses Taiwo AdebayoObafemi Awolowo University3
Ayodeji Olalekan SalauAfe Babalola University1
Sepiribo Lucky BraideRivers State University1
Tayo Uthman BadrudeenOduduwa University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Variations in phase conductor size and spacing on power losses on the Nigerian distribution network</dc:title><dc:creator>Abdulrasaq Jimoh</dc:creator><dc:creator>Samson Oladayo Ayanlade</dc:creator><dc:creator>Funso Kehinde Ariyo</dc:creator><dc:creator>Abdulsamad Bolakale Jimoh</dc:creator><dc:subject>power losses</dc:subject><dc:subject>conductor size</dc:subject><dc:subject>conductor spacing</dc:subject><dc:subject>three-phase power flow</dc:subject><dc:subject>reactive power loss</dc:subject><dc:subject>real power loss</dc:subject><dc:subject>unbalanced distribution systems</dc:subject><dc:description xml:lang="en">Most Nigerian distribution networks are examined on a single-phase basis, which fails to reflect the network's true features. Using three-phase power flow algorithms, this research explores the implications of variations in conductor sizes and spacing on power losses on a Nigerian network. Modified carson's equations were used to model the distribution lines to determine the network's impedance without presuming transposition of the lines. The conductor sizes and spacing were changed to see how they affected network power losses and how they contributed to the distribution network imbalance. The results showed that changing the conductor sizes of certain of the phases increased real power losses by 55.8 and 5.8%, respectively, in phases A and B. Phase C's was reduced by 13.04%. Furthermore, reactive power losses in phases A and B increased by 3.29 and 8.18%, respectively, whereas reactive losses in phase C dropped by 10.32%. Changing the conductor spacing in phases A, B, and C increased real power losses by 825.8, 136.2, and 13.2%, respectively, and reactive power losses by 72.86, 52.30, and 31.89%. Distribution networks should not be evaluated on a single-phase basis since losses differ in each of the three phases. Conductor size and spacing reductions cause huge losses.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2022-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v11i3.3753</dc:identifier><dc:identifier>10.11591/eei.v11i3.3753</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 11 No 3 (2022); 1222-1233</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/3753/2689</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>